![background image](http://html1.mh-extra.com/html/omron/powli-bu100sw/powli-bu100sw_instruction-manual_744602052.webp)
BU
50
SW / BU
75
SW / BU
100
SW / BU
150
SW
39
1
2
3
4
5
6
7
8
9
10
■
UPS monitoring software
All models include “PowerAct Pro” for Windows/Linux, and “UPS Service Driver” for Windows in the CD
as UPS monitoring software. Choose a suitable program depending on your usage purpose. Refer to
the attached “Quick Installation Guide.”
* If you do not use the UPS monitoring software and contact signal, this step is
not required.
For details about each software function, refer to "Reference E. List of UPS monitoring software
functions" on page 60.
See also
Using the UPS monitoring software
and contact signal
7
7
Note 1: The most recent version can be downloaded from our homepage (http://www.omron.co.jp/ese/).
Note 2: Files cannot be automatically saved.
Note 3: To automatically stop the UPS, it may be necessary to change the PC’s BIOS settings.
Change the PC’s BIOS settings so that the PC’s power supply is not cut after OS shutdown is performed.
Note 4: The UPS automatically stops once the battery is depleted.
Note 5: Compatible only with Macintosh computers equipped with PowerPC CPU.
Model
OS
Communication method
UPS monitoring software
Required options
(sold separately)
Reference
BU50SW/
BU75SW/
BU100SW/
BU150SW
Windows Vista
Serial (RS232C)
PowerAct Pro (Note 1)
–
⇒
See 7-1
Windows server2003
x64 Edition
Windows XP/2000
x64 Edition
Serial (RS232C)
PowerAct Pro (Note 1)
–
⇒
See 7-1
UPS service (OS standard) + UPS
service driver (included software)
–
⇒
See 7-2
Contact signal (Note 2) (Note 4) UPS service (OS standard)
BUC26
⇒
See 7-3
LAN
Shutdown software for SNMP/web
card
SC20G
⇒
See 8-1
Windows server2003
Windows XP/2000
Serial (RS232C)
PowerAct Pro (Note 1)
–
⇒
See 7-1
UPS service (OS standard) + UPS
service driver (included software)
–
⇒
See 7-2
Contact signal (Note 2) (Note 4) UPS service (OS standard)
BUC26
⇒
See 7-3
LAN
Shutdown software for SNMP/web
card
SC20G
⇒
See 8-1
Windows NT 4.0
Contact signal (Note 2) (Note 3) UPS service (OS standard)
BUC26
⇒
See 7-3
LAN
Shutdown software for SNMP/web
card
SC20G
⇒
See 8-1
Windows Me/98
Serial (RS232C)
PowerAct Pro (Note 1)
–
⇒
See 7-1
Linux (Note:
4
)
Serial (RS232C)
PowerAct Pro (Note 1)
–
⇒
See 7-1
LAN
Shutdown software for SNMP/web
card
SC20G
⇒
See 8-1
Mac OS X (10.3, 10.4)
Mac OS X Server
(10.3, 10.4)
LAN
Shutdown software for SNMP/web
card (Note 5)
SC20G
⇒
See 8-1
When this product is used in compliance with CE marking, please use under 3m
connection cable.
Caution