Frequency inverters

R1000 kit - Regenerative Braking unit system

Regenerative Braking unit (R1000)

Current suppression reactor

Reference:
CIMR-RC

@

4A03P5 4A0005 4A0007 4A0010 4A0014 4A0017 4A0020 4A0028 4A0035 4A0043 4A0053 4A0073 4A0105 4A0150 4A0210 4A0300

Max. applicable
motor capacity (kW)

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

110

160

220

315

Rated output
capacity (kW)

*

1

*

1. Rated output capacity is calculated with a rated input voltage of 400 V.

3.5

5

7

10

14

17

20

28

35

43

53

73

105

150

210

300

Rated input current 
AC (A)

5

8

11

16

22

27

32

43

54

66

81

110

161

237

326

466

Rated output current 
DC (A)

7

11

15

22

30

36

43

58

73

89

109

149

217

320

440

629

Rated input voltage

3-phase 380 to 480 VAC

Rated frequency

50/60 Hz

Power factor

> 0.9 at full load

Degree of protection IP20

IP00

Ambient humidity

95% RH or less (without condensation)

Storage temperature -20 to 60ºC
Ambient temperature -10 to 50ºC

Reference: B150

@

9105

9106

9107

9108

9109

9110

4118

9111

9112

9113

9114

5002

5008

5011

Rated current (A)

7.5

10

15

25

30

40

50

60

75

100

161

237

326

466

Inductance (mH)

1.2

0.6

0.4

0.3

0.2

0.15

0.12

0.1

0.08

0.06

0.04

0.03

0.02

0.013

Heat  loss  (W)

21

19

23

36

33

40

46

56

81

72

95

105

120

160

Motor

Power 
supply

Q2A

Regeneretive 
braking unit (R1000)

Current suppression
reactor

AC input
reactor

R1000 kit

I175E-EN-01+Q2A+Datasheet.fm  Seite 20  Montag, 26. März 2018  3:18 15

Summary of Contents for Q2A Series

Page 1: ...Bluetooth Regenerative solutions as option CE UL cUL EAC RoHS Ratings 400 V class 0 55 to 315 kW System configuration LCD Remote Installation Remote Operator Extansion Cable Mounting Bracket MCCB Q2A Filter Input AC Reactor Motor Ground Power Supply Braking Resistor DC Reactor Feedback Speed Option Card Input Output Option Card Choke Output AC Reactor or Braking chopper R1000 kit 2 Regenerative so...

Page 2: ... 11 14 21 27 34 40 52 65 Overload tolerance 5 HD 150 of the rated output current for 60 seconds ND 110 of the rated output current for 60 seconds Carrier frequency 6 without derating the drive capacity HD 8 kHz ND 2 kHz Max output voltage Proportional to input voltage 380 480 V Max output frequency AOLV EZOLV 120 Hz CL V f CLV AOLV PM CLV PM 400 Hz V f OLV OLV PM 590 Hz Power supply Rated voltage ...

Page 3: ...or ratings as specified in NEC Table 430 250 The rated output current of the drive output amps must be equal to or more than the motor rated current 3 The rated output capacity is calculated with a rated output voltage of 380 V 4 The rated output capacity is calculated with a rated output voltage of 460 V 5 Derating may be necessary for applications that start and stop frequently 6 Derate the driv...

Page 4: ... loss is shorter than 2 s depending on parameter settings Stop time may be shortened depending on the load and motor speed Drive capacity will change the continuous operation time A momentary power loss recovery unit is necessary to continue operation through a 2 s power loss on models 4002 to 4031 Heatsink overheat Protected by thermistor Stall prevention Stall prevention is available during acce...

Page 5: ... 4060 246 106 4075 4 240 195 186 12 400 375 17 5 17 5 280 166 114 4089 4103 5 255 170 165 450 424 16 29 21 4140 4168 6 264 190 182 543 516 17 5 28 5 20 5 335 186 149 M8 4208 4250 4296 7 312 218 218 18 700 659 28 43 5 28 5 420 260 160 4 5 4 5 M10 4371 4389 8 440 370 370 20 800 757 44 30 472 254 218 M12 4453 4568 4675 9 510 450 450 1140 1093 25 5 43 5 30 5 480 260 220 Figure 1 Figure 2 Figure 3 Figu...

Page 6: ...A B1 B2 C1 C2 D E F 400 V AX RAI07700042 DE 120 70 120 80 52 5 5 1 78 AX RAI07700050 DE AX RAI03500090 DE 80 62 2 35 AX RAI03500100 DE AX RAI01300170 DE 180 75 195 140 55 6 5 5 AX RAI00740335 DE 85 190 AX RAI00360500 DE 205 6 5 AX RAI00290780 DE 105 75 11 2 AX RAI00191150 DE 240 110 275 200 16 0 AX RAI00111850 DE AX RAI00072700 DE 180 210 110 25 4 AX RAI00043350 DE 140 85 18 6 AX RAI00034500 DE 16...

Page 7: ...120 80 120 80 62 5 5 2 35 AX RAO11800053 DE AX RAO07300080 DE 180 85 195 140 55 6 5 5 AX RAO04600110 DE AX RAO03600160 DE 210 6 5 AX RAO02500220 DE 95 65 9 1 AX RAO02000320 DE 240 110 275 200 75 16 0 AX RAO01650400 DE AX RAO01300480 DE AX RAO00800750 DE 120 281 85 18 6 AX RAO00680900 DE 150 110 27 0 AX RAO00531100 DE 300 125 350 105 27 9 AX RAO00401490 DE 170 270 125 44 0 AX RAO00331760 DE AX RAO0...

Page 8: ... H X Y m AX FER2102 RE 21 2 2 85 22 46 70 5 0 1 AX FER2515 RE 25 15 105 25 62 90 5 0 2 AX FER5045 RE 50 45 150 50 110 125 30 5 0 7 AX FER6055 RE 60 55 200 65 170 180 45 6 1 7 X H Y W Ø m L Ø d 65 106 16 8 2 1 6 53 8 min 15 44 78 2 M3 I175E EN 01 Q2A Datasheet fm Seite 8 Montag 26 März 2018 3 18 15 ...

Page 9: ...83 260 535 110 34 4A0100 36 4A0130 500 800 350 370 773 13 130 M12 85 4A0185 4A0270 370 1140 370 440 1100 15 150 183 4A0370 194 Reference Fig Dimensions mm Weight kg W H D B84143A0020R106 1 386 200 202 0 6 B84143A0035R106 426 250 322 0 9 B84143A0065R106 436 310 432 1 9 B84143B0180S080 200 170 110 5 0 B84143B0400S080 2 290 190 116 7 5 B84143B1000S080 300 260 140 18 5 D1 H H1 H2 d W1 W D Figure 1 Fig...

Page 10: ...25 69 B84143G0210S176 Harmonic filter 3a 206 3 438 300 39 10 choke 3b max 400 max 445 max 420 98 B84143G0300S176 Harmonic filter 3a 216 3 437 300 42 10 choke 3c max 550 max 490 max 440 149 B84143G0410S176 3 choke 4a 218 3 440 2 5 300 45 Capacitor 4b 281 327 200 12 10 choke 4c 401 max 450 430 163 B84143G0560S176 3 choke 4a 243 3 430 2 5 300 55 Capacitor 4b 409 379 307 25 10 choke 4c 351 3 max 590 m...

Page 11: ...0 365 197 192 350 355 15 78 M6 8 4A0020 4A0028 4A0035 3 IP00 275 450 258 220 435 7 5 100 2 3 M6 20 4A0043 4A0053 325 550 283 260 535 110 33 4A0073 4A0105 4 450 705 330 325 680 13 130 3 2 M10 62 4A0150 4A0210 500 800 350 370 773 4 5 M12 86 4A0310 87 W1 1 5 H H1 H2 W D D1 t1 4 d Figure 1 Figure 2 H2 W1 1 5 H H0 H1 W D1 D t1 H3 4 d W1 4 d H1 H H2 Max 10 W t1 t1 D1 D Figure 3 Max 10 D1 D t1 H1 H2 H 4 ...

Page 12: ...85 max 125 102 160 3 6 9 B1509114 max 140 122 10 8 B1505002 6 220 max 115 90 205 4 17 0 B1505008 230 max 140 107 215 5 22 0 B1505011 240 max 150 120 235 29 0 Figure 6 earth connector M8 B1 B C D A 4 mm terminal 2 earth terminal 6 3x0 8 Figure 1 A B C Figure 2 A C B1 B 16 mm terminal 2 earth screw M5x10 with lockwasher and washer Figure 3 A B B1 C 35 mm terminal 2 earth screw M5x10 with lockwasher ...

Page 13: ... 2 AX REM00K2200 IE AX REM00K4075 IE 200 189 0 425 AX REM00K5120 IE 260 249 0 58 AX REM00K9070 IE 2 200 61 100 74 5 216 40 230 1 41 AX REM01K9070 IE 3 365 73 105 350 70 4 AX REM03K5035 IE 4 365 100 240 350 210 8 AX REM19K0020 IE 5 206 350 140 190 50 8 1 AX REM19K0030 IE AX REM38K0012 IE 306 290 14 5 W1 4 d H H1 D D1 t1 W H2 W Max W2 Max W2 W1 D t1 D1 t2 4 d H H1 H2 Fig 2 Fig 1 168 13 45 20 182 AX ...

Page 14: ...t V DIP switch S1 2 AI2 voltage current I DIP switch S1 1 AI1 voltage current V V I FM AM V I V I V I AI PTC OFF ON FU FV FW Cooling fan M r1 s1 t1 U V W M Shielded wire PG Monitor signal phase A B pulse monitor signal Fault relay output 250 VAC max 1 A 30 VDC max 1 A min 5 VDC 10 mA MFDO During Run 250 VAC max 1 A 30 VDC max 1 A min 5 VDC 10 mA MFDO Zero Speed 250 VAC max 1 A 30 VDC max 1 A min 5...

Page 15: ...FDI selection 7 Jog command DI8 MFDI selection 8 Baseblock command N O D0V 1 MFDI power supply 0 V MFDI power supply 24 V max 150 mA DIC MFDI selection common D24V1 MFDI power supply 24 VDC Safe Disable input H1 Safe Disable input 1 Remove the jumper between H1 HC and H2 HC terminals to use the Safe Disable input 24 V 6 mA ON Normal operation OFF Coasting motor Internal impedance 4 7 kΩ Minimum OF...

Page 16: ...e control circuit keypad and option board 21 6 to 26 4 VDC 700 mA A0V External 24 V power supply ground 0 V MEMOBUS Modbus 4 RS485 Communication input output MEMOBUS Modbus communication protocol Use an RS 485 cable to connect the inverter Maximum 115 2 kbps RS485 Communication output A0V Shield ground 0 V 1 Do not close the circuit between D24V and D0V terminals Failure to obey will cause damage ...

Page 17: ... 1024 2835 3859 4568 453 1086 3035 4121 477 1183 3329 4512 4675 605 1328 3995 5323 Inverter model Q2A A Normal Duty ND 460 V Normal Duty ND 460 V Ratedoutput current A Carrier frequency kHz Interior unit loss W Cooling fin loss W Total loss W Ratedoutput current A Carrier frequency kHz Interior unit loss W Cooling fin loss W Total loss W 4002 2 1 2 39 16 55 2 1 2 39 16 55 4004 4 1 44 33 77 3 42 25...

Page 18: ... 2 to 3 0 AX RC06400116 DE 11 6 6 4 3 7 AX RC04410167 DE 16 7 4 41 5 5 AX RC03350219 DE 21 9 3 35 7 5 AX RC02330307 DE 30 7 2 33 11 0 to 15 0 AX RC01750430 DE 43 0 1 75 400 V class Max applicable motor output kW 1 1 The motor sizes are for heavy duty applications Reference Current value A Inductance mH 0 55 AX RAO16300038 DE 3 8 16 3 0 75 AX RAO11800053 DE 5 3 11 8 1 5 AX RAO07300080 DE 8 0 7 3 2 ...

Page 19: ...ient humidity 95 RH or less without condensation Storage temperature 20 to 60ºC Ambient temperature 10 to 50ºC Reference B84143 A0020R106 A0035R106 A0065R106 B0180S080 B0400S080 B1000S080 Rated current A 20 35 65 180 400 1000 Leakage current mA 3 1 3 4 3 4 21 21 40 Rated voltage 300 520 VAC Rated frequency 50 60 Hz Rated temperature 50ºC Degree of protection IP20 Reference B84143G 0008R176 0016R17...

Page 20: ...ed output current DC A 7 11 15 22 30 36 43 58 73 89 109 149 217 320 440 629 Rated input voltage 3 phase 380 to 480 VAC Rated frequency 50 60 Hz Power factor 0 9 at full load Degree of protection IP20 IP00 Ambient humidity 95 RH or less without condensation Storage temperature 20 to 60ºC Ambient temperature 10 to 50ºC Reference B150 9105 9106 9107 9108 9109 9110 4118 9111 9112 9113 9114 5002 5008 5...

Page 21: ...30 52 37 74 9 37 65 Q2A A4075 AAA 37 75 37 65 45 89 2 45 77 Q2A A4089 AAA 45 91 45 77 55 103 55 96 Q2A A4103 AAA 55 112 55 96 75 140 75 124 Q2A A4140 AAA 75 150 75 124 90 168 90 156 Q2A A4168 AAA 90 180 90 156 110 208 110 180 Q2A A4208 AAA 110 216 110 180 132 250 150 240 Q2A A4250 AAA 132 260 150 240 160 296 185 302 Q2A A4296 AAA 160 304 185 302 200 371 220 361 Q2A A4371 AAA 200 371 220 361 220 38...

Page 22: ...AX RAI01300170 DE 4296 AX RAI00043350 DE 4018 4023 4031 AX RAI00740335 DE 4371 4389 AX RAI00034500 DE 4038 4044 AX RAI00360500 DE 4453 AX RAI00025350 DE 400 V Model Q2A A DC Reactor Model Q2A A DC Reactor 4002 4004 AX RC43000020 DE 4018 AX RC03350219 DE 4005 AX RC10100069 DE 4023 AX RC02330307 DE 4007 4009 AX RC06400116 DE 4031 4038 AX RC01750430 DE 4012 AX RC04410167 DE 400 V Model Q2A A Output A...

Page 23: ...insulated Input current 8 mA DO A3 Digital output To output insulated digital signals and monitor the operation status of the drive alarm signals and detecting zero speed Photocoupler relays 6 channels 48 V 50 mA max Relay contact 2 channels 250 VAC at 1 A or less 30 VDC at 1 A or less Feedback speed option cards PG B3 1 1 This option card can only be used with CL V f and OLV control methods Motor...

Page 24: ...0 CIMR DC4A0270AAA B84143B1000S080 B84143G0410S176 D1KIT40270AAAAB 370 CIMR DC4A0370AAA B84143G0560S176 D1KIT40370AAAAB Rated power kW R1000 kit Regenerative braking unit R1000 1 1 It is not possible to purchase the Regenerative braking unit R1000 and current suppression reactor as a separate items Current suppression reactor 1 1 Kit code 3 5 CIMR RC4A03P5FAA B1509105 R1KIT40003AAAAA 5 CIMR RC4A00...

Page 25: ...00W 70Ω 1 4023 HD 11 4023 ND 4031 HD 20 15 4031 ND AX REM01K9070 IE 1900W 70Ω 1 4038 HD 18 5 4038 ND AX REM03K5035 IE 3500W 35Ω 1 4044 HD 19 2 22 4044 ND 4060 HD 30 4060 ND AX REM19K0030 IE 19000W 30Ω 1 4075 HD 37 4075 ND 4089 HD 2 10 6 45 4089 ND 4103 HD 8 7 55 4103 ND 4140 HD AX REM38K0012 IE 38000W 12Ω 1 7 2 75 4140 ND 4168 HD AX REM19K0020 IE 19000W 20Ω 3 5 2 90 4168 ND 4208 HD CDBR 4045D 2 12...

Page 26: ...ations are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No I175E EN 01 I175E EN 01 Q2A Datasheet fm Seite 26 Montag 26 März 2018 3 18 15 ...

Reviews: