5-74
5-16 User Parameters
5
Ope
rati
ng Func
tions
(Pn39) are effective as absolute values (positive/negative).
• Use this parameter to set the speed for jog operation.
• Before use, refer to
Position Control Parameters (Pn40 to Pn4E)
Explanation of Settings
• Use this parameter to select whether to use photocoupler or line-driver input for the command
pulse input.
• When using a Servo Relay Unit cable, set to 0 (photocoupler input).
Explanation of Settings
• Use this parameter to set the Servomotor rotation direction used for the command pulse input.
Pn3D
Jog Speed
Setting range
0 to 500
Unit
r/min
Default setting
200
Power OFF
→
ON
---
Pn40
Command Pulse Input Selection
Setting range
0 or 1
Unit
---
Default setting
0
Power OFF
→
ON
Yes
Setting
Explanation
0
Photocoupler input (+PULS: CN1 pin 3,
−
PULS: CN1 pin 4, +SIGN: CN1 pin 5,
−
SIGN: CN1 pin 6)
1
Line driver input (+CWLD: CN1 pin 44,
−
CWLD: CN1 pin 45, +CCWLD: CN1 pin 46,
−
CCWLD: CN1 pin 47)
Pn41
Command Pulse Rotation Direction Switch
Setting range
0 or 1
Unit
---
Default setting
0
Power OFF
→
ON
Yes
Setting
Explanation
0
The Servomotor rotates in the direction specified by the command pulse.
1
The Servomotor rotates in the opposite direction from the direction specified by the
command pulse.
All modes
Position
Position
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...