Specifications

NE1A-SCPU01

General Specifications

Safety Input Specifications

Safety Output Specifications

Test Output Specifications

Note: Total simultaneous ON current: 1.4 A

Standards

Note: For details on operating precautions and other information required to

use the product, be sure to read the following operation manual: 
DeviceNet Safety Network Controller Operation Manual (Z906)

DST1-

@

SL-1

General Specifications

Safety Input Specifications

Note: For details on operating precautions and other information required to

use the product, be sure to read the following operation manual: 
DeviceNet Safety DST1-series Safety I/O Terminals Operation Manual
(Z904)

Safety Output Specifications

Test Output Specifications

Safety Output Specifications for Realy Outputs

Standards

DeviceNet communications 
power supply voltage

11 to 25 VDC (supplied from communications 
connector)

Unit power supply voltage

20.4 to 26.4 VDC (24 VDC 15% +10%)

I/O power supply voltage

Consumption 
current

Communica-
tions power 
supply

24 VDC, 15 mA

Internal cir-
cuit power 
supply

24 VDC, 230 mA

Overvoltage category

II

Noise immunity

Conforms to IEC 61131-2

Vibration resistance

10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2

Shock resistance

150 m/s2: 11 ms

Mounting method

35-mm DIN Track

Ambient operating tempera-
ture

10 to 55°C

Ambient operating humidity 10% to 95% (with no condensation)

Ambient storage tempera-
ture

40 to 70°C

Degree of protection

IP20

Weight

460 g max.

Input type

Sinking inputs (PNP)

ON voltage

11 VDC min. between each input terminal and G1

OFF voltage

5 VDC min. between each input terminal and G1

OFF current

1 mA max.

Input current

4.5 mA

Output type

Sourcing outputs (PNP)

Rated output current

0.5 A max. per output

Residual voltage

1.2 V max. between each output terminal and V2

Leakage current

0.1 mA max.

Output type

Sourcing outputs (PNP)

Rated output current

0.7 A max. per output (See note.)

Residual voltage

1.2 V max. between each output terminal 
and V1

Leakage current

0.1 mA max.

Certifying body

Standards

TÜV Rheinland

EN954-1:1996, EN60204-1:1997, EN61000-6-2:2001, 
EN61000-6-4:2001, EN418:1992, IEC61508 part1-7/
12.98-05.00, IEC61131-2/02.03, NFPA 79-2002, ANSI 
RIA15.06-1999, ANSI B11.19-2003

UL

UL1998 (pending), NFPA79 (pending), UL508, CSA22.2 
No14, UL1604

DeviceNet communications 
power supply voltage

11 to 25 VDC (supplied from communications 
connector)

Unit power supply voltage

20.4 to 26.4 VDC (24 VDC 15% +10%)

I/O power supply voltage

Consumption 
current

Communica-
tions power 
supply

DST1-ID12SL-1/MD16SL-1: 100 mA
DST1-MRD08SL-1: 110 mA

Overvoltage category

II

Noise immunity

Conforms to IEC 61131-2

Vibration resistance

10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2

Shock resistance

DST1-ID12SL-1/MD16SL-1: 150 m/s² 11 ms
DST1-MRD08SL-1: 100 m/s² 11 ms

Mounting method

35-mm DIN Track

Ambient operating tempera-
ture

10 to 55°C

Ambient operating humidity

10% to 95% (with no condensation)
DST1-MRD08SL-1: 10% to 85% (with no con-
densation)

Ambient storage tempera-
ture

40 to 70°C

Degree of protection

IP20

Weight

DST1-ID12SL-1/MD16SL-1: 420 g
DST1-MRD08SL-1: 600 g

Input type

Sinking inputs (PNP)

ON voltage

11 VDC min. between each input terminal and G1

OFF voltage

5 VDC min. between each input terminal and G1

OFF current

1 mA max.

Input current

6 mA

Output type

Sourcing outputs (PNP)

Rated output current

0.5 A max. per output

Residual voltage

1.2 V max. between each output terminal and V2

Leakage current

0.1 mA max.

Output type

Sourcing outputs (PNP)

Rated output current

0.7 A max. per point

Residual voltage

1.2 V max. between each output terminal and V1

Leakage current

0.1 mA max.

Relays

G7SA-2A2B, EN 50205 Class A

Minimum applicable load

1 mA at 5 VDC

Rated load for a resistive 
load

240 VAC: 2 A, 30 VDC: 2 A

Rated load for an inductive 
load

2 A at 240 VAC (cos =0.3),
1 A at 24 VDC

Mechanical life expectancy

5,000,000 operations min. (switching frequency 
of 7,200 operations/h)

Electrical life expectancy

100,000 operations min. (at rated load and 
switching frequency of 1,800 operations/h)

Certifying body

Standards

TÜV Rheinland

EN954-1/12.96, EN60204-1/12.97, EN61000-6-2/10.01, 
EN61000-6-4/10.01,EN418/1992, IEC61508 part1-7/
12.98-05.00,IEC61131-2/02.03, NFPA 79-2002,ANSI 
RIA15.06-1999, ANSI B11.19-2003

UL

UL1998, NFPA79, UL508, CSA22.2 No14, UL1604 
(DST1-ID12SL-1 and DST1-MD16SL-1 only)

Summary of Contents for NE1A -

Page 1: ...s safety design Programmable safety circuits are incorporated to facilitate efficient designing and modifications Moreover Safety I O Terminals can be added to increase safety I O capacity for distributed allocation through the network DeviceNet wiring on the existing net work can be used as is facilitating efficient design by expanding on the existing system The programmability of safety circuits...

