background image

INSTRUCTION SHEET

Camera Mount Lighting Controller
for Photometric Stereo Lighting

Model

 

FL-TCC1PS

© OMRON Corporation  2017  All Rights Reserved. 

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

TRACEABILITY INFORMATION:

Importer in EU

Omron Europe B.V.

Wegalaan 67-69

2132 JD Hoofddorp,

The Netherlands

Manufacturer

Omron Corporation,

Shiokoji Horikawa, Shimogyo-ku,

Kyoto, 600-8530 JAPAN

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause

radio interference, in which case the user may be required to

take adequate measures to reduce interference.

PRECAUTIONS ON SAFETY

 Meanings of Signal Words

Indicates a potentially hazardous situation which, if 

not avoided, will result in minor or moderate injury, 

or may result in serious injury or death. Additionally, 

there may be significant property damage.

WARNING

Indicates a potentially hazardous situation which, if 

not avoided, may result in minor or moderate injury 

or in property damage.

CAUTION

 Meanings of Alert Symbols

Prohibition

Indicates general prohibitions.

LED Light Hazard

Indicates the possible danger of LED light.
High Temperature Caution

Indicates the possible danger of injury by high 

temperature under specific conditions.

 Alert Statements in This Sheet

This product is not designed or rated for ensuring safety 

of persons either directly or indirectly. Do not use it for 

such purposes.

WARNING

Looking into the LED light continuously may cause visual 

impairment. Do not look the LED light directly.

CAUTION

Minor burns may occasionally occur.

Do not touch the case while the LED is ON or immediately

after the power is turned OFF.

Please observe the following precautions for safe use of the products.

 

Installation Environment

∙ Do not use the product in areas where flammable or explosive 

gases are present.

∙ To secure the safety of operation and maintenance, keep an enough 

distance from high-voltage devices and power devices.

∙ The case of this product is connected to the 0 V line of the internal 

circuit. Do not ground the case main body to prevent from invasion 

of noise.

∙ Be sure to use the camera mounting plate provided with the main 

unit when installing the product.Make sure to tighten with the 

specified torque described in this Sheet when mounting the Camera 

mount plate.

 Power Supply and Wiring

∙ Connect only to the applicable image sensor controller (FH series), 

camera (FH-S series, FZ-S series), and light (FL-PS

W series). 

Use of other devices may result in fire, explosion, malfunction or 

failure.

∙ Make sure to use the product with the power supply voltage specified.

∙ Do not reverse the polarity of the power connection.

∙ Do not apply voltages or AC power supplies that exceed the rated 

voltage.

∙ Supply power from a DC power supply for which measures have 

been applied to prevent high voltages (e.g., a safety extra low 

voltage circuit).

∙ Be sure to remove the terminal block from of the main unit when 

wiring the product to the 24 V external input terminal block.

∙ To wire the terminal block, connect a applicable cord (AWG14-12) 

and the length of the power supply cable should be as short as 

possible (30 m max). However, when FL-PS260W is used  in the 

length of the power supply line at least 15m, adjust the power 

voltage to  become 24-26.4 V.

∙ Always turn OFF the power of the product before connecting or 

disconnecting a cable. 

∙ Secure the minimum bending radius of the cable for at least 20 mm. 

Otherwise the cable may be damaged.

∙ Do not apply exessive stress to the cables and connectors. It may 

damage the cables and connectors.

∙ Before turning on the power after the wiring is completed, verify 

that the power is correct, that there are no incorrect connections 

such as a shorted load circuit, and that the load current is suitable. 

Incorrect wiring may cause damage and failures.

 Others

∙ The main body may become extremely hot while the power is 

supplied or immediately after the power is turned OFF. Do not 

directly touch the main body.

∙ If you notice an abnormal condition such as a strange odor, extreme 

heating of the unit, or smoke, immediately stop using the product, 

turn off the power, and consult your dealer.

∙ Do not attempt to disassemble, deform by pressure, incinerate, 

repair, or modify this product.

∙ Do not drop or impose excessive vibration or shock on the product. 

It may cause breakdown of the product.

∙ When disposing of the product, treat it as an industrial waste.

 Applicable standards

 This lighting complied with the EN standard (EN61326-1)

 (Electromagnetic environment : Industrial electromagnetic 

environment (EN/IEC 61326-1 Table 2))

∙ Also, the following condition is applied to the immunity test of this 

product.

There are case that Lighting brightness fluctuate Max 10%.

Observe the following to prevent failure, malfunctioning, and adverse 

effects on performance and the device.

 Installation Sites

Install and store the product in a location that meets the following 

conditions:

∙ Place where the surrounding temperature is below or above 0 to 

40°C (-15 to 60°C in storage).

∙ Place where no rapid changes in temperature (place where dew 

condensation not form).

∙ Place where the relative humidity is below or above 35 to 85%.

∙ No presence of corrosive or flammable gases.

∙ Place free of dust, salts and iron particles.

∙ Place free of vibration and shock.

∙ Place out of direct sunlight.

∙ Place where it will not come into contact with water, 

oils or chemicals.

∙ Place not affected by strong electro-magnetic waves.

∙ Place not near to high-voltage, or high-power equipment.

PRECAUTIONS FOR SAFE USE

 Power Supply and Wiring

∙ Turn ON the power of this product and Image Sensor Controller at 

the same time or this product first.

∙ For cable extension, use an optional extension cable (FL-XC

PS).

 Maintenance

∙ Turn OFF the power and ensure the safety before maintenance. 

∙ Lightly wipe off dirt with a soft cloth.

∙ Never use paint thinner, benzene, acetone, or kerosene to clean the 

product.

 

Warming Up

∙ After turning on the power supply, allow the controller to stand for 

at least 30 minutes before use. As the circuits are unstable 

immediately after power ON, brightness may gradually change.

PRECAUTIONS FOR CORRECT USE

 

Relevant Manuals

Refer to other related manuals.

∙ Vision System FH/FZ5 Series Processing Item Function Reference 

Manual (Man.No. Z341)

No.

1

2

3

4

5

6

7

Name

Lighting connection cable

Camera connecting cable

24 V external power

supply input terminal block

Mounting hole for

fixing screw

POWER LED

RUN LED

ERROR LED

Description

Connects the LED lighting.

Connects to the extension connector

of the camera.

Connects the 24 VDC power supply.

Model: BLF5.08HC/02/180SNB

(Manufactured by Weidmuller)

Holes to mount screws to secure

the Lighting Controller to a mounting

plate or device.

Lights up green when the

24 V power is supplied.

Lights up green when preparation of

lighting is complete.

Lights up red when an error occurs.

 

Parts Names and Functions

 

Specifications

Model

Applicable Image

Sensor Controller

Applicable Cameras

Applicable lighting

Number of 

connected lightings

Power supply voltage (*)

Recommended

power supply

Current consumption 

Drive method

Luminance Control

Method

Trigger lighting

Lighting duration

setting

Lighting time

control

External interface

Ambient Temperature

Ambient Humidity

Degree of Protection

Vibration Resistance

Shock Resistance

Material

Weight

Accessories

FL-TCC1PS

FH series

FH-S series, FZ-S series

FL-PS series

1

24 VDC±10% (including ripple)

S8VK-G12024

(manufactured by OMRON, 24 VDC, 5 A 120 W)

3.0 A max.

Constant voltage method

Duty light adjustment: light adjustment of

255 levels 

(configured with image sensor controller)

Lighting in synchronization with trigger input

timing from the controller

(configured with image sensor controller).

Auto setting in accordance with

shutter speed.

Set with image sensor controller or set 

in accordance with shutter speed.

Camera connection cable (directly

connected with the main unit) 400 mm

Lighting connection cable (directly

connected with the main unit) 400 mm

Operating: 0 to 40°C  Storage: –15 to +60°C

(with no icing nor no condensation)

Operating and storage: 35% to 85%

(with no condensation)

IP20 (IEC60529)

10 to 150 Hz, (0.35mm double amplitude)

80 min. each in X, Y, and Z directions

150 m/s

2

 3 times each in 6 directions

(up/down, left/right, forward/backward)

Case: Alminum, Cable: PVC,

Camera Mount Plate: POM

Approx. 200 g

Instruction Sheet (this Sheet), 24 V power

supply terminal block (male),

Compliance Sheet, mounting screws

(M2 set screw x 4, M2 flat head screw x 4,

M4 flat head screw x 4)

* When FL-PS260W is used  in the length of the power supply line at 

least 15m, adjust the power voltage to  become 24-26.4 V.

 

Mounting the Controller to the Camera

The Lighting Controller can be mounted to the Camera using the 

provided Camera Mount plate. Mounting directions are: (1) 

Top/Bottom mount, (2) Right side mount, (3) Left side mount. As the 

location of the screw hole of the mounting plate used differs depending 

on the camera to be mounted, refer to the figure below for proper 

mounting. (The recommended mounting screw torque: M4 screw: 1.2 

Nm, M2 screw: 0.15 Nm)

< Step 1: Mount the Camera and  the Camera mount plate >

(1) Top/bottom mount

(2) Right side mount

(3) Left side mount

- Mounting to FH-SM/SC/SM02/SC02/SM04/SC04/

SMX05/SCX05/SMX12/SCX12/SM21R

/

SC21R

FZ-S5M3/SC5M3

(MOUNTING HOLE)

12-4.5 dia. through-hole

12-9.9 dia. flat-head 90 deg.

Use four M4 flat-head screws.

: Use for top/bottom mount

: Use for R side mount

: Use for L side mount

- Mounting to FH-SMX/SCX/SM05R/SC05R

FZ-S/SC

(MOUNTING HOLE)

9-2.5 dia. through-hole

9-4.9 dia. flat-head 90 deg.

Use three M2 flat-head screws.

: Use for top/bottom mount

: Use for R side mount

: Use for L side mount

- Mounting to FZ-S2M

SC2M

(MOUNTING HOLE)

9-2.5 dia. through-hole

9-4.9 dia. flat-head 90 deg.

Use three M2 flat-head screws.

: Use for top/bottom mount

: Use for R side mount

: Use for L side mount

- Mounting to FZ-S2M

SHC

(MOUNTING HOLE)

12-4.5 dia. through-hole

12-9.9 dia. flat-head 90 deg.

Use four M4 flat-head screws.

: Use for top/bottom mount

: Use for R side mount

: Use for L side mount

< Step 2: Mount the Lighting Controller and  the Camera mount plate >

Fix with four M2 set screws.

4-M2x0.4 (mounting screw hole)

< Step 3: Cable the Lighting Controller with the Camera  >

 

Mounting

Align the inner grooves of the connectors on the camera connection 

cable side and camera side with each other, and insert the cable until it 

clicks to lock it.

Before mounting

After mounting

Camera

Camera connection cable

 

Removal

Hold the connector on the camera connection cable side in the arrowed 

direction, and pull it out straight.

Before removal

After removal

Camera

Camera connection cable

[NOTE]

Do not grab the cable and pull it out with a unreasonable force to 

remove it. Doing so might cause breakage.

[IMPORTANT]

- Do not touch the internal terminals of the connector. Doing so might 

cause a failure.

- Avoid the cable and connector from being vibrated or shocked.

- Do not install the devices loading the connector constantly, for 

example, the cable is being tensed.

Terminal No.
1
2

(1)

(2)

Signal name
24 VDC(

)

24 VDC(

)

Description
24 V power supply input
0 V power supply input

< Step 4: Connect the lighting controller and the lighting >

 

Mounting

Align the grooves of [Lighting connection cable side connector of 

lighting controller] and [Lighting side connector] and rotate the plug 

part until it clicks.

Before mounting

After mounting

 

Removal

Rotate the plug part of [Lighting connection cable side connector of 

lighting controller] to remove it from [Lighting side connector].

Before removal

After removal

 

Cable extension

To extend the distance of the Lighting and the Lighting Controller, be 

sure to use the separately sold extension cable (FL-XC

PS).

[IMPORTANT]

- Avoid the cable and connector from being vibrated or shocked.

- Do not install the devices loading the connector constantly, for 

example, the cable is being tensed.

 

Connection with the 24V external

input terminal block

[IMPORTANT]

- To wire the terminal block, connect a applicable cord (AWG14-12) 

and the length of the power supply cable should be as short as 

possible (30 m max). However, when FL-PS260W is used  in the 

length of the power supply line at least 15m, adjust the power voltage 

to  become 24-26.4 V.

- Be sure to wire the power supply separately from other devices. 

Wiring the power supply together with other devices or wiring it to 

the same duct may result in erroneous operation or damage of the 

product due to interference by electromagnetic induction.

- Avoid the wire and terminal block from being vibrated or shocked. 

Do not install the devices loading the terminal block constantly, for 

example,  the wire being tensed.

 

Sequence to turn ON power

When supplying the power to the Lighting Controller (FL-TCC

PS), 

make sure to turn ON the power supply to the product first or at the 

same time with the Image Sensor Controller (FH). If you reverse this 

order, the input power to the product is not recognized so that ERROR 

LED will light up and lighting will not light. Turn ON the power of the 

Image Sensor Controller again.

FL-TCC1PS

Power input

ON

OFF

Image Sensor Controller 

power input

ON

OFF

 

If the power input is provided first to FL-TCC1PS

Recognizes the power supply input.

FL-TCC1PS

Power input

ON

OFF

Image Sensor Controller 

power input

ON

OFF

 

If the power input to FL-TCC1PS and the power input to 

the Image Sensor Controller are provided at the same 

time

Normally turns ON and the lighting turns ON.

FL-TCC1PS

Power input

ON

OFF

Image Sensor Controller 

power input

ON

OFF

 

Power supply input to Image Sensor Controller first

ERROR LED turns ON and therefore the lighting does not turn ON 

as the power input to FL-TCC1PS is not recognized. Turn ON the 

power of the Image Sensor Controller again.

(Unit: mm)

30

12.4

21.1

6.7

82

26

64.4

40

5

18.7

6.2

2-Ø3

96

4
4

12.5

2.4

40

89.6

(43)

50

400

(30)

400

50

(35)

Ø10.6

89.6±0.1

28

±

0.1

12.5

±

0.1

40

96

5

 

Dimensions

Lighting connector

Camera connection

connector

POWER SUPPLY

INPUT TERMINAL

BLOCK

LED indicator lamp

 

Camera mount plate (provided)

4-M2.6

(through hole)

4-M2

(through hole)

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 

codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 

limitations of use which apply to the Product. This information by itself is not 

sufficient for a complete determination of the suitability of the Product in 

combination with the end product, machine, system, or other application or 

use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

Oct, 2014

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.

Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Tightening torque (M2 screw): 0.15 N•m

Reviews: