12 to 24 VDC (Allowable voltage 
 fluctuation range: 10 to 30 VDC)
 (Class 2 Power Supply only)

K7L-AT50D

   0 

Ω

 to 50 M

Ω

, variable

   Range 0: 0 to 250 k

Ω

                

   Range 1: 0 to 600 k

Ω

 

   Range 2: 0 to 5 M

Ω

   Range 3: 0 to 50 M

Ω

Note: Set pins 1,2, or 3 of the DIP
           switch on the side of the Sensor

            Amplifier to the upwards position

        according to the range to be
           selected. These pins, which are
           arranged in numerical order from
           left to right, correspond to
           ranges 1 through 3. Be sure to
           set only the corresponding pin to
           the upward position. For range
           0, set all these switches
           downwards. The adjuster
           (ADJUST) on the front panel
           allows resistance changes from
           0 Ω to the upper limit of the set
           range. The adjuster is set to the
           upper limit as default. (Normally,
           the adjuster should be set to the
           upper limit).

K7L-UD

   0 

Ω to 1 M Ω , variable.

Note : 

The adjuster on the front panel

           allows resistance changes from

           0 Ω to the upper limit of the set

           range. The adjuster is set to the

           upper limit as default. (Normally,

           the adjuster should be set to the

           upper limit). 

Rated 

power

supply

voltage
Operation
resistance

Model

 

K7L-AT50D/AT50D-S

Model

 

K7L-UD(F03-20T) 

Liquid Leakage Sensor 
Amplifier

1227587-5 C

INSTRUCTION MANUAL

Thank you for purchasing this OMRON product. Read 
this instruction manual and thoroughly familiarize 
yourself with the functions and characteristics of the 
product before using it. Keep this instruction manual 
for future reference.

Safety Precautions

Indicates a potentially hazardous 
situation which, if not avoided, may 
result in minor or moderate injury or in 
property damage.

Do not touch the terminals.
Doing so may possibly result in electric 
shock.

Do not allow pieces of metal or wire 
clippings to enter the product while 
power is being supplied. Electrical shock, 
fire or malfunction may result.

 Definition of Precautionary Information

 Precautionary Information

CAUTION

CAUTION

 Specifications

K7L-AT50D     : Terminal Block, Terminator and 
                             scredriver are included.
K7L-AT50D-S : Terminal Block and screwdriver is 
                             included. Please order F03-20T, the
                             terminator, spearately.
K7L-UD            : Terminal Block, Terminator and 
                             screwdriver are included in a box.
F03-20T           : The terminator. Use together with 
                             K7L-AT50D.

Model description /Accessories

Precautions for Safe Use

1.Environmental Precautions

Use and preserve within the proper temperature 

and humidity described in the specifications.

Avoid preserving (including during 

transportation) and using in a humid place, in a 
corrosive gas environment, outdoors and in a 
place which receives direct sunlight.

   (To detect liquids with high impedances, do not 

use in locations with high humidity.)

Preserve and use without exposing to danger of 

explosion, flammable dust, gas and vapor, 
excessive dust, and saline spray or droplets.

Avoid preserving (including during 

transportation) and using in a place where 
vibration and shock are strong.

Do not store or use (including during 

transportations) where an influence of a static 
electricity or an electric field.

Do not install the product near devices 

generating strong high-frequency waves or 
surges. 

・To prevent inductive noise, separate Product 

as far as possible from high-voltage or 

high-current lines. Do not place Product wiring 

in parallel with or in the same path as 

high-voltage or high-current lines.

・Do not install near devices that generate heat, 

such as a coil or a device contains winding 

part, etc.

This is a class A product. In residential areas it

   may cause radio interference, in which case the
   user may be required to take adequate measures
   to reduce interference.

2.Usage Precautions

Read the instruction manual and catalog before 

operating and maintaining the product.

For items such as control power supply or power 

supply to provide input power, as well as 
distribution cable, use proper specified items.
[Recommended cable: three-core cabtire cable(s) 
of completely insulated 600V 0.75mm2 VCT]

Use the product within the rated load.

