Configuring the PROFIBUS-DP network
Section 2-6
• Select the I/O module that needs to be added in the Available Modules
list, and double-click it with the left mouse button. If more than one mod-
ule must be added, repeat this step for the other modules.
• Select the I/O module that needs to be added in the Available Modules
list, and press either the
Insert
or
Append
button.
Note
1.
When pressing the
Insert
button, the selected I/O module will be inserted
above the selected module in the Configured Modules list.
2.
The selected I/O modules are sent to the slave device, in the same se-
quence as selected in the user interface. The sequence determines the
target Temperature Controller / R88A-MCW151-E for the I/O data. For ex-
ample, the I/O data of the first selected Fixed Communication Block will be
sent to the first temperature Controller
3.
A mandatory I/O module sequence is sometimes indicated in the GSD file,
by using non-PROFIBUS standard GSD file keywords (i.e. only interpreted
by a specific configurator). The Generic Slave DTM does not check such
keywords. In this case, refer to the manual of the specific device for details.
4.
Also in this window are the maximum values, which can be set, and the to-
tals of I/O data that actually have been set. If - while selecting I/O modules
- one of the maximum values is exceeded, a warning message will be dis-
played.
Removing I/O Modules
To remove I/O modules from the Configured Modules list, perform one of the
following procedures.
• Select the I/O module that needs to be removed from the Configured
Modules list, and double-click it with the left mouse button. If more than
one module must be added, repeat this step for the other modules.
• Select the I/O module that needs to be removed from the Configured
Modules list, and press the
Remove
button.