Functions and Oper
ations
5.23 Holding Maximum and Minimum Values
5-65
5.23 Holding Maximum and Minimum Values
• Each time the
[MAX/MIN] Key is pressed in the RUN level, the
maximum or minimum value recorded while a measurement is
being performed will be displayed.
●
Switching Maximum and Minimum Value Displays
Each time the
[MAX/MIN] Key is pressed in the RUN level, the PV display switches as follows: present
value
→
maximum value
→
minimum value
→
present value.
●
Resetting the Maximum and Minimum Values
The maximum and minimum values can be reset by a RESET input or
by pressing the
[MAX/MIN] Key for 1 s.
R P
C
Initializing
Measuring
Max. value
Min. value
Measurement status
Power supply
Initializing
Measuring
Measurement