Check the usage, the wiring system and the 

power source of this product again before using it.

・Please wipe off the electrode area soaked in 

the liquid.

・Do not touch the terminals while power is 

being supplied. Not doing so may result in 

electric shock.

・Do not clean the Product with paint thinner or 

other organic solvents. Use commercial 

alcohol.

・Do no hold and pull the cable

 Sockets 

P2RF-08-E

16

4

85.5

max.

3.5-dia. hole

2

1.5

M3 screw

11.5

61 max.

35.5

39.5

3 dia.

2

48 max.

84 max.

Including height of DIN track

 Liquid Leakage Sensor Amplifier

 Connections

K7L-AT50D : Total 60m max. (NOTE. Sensing Band length : 10m max.)

K7L-UD       : Total 400m max.

23

4

42

3

5

6

7

8

4

3

2

1

K7L-AT50D/K7L-UD

(BOTTOM VIEW)

Liquid leakage 
detection output

BURN OUT

COM

 

Terminator

F03-20T

4-2

2-4

100 mA at 30 VDC maximum

Open collector output

OUT

Disconnection 
detection output

Common

Signal 

transmission
Level input 1

Level input 2

Commercial wiring cable 
(more than 0.2 mm

2

)

12 VDC to 24 VDC

Terminal Block 
for connection
F03-20

Liquid Sensing Band
F03-16PE

 Terminal Block

 Terminator Block

2

3

4

2

3

29.1

23.1

3

3

4

3.2

3.2 25

2

1

3

2

3

4

5

×

3=15

2.5

3.5

3.5

17.5

5.8

17

5.8

TYPE F03-20

23

±

0.2

2-M3

Mounting holes

3.2

3.2

25

TYPE F03-20T

18

±

0.2

2-M3

2-4

4-2

24.1

18.1

3

3

3.5

3.5

12.5

5.8

17

5.8

Mounting holes

The resistance value adjuster is a precision component. Do not apply a torque to the resistance value adjuster 

in excess of the specified one. Doing so may cause the resistance value adjuster to be damaged.

    Applicable torque:
        

 Rotational torque : 9.81 m N

m max.

        

 Detent strength    : 29.4 m N

m min.

For liquid leakage detection, use Sensing Band for Omron made.

   Omron Sensing Band : F03-15, F03-16PE, F03-16PT and F03-16SF.
    Please refer to Precautions described in a datasheet.

To wire correctly, please make sure terminal numbers.

Check the application and power supply.

Use DC power supply of "Class 2 Power Supply" as a condition of UL/CSA approval.

P r e c a u t i o n s   f o r   C o r r e c t   u s e

 Wiring

 Installation

 Adjuster

 Leakage Sensing Band

The terminator must be needed for disconnection detection of wiring cable or wiring cable or Sensing Band.

Be sure to connect the Sensing Band between K7L terminals 2 to 4, and the other end of Sensing Band must be 

connected to a terminator (no matter the polarity of the terminator) (See Block Diagram for External 
Connections below).

Refer to Terminal Block for the connection, mounting method or materials.

During disconnection detection, liquid leakage will not be detected. As well as, during liquid leakage 

detection, disconnection will not be detected.

Applicable torque :       M3 scerws : 0.49 N

m type.

 Terminator (F03-20T, 2P)

Use OMRON socket, P2RF-08/P2RF-08-E Surface  Socket.

Use the F03-20 Terminal Block included with the product.

   To make connections, insert the cable from the side of the Terminal Block with a screwdriver inserted in the 

top.

   After work has been completed, ensure that the devices are still electrically connected.
   The Terminal Block made with 66 nylon. Be sure to securely mount the Terminal Block with M3 scerws in a 

place where it will not come into contact with chemicals.

Applicable torque : M3 scerws : 0.49 N

m type.

This product has been designed to limit the influence of noise.

   However, in order to limit the influence of noise when the location to be monitored is far away, position the 

Sensor and the Sensing Band/Point Sensor as close together as power supply and outputs far away.

 Surface Socket

 Terminal Block

 Wiring Cable

Attach to a panel of thickness 1 to 5mm.

In case of DIN rail clamping, attach the slider to the product and fasten it to the slider with the projecting   

points of unit-side matched to the rail.

When removing the product from the rail, insert screwdriver into the groove of slider and slide it outward.

12.8

28.8

46

Operate, Release                : 800 ms max.

Disconnection detection : 10 s max.

Reset the power supply to stop 

disconnection detection.

Response

time

105 % min. of operae resistance

Release
resistance

NPN open-collector transistor for both 
liquid leakage detection an d 
disconnection detection output with    
100mA at 30 V DC max.

Note: For output ON when liquid

           leakage is detected: 

           Set pin 4 of the DIP swich

           located on the side of the

           Sensor Amplifier in the down

           position.

           For output OFF when liquid

           leakage is detected:

           Set pin 4 of the DIP swich

           located on the side of the

           Sensor Amplifier in the up 

           position.

K7L-AT50D

    Wiring cable : 50 m max.
    Sensing Band : 10 m max.

K7L-UD

    Overall cable length (wiring cable and 

Sensing Band length total) : 400 m max.

Note: These values are possible on 
            condition that a completely 
            insulated 3-conductor VCT cable
            with a thickness of 0.75 mm

2

            and dielectric strength of 600 V
            is used together with Liquid
            Sensing Band Type F03-16PE
            specified by OMRON. (A0.2-
            mm

2

 cable can also be used.)

Note: When using K7L by CE marking
            or Safety Category 1 approved,
            a power supply line is wired by
            less than 10m. 

Operation : -10 to +55 

Operation : 45 to 85%RH

Output
configuration

Ambient

temperature

Ambient

humidity

Wiring
distance

Terminal block (for connecting wiring
cable and Sensing Band/Point Sensor)
F03-20T Terminator 1
(End unit for disconnection detection)
Screwdriver for ADJUST setting.
(Purchases the Sensing Band, Sensing          
Band Sticker, Point Sensor, Wiring
cable, and Socket etc separately.)
The Terminal Block is 3P ; the Terminator 
is 2P.

Accessories

Frequency : 10 to 150 Hz; Acceleration : 

15m/s

2

, 10 sweeps of 8 min each in X, Y, 

and Z directions.

Vibration 
resistance

150 m/s

2

  3 times each in 3 axes, 6 

directions.

Shock 
resistance

Lit when power is being supplied :
  PW LED (Green) 
Lit when Liquid Leakage is detected : 
  OUT LED (Red)
The indicator flashes when disconnection 
detected : 
  OUT LED (Red)

Indicator

Omron Companies shall not be responsible for conformity with 
any standards, codes or regulations which apply to the 
combination of the Product in the Buyer’s application or use of 
the Product. At Buyer’s request, Omron will provide applicable 
third party certification documents identifying ratings and 
limitations of use which apply to the Product. This information by 
itself is not sufficient for a complete determination of the 
suitability of the Product in combination with the end product, 
machine, system, or other application or use. Buyer shall be solely 
responsible for determining appropriateness of the particular 
Product with respect to Buyer’s application, product or system. 
Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN 
DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE 
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Suitability for Use

OMRON ELECTRONICS LLC.

One Commerce Drive Schaumburg, IL 60173-5302 U.S.A
Phone: 1-847-843-7900    Fax: 1-847-843-7787

OMRON EUROPE B.V.

Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands
Phone: 31-23-56-81-300    Fax: 31-23-56-81-388

OMRON ASIA-PACIFIC PTE. LTD.

No.438A Alexandra Road #05-05/08(Lobby 2), Alexandra
Technopark, Singapore 119967
Phone: 65-6835-3011   Fax: 65-6835-2711

OMRON CORPORATION

3-4-10 Toranomon Minato-ku, Tokyo, 105-0001 Japan
Phone: 81-3-3436-7260    Fax: 81-3-3436-7261

Contact Information

Reviews: