Definition of Inrush Current, Start up Time and Hold Time

Overload Protection

The Power supply is provided with an overload protection function 
that protect the load and the power supply from possible damage by 
over current. When the output current rises above between 105 to 
130% (105 to 120% for the 40 A model) of the rated current, the 
protection function is triggered, decreasing the output voltage. When 
output current falls within the rated range, the overload protection 
function is automatically cleared.

De-rating Curve

For UL and CSA the maximum temperature is 60°C 
(70°C for the 20 A model)

Overvoltage Protection

5 A and 10 A models

If output voltage exceed the rated voltage more than 25% (50% at 
maximum) by some reason, then the  output voltage will be 
automatic limited for safety.

20 A and 40 A models

If output voltage exceed the rated voltage more than 25% (50% at 
maximum) by some reason, then the output voltage will be turned 
OFF automatically for safety. To restart the S8VT, turn OFF the input 
voltage, wait few minutes, then apply the input power again.