background image

Instruction manual

• English

• Deutsch

• Nederlands

U22

IM-NE-U22-E-04-08/2010

1665580-0C

NE-U22-E_C_en-de-nl_M11_100824.pdf

Summary of Contents for Micro A-I-R U22

Page 1: ...Instruction manual English Deutsch Nederlands U22 IM NE U22 E 04 08 2010 1665580 0C NE U22 E_C_en de nl_M11_100824 pdf...

Page 2: ...shown on the packaging or in this instruction manual They will be pleased to assist you OMRON HEALTHCARE EUROPE B V Intended use 3 Safety precautions 4 Features and benefits 5 Contents of the OMRON M...

Page 3: ...nscious or are not breathing spontaneously Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office in a room of general household and in open air...

Page 4: ...he main unit and AC adapter with water do not immerse them in water Do not drop medication on the main unit or on the AC adapter If you drop medication immediately wipe it off Do not apply strong shoc...

Page 5: ...just two penlite batteries your medication is always within reach wherever you go whatever you do Inhalation is possible at various angles The device enables inhalation at various angles with stable n...

Page 6: ...Unit Medication Container Mouthpiece Mask Adapter Mesh Cap with Mesh Instruction Manual Warranty Card Optional item not included contact your OMRON dealer AC Adapter Child Mask PVC Adult Mask PVC Sof...

Page 7: ...Stabilizes nebulisation 6 Medication Port Medication can be filled here by opening the mesh cap 7 Vibrator The tip of this vibrator oscillates at high frequency and pushes the medication through the p...

Page 8: ...ith the vibrator 13 Battery Low Indicator An orange light blinks when the batteries are low 14 ON OFF button 15 Electrodes Connects the vibrator with the main unit 16 Power indicator A green light tur...

Page 9: ...acity and condition of the batteries the unit can operate up to 8 days on a set of batteries based on usage of 30 minutes a day When the battery low indicator orange flashes the batteries should be re...

Page 10: ...nnector Press firmly until it clicks Plug in the power plug of the AC adapter to the electrical outlet To remove the AC adapter connector from the main unit remove the power plug from the electrical o...

Page 11: ...he medication container from the main unit To do so push on the release buttons on both sides This will disengage the latch mechanism Medication container release Buttons Lift up the Mesh Cap by placi...

Page 12: ...capacity is 7 ml 5 Install the mesh cap Do not touch the mesh The mesh cap seals the medication bottle Confirm if the cap is securely installed 6 Install the medication container on the main unit Clic...

Page 13: ...main unit 8 Install the mask or mouthpiece on the mask adapter The device is now ready for use Refer to the next section on how to select the nebulisation mode and how to inhale How to assemble the un...

Page 14: ...bulisation mode If you hold the ON OFF I button for approx 2 seconds or more the unit nebulises in the manual nebulisation mode The unit only nebulises while you keep on pressing the I button and stop...

Page 15: ...ach deep in to the bronchial tubes Hold your breath briefly then breathe out slowly while removing the mouthpiece from your mouth Do not breathe too quickly Pause when you feel like having a rest You...

Page 16: ...d mask 1 Remove the mask adapter from the main unit 2 Remove the medication container from the main unit 3 Remove the mesh cap from the medication container discard the medication and open the medicat...

Page 17: ...the mesh with a cotton swab or with a pin 6 Shake off excessive water from the parts and let them air dry on a clean lint free paper towel 7 Clean the main unit and it s electrodes by wiping it off w...

Page 18: ...nutes of boiling shake off excessive water from the parts and let them air dry on a clean lint free paper towel 2 Disinfection by using alcohol All parts can be disinfected by using alcohol Note Alcoh...

Page 19: ...lorhexidine Amphoteric surfactant Disinfecting ethanol Milton 0 1 Osvan 0 1 Hibitane 0 5 Tego 0 2 Mouthpiece SEBS Mask Adapter PC Medication Container Body PSF Horn Titanium Hinges Titanium Packing Si...

Page 20: ...ay clog the tiny holes in the mesh cap Leave the mesh cap in a white vinegar solution 1 part vinegar diluted with 3 parts of water for 1 hour In addition the mesh cap may be kept overnight in a cup of...

Page 21: ...mmercially available recharger The batteries are inserted in the wrong direction Re insert the batteries in the correct direction Refer to page 9 The AC adapter is not correctly connected to the main...

Page 22: ...ting Trouble Possible cause Corrective action The green power indicator turns on but the unit does not nebulise Medication or water has collected on the electrodes on the main unit Remove the medicati...

Page 23: ...tainer Mesh Cap Mask Adapter Mouthpiece 2 Batteries AA LR6 Child Mask PVC Adult Mask PVC Soft Pouch Instruction Manual Warranty Card Notes Subject to technical modification without prior notice This O...

Page 24: ...icle size distribution and aerosol output may vary by combination of product medication and ambient conditions such as temperature humidity and atmospheric pressure Performance may vary with drugs suc...

Page 25: ...lectromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601 1 2 2007 standard...

Page 26: ...types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local go...

Page 27: ...27 Optional parts and accessories Adult Mask PVC A040002 Child Mask PVC A040003 Main Unit Cover P040012 Mesh Cap P040014 AC Adapter 4125 0380 ADC A040004 Mask Adapter P040015 Mouthpiece P040016...

Page 28: ...are com Production facility OMRON MATSUSAKA Co Ltd 1855 370 Kubo cho Matsusaka city Mie prefecture 515 8503 JAPAN Subsidiary OMRON HEALTHCARE UK LIMITED Opal Drive Fox Milne Milton Keynes MK15 0DG U K...

Reviews: