S82K
S82K
16
Installation
S82K-015
S82K-030
/
S82K-05024
S82K-09024/
S82K-10024
S82K-003
/
S82K-007
(Single Output)
6
7
5
1
2
3
DC–12V
DC+12V
1
1
2
3
7
5
6
7
5
1
2
3
S82K-007
(Dual outputs)
1
5
7
6
2
3
1
8
5
7
6
2
3
4
1.
DC Output Terminals: Connect the load lines to these terminals.
2.
Input Terminals: Connect the input lines to these terminals.
3.
Ground Terminal (GR): Connect a ground line to this terminal.
4.
Input Voltage Selector Terminals: Selects a 100 V or 200 V input voltage.
5.
Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON.
6.
Output Voltage Adjuster(V.ADJ): It is possible to increase or decrease the output volt-
age.
7.
Undervoltage Alarm Indicator (DC LOW): All models except S82K-24024 and
S82K-P24024.
8.
Undervoltage Alarm Output (DC LOW): S82K-09024/S82K-10024/S82K-24024T
models only.
9.
Parallel/Single Operation Selector: Set to “PARALLEL” for parallel operation.