Page 2: ...ncorporates 16 safety inputs and 8 safety outputs Functions as a compact safety PLC even without using a network Construct safety circuits easily with special Function Blocks Up to 128 Function Blocks can be used DeviceNet Safety Communications Functions Provides DeviceNet Safety Master functionality Connect up to 16 Safety Slaves Expand using up to sixteen Input Slaves with 12 points each 192 poi...

Page 3: ...r USB Previous Safety Control Circuits Programmable Safety Circuits Emergency Stop Pushbutton Switch Safety Door Switch Safety Relay Unit Safety Network Controller Safety Relay Unit Safety Relay Unit Contactor Contactor Contactor Contactor Safety Network Configurator Safety logic operations can be programmed using Function Blocks Safety Door Switch NE1A SCPU01 Safety Network Controller Contactor E...

Page 4: ...tain Safety Light Curtain Safety Door Switch Previous Machine Connections Connecting Devices Using DeviceNet Safety Safety control DeviceNet Safety Safety Network Controller Safety Network Controller Contactor Contactor Contactor Contactor Contactor Emergency Stop Pushbutton Switch Contactor Safety I O Terminal Safety I O Terminal Safety I O Terminal Example of Safety I O Configuration for Distrib...

Page 5: ...Terminal Safety I O Terminal Network system settings and Safety Network Controller programming NS series Programmable Terminal Safety Network Controller with Safety interface Incorporating DeviceNet Slave functionality Monitor safety I O and status information from the DeviceNet Master directly without requiring a gateway or other interface System Configuration Example for Total Control of Machine...

Page 6: ...12 PNP Inputs 4 Test Outputs Removable Cage Clamp Terminals DST1 ID12SL 1 8 PNP Inputs 8 PNP Outputs 4 Test Outputs Removable Cage Clamp Terminals DST1 MD16SL 1 4 PNP Inputs 4 relay Outputs 4 x 2 single pole 4 Test Outputs Removable Cage Clamp Terminals DST1 MRD08SL 1 Appearance Appearance Description Part Number Installation Disk CD ROM IBM PC AT Compatible Windows 2000 or XP WS02 CFSC1 E English...

Page 7: ...1996 EN60204 1 1997 EN61000 6 2 2001 EN61000 6 4 2001 EN418 1992 IEC61508 part1 7 12 98 05 00 IEC61131 2 02 03 NFPA 79 2002 ANSI RIA15 06 1999 ANSI B11 19 2003 UL UL1998 pending NFPA79 pending UL508 CSA22 2 No14 UL1604 DeviceNet communications power supply voltage 11 to 25 VDC supplied from communications connector Unit power supply voltage 20 4 to 26 4 VDC 24 VDC 15 10 I O power supply voltage Co...

Page 8: ...nd monitoring from a standard PLC Standard I O communications Explicit message communications Safety control using Safety Network Controller Safety I O communications Compatible computer IBM PC AT or compatible CPU Pentium 300 MHz min OS Windows 2000 or XP Supported languages English Memory 128 Mbytes min Hard disk 40 Mbytes min available space Monitor Display functionality of S VGA monitor or hig...

Page 9: ...T3 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 29 30 Internal circuits G0 G0 T0 T1 T0 T1 T0 T1 T2 T3 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 11 12 13 14 15 16 17 18 19 20 31 32 33 34 35 36 37 38 39 40 V0 Physical layer Input power supply circuits Test output circuits Output power supply circuits Safety input circuits Safety output circuits DC DC converter non isolated V0 IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 V1 ...

Page 10: ...0 G2 M IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 Emergency Stop Switch and Reset Safety Outputs Safety Output and Output Feedback V G IN0 12 22 S2 11 E1 E1 E1 E2 DST1 ID12SL 1 V1 G1 DST1 MD16SL 1 E1 24 VDC Power Supply e g S8VS S1 Emergency stop pushbutton switch direct operation mechanism S2 Reset switch E1 24 VDC Power Supply e g S8VS L1 and L2 Loads 21 T0 IN1 T1 T2 G...

Page 11: ...NE1A SCPU01 90 4 99 111 1 24VDC 10 1 ON 1 0 1 0 3 2 5 4 7 6 1 0 3 2 5 4 7 6 1 0 3 2 5 4 7 6 9 8 11 10 13 12 15 14 3 2 5 4 7 6 9 8 11 10 13 12 15 14 SAFETY NETWORK CONTROLLER 0 0 USB NS MS LOCK COMM NE1A SCPU01 NODE ADR BAUD RATE V0 G0 24VDC OUT IN V1 G1 V1 G2 T0 T2 T1 T3 V1 G1 V1 G2 T0 T2 T1 T3 V0 G0 1 2 3 4 O N 114 1 131 4 ...

Page 12: ...he interest of product improvement specifications are subject to change without notice Cat No Z907 E2 01 X OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 568 13 00 Fax 31 23 568 13 88 www eu omron com ...

Reviews: