10 Operation
10 - 6
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Turn ON the control circuit power after you conduct the pre-power-ON checking.
It is indifferent whether you turn On or OFF the main circuit power.
The 7-segment display is on the front panel.
When the power is turned ON, it shows the node address that is set by the rotary switches. Then the
display changes according to the setting of the LED Display Selection (3700 hex).
An error code is displayed if an error occurs. A warning code is displayed if a warning occurs.
10-2-2 Turning ON the Power Supply
10-2-3 Checking the Displays
7-Segment Display
A
Control power ON
Fully OFF
Fully ON
“nA” (node address, approx. 0.6 s)
Rotary switch setting
(upper digit (×10) = 0, lower digit (×1) = 3)
(It lasts for the period set in the Power ON
Address Display Duration Setting (3701 hex).)
Node Address Display
To
on the next page