background image

Switching Power Supply

S82K

DIN-Rail Mount Power Supply with a
Wide Power Range of 3 to 240 W

Universal voltage range: 100 to 
240 VAC

UL 508 listed on all models

Class 2 approved on all models below
240-W, except dual-output types

Undervoltage indicators on all.
90-W, 100-W and 240-W T-Models have
indicator and output

Meets EN61000-3-2 (limits for harmonic
current emissions) with PFC on 240-W
models

Parallel operation capability (90-W, 
100-W and 240-W)

Finger-safe terminal block with cover
according to VDE0106/P100

Approvals: UL, CSA, VDE, and CE

3-year warranty

u

R

Ordering Information

SWITCHING POWER SUPPLIES

Rated input voltage

Power ratings

Output voltage

Output current

Functional configuration

Part number

100 to 240 VAC

3 W

5 V

0.6 A

Single output

S82K-00305

12 V

0.25 A

g

S82K-00312

15 V

0.2 A

S82K-00315

24 V

0.13 A

S82K-00324

7.5 W

5 V

1.5 A

S82K-00705

12 V

0.6 A

S82K-00712

15 V

0.5 A

S82K-00715

24 V

0.3 A

S82K-00724

+12 V/–12 V

0.3 A/0.2 A

Dual output

S82K-00727

+15 V/–15 V

0.2 A/0.2 A

S82K-00728

15 W

5 V

2.5 A

Single output

S82K-01505

12 V

1.2 A

S82K-01512

24 V

0.6 A

S82K-01524

30 W

5 V

5.0 A

S82K-03005

12 V

2.5 A

S82K-03012

24 V

1.3 A

S82K-03024

50 W

24 V

2.1 A

S82K-05024

(This table continues on the next page.)

Summary of Contents for S82K

Page 1: ...00 Approvals UL CSA VDE and CE 3 year warranty uR Ordering Information SWITCHING POWER SUPPLIES Rated input voltage Power ratings Output voltage Output current Functional configuration Part number 100...

Page 2: ...7 7 5 W 015 15 W 030 30 W 050 50 W 090 90 W 100 100 W S82K 1 2 2 Output Voltage 05 5 VDC 12 12 VDC 15 15 VDC 24 24 VDC 27 Dual output 12 12 VDC 28 Dual output 15 15 VDC 240 W Models 3 to 100 W Models...

Page 3: ...3 Hz Current see 3 100 V input 0 15 A max 0 25 A max 0 45 A max 0 9 A max 1 3 A max 2 5 A max 5 5 A max 4 A max see note 3 200 V input max 0 25 A max 0 6 A max 0 8 A max 1 5 A max 3 5 A max 2 A max Po...

Page 4: ...ence see note 1 0 05 C max Rise time 100 ms max up to 90 of output voltage at rated input and output 200 ms max 300 ms max 1 000 ms max Hold time see note 1 20 ms min This table continues on the next...

Page 5: ...output DC LOW output No Yes S82K 24024T model only No Parallel operation Impossible Possible 2 units max This table continues on the next page Note 1 Defined with a 100 load and the rated input voltag...

Page 6: ...d optional filter see note 3 240 W Models EMI EN50081 2 Emission Enclosure EN55011 class A see note 4 Emission AC Mains EN55011 class A see note 4 Harmonic Current EN61000 3 2 only for S82K P24024 Com...

Page 7: ...ent temperature C 3 7 5 15 30 50 90 W 100 W Models 240 W Model Parallel Unit Operation Note 100 V input 85 to 132 VAC Load Ambient temperature C S82K P24024 100 VAC input see note Load Ambient tempera...

Page 8: ...l circuitry do not short circuit the output terminals of the S82K or use the S82K with excessive output current for a long time Output voltage V Output current Rated voltage 3 7 5 15 90 W 100 240 W Mo...

Page 9: ...LOW output This function detects the voltage at the output terminal of the Power Supply To check the precise output voltage measure the voltage at the terminal of the load Indicator Voltage Operation...

Page 10: ...07 7 5 W Dual Outputs Fuse 1 A Noise filter Inrush current protection circuit Rectifier Drive control circuit Photocoupler AC L AC N Rectifier V V Rectifier Undervoltage alarm indicator 3 terminal REG...

Page 11: ...1 Photocoupler INPUT AC L AC N Overload alarm circuit Rectifying and smoothing circuit Overvoltage alarm circuit Detector GR Rectifier DC LOW Undervoltage alarm indicator output See Note 3 Note 1 The...

Page 12: ...ets Supplied with the Power Supply Two 4 5 dia 35 25 Used when not mounting the Power Supply directly on the DIN rail L See Note 27 4 6 sliding 7 max 75 2 95 37 5 1 48 9 8 8 3 65 2 56 35 45 4 58 1 S82...

Page 13: ...mm min between each adjacent Power Supply 91 3 58 90 3 54 80 58 1 75 2 95 60 45 35 2 7 5 5 S82K 09024 90 W S82K 10024 100 W 60 2 36 135 5 31 L See Note Four M4 or 4 5 dia mounting holes 58 1 75 2 95 4...

Page 14: ...s Note If more than one Power Supply is installed in a row keep a distance of 20 mm min L 20 mm min between each adjacent Power Supply Four M4 or 4 5 dia mounting holes 130 5 12 Four 4 5 dia 100 3 94...

Page 15: ...00N2 15 5 See Note Note The values shown in parentheses are for the PFP 50N 12 25 x 4 5 oblong Noise Filter Order Separately 39 16 max A B Two 4 8 dia Mounting holes D 6 5 4 Six M4 6 5 C 16 max 4 Name...

Page 16: ...Ground Terminal GR Connect a ground line to this terminal 4 Input Voltage Selector Terminals Selects a 100 V or 200 V input voltage 5 Output Indicator DC ON Lights while a Direct Current DC output is...

Page 17: ...input voltage 5 Output Indicator DC ON Lights while a Direct Current DC output is ON 6 Output Voltage Adjuster V ADJ It is possible to increase or decrease the output voltage 7 Undervoltage Alarm Ind...

Page 18: ...in the following illustration Forced air cooling is recommended 20 mm min To mount the Power Supply on a DIN rail hook portion A of the Power Supply to the rail and press the Power Supply toward dire...

Page 19: ...wer Supply so there will be no difference in output voltage between each Power Supply If the 240 W Power Supply is used in single operation un der the parallel operation setting the overcurrent protec...

Page 20: ...t notice Printed in U S A OMRON ELECTRONICS INC One East Commerce Drive Schaumburg IL 60173 NOTE DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters to inches divide by 25 4 1 800 55 OMRON OMRO...

Reviews: