5
NL
Dimensions
(Unit: mm)
Built-in Antenna Models
Separated Antenna Models
The dimensions provided for the NL1-SP, NL2-SP, NL1-SC, and NL2-SC are the external dimensions for the antennas. The casing
dimensions of these models are all the same as those for the coil spring or plunger models.
Note: Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
1.2 dia. *1
5.3 dia.
25.8
16
15
5
7-dia. Connection
cable (1 m)
8
12.5
1
30
15
40
±
0.8
110
±
2
43.7
±
0.8
30
±
0.2
6.5
±
0.8
Two,
5.3
±
0.12
dia.
holes
Two, 5.3-dia.
long holes
(7.3)
*2
Caution label
LED operation
indicator
(15)
55
60
±
0.2
75
25 max.
*1. The coil spring antenna is movable in any direction. Make sure
that the angle of the antenna is within 30
°
to the FP (free position)
after the antenna comes into contact with the object.
*2. Use after removing the caution label.
16
(99)
75
8
1
12.5
5 *2
31
5
15
40
+0.8
30
+0.2
Two, 5.3-dia.
long holes
(7.3)
6 dia. *1
7-dia. Connection
cable (1 m)
25 max.
15
30
43.7
+0.8
60
±
0.2
Two,
5.3
+
0.12
dia.
holes
*3
Caution label
*1. The stainless-steel plunger antenna allows a maximum
OT (overtravel) of 5 mm.
*2. This position is the FP (free position) of the plunger.
*3. Use after removing the caution label.
Coil Spring
NL1-C
NL2-C
NL3-C
Plunger
NL1-P
NL2-P
NL3-P
Note: 1. The force that pushes the actuator must not exceed 1.96 N.
2. The antenna is replaceable. Contact your OMRON representative for
details.
Note: Do not apply a force greater than 9.8 N to the plunger.
40.5
±
2
1.2 dia. *1
*2
90.5
±
2
(10.5)
31
22.5
8
6
3.5
*1. The coil spring antenna is movable in any
direction. Make sure that the angle of the
antenna
is
within
30
°
to the FP (free position)
after the antenna comes into contact with the
object.
*2. A standard 3-m high-frequency coaxial
cable is provided.
*1
6 dia.
Two, M22 x 1
mounting nuts
Distance to
opposite side: 26
thickness: 4
(
)
(2.3R)
5 *2
16
±
0.2
35
±
0.5
*3
*1. The stainless-steel plunger antenna
allows a maximum OT (overtravel)
of 5 mm.
*2. This position is the FP
(free position) of the plunger.
*3. A standard 3-m high-frequency
coaxial cable is provided.
R16
51
t 2.3
12
20
32
4.5
16
35
(10.5)
31
22.5
8
6
Plunger Antenna
NL1-SP
NL2-SP
Coil Spring Antenna
NL1-SC
NL2-SC
No Antenna
NL1-S
NL2-S
Note: 1. Make sure that the shape of the antenna is suitable to the application.
Use the plunger antenna or coil spring antenna as shown right for the
NL1-S or NL2-S.
2. Do not cut or extend the connecting cable.
Note: 1. Do not apply a force greater than 9.8 N to the plunger.
2. Do not cut or extend the connecting cable.
Note: 1. Do not cut or extend the connecting cable.
2. The antenna is replaceable. Contact your OMRON representative for
details.
7 dia. *1
LED operation
indicator
Two, 5.3-dia.
long holes
(7.3)
16
15
30
(95)
75
8
1
(27)
25 max.
5
15
7-dia. Connection
cable (1 m)
Two,
5.3
±
0.12
dia.
holes
*2
Caution label
60
±
0.2
43.7
±
0.8
40
±
0.8
30
±
0.2
*1. A standard 3-m high-frequency coaxial cable is provided.
*2. Use after removing the caution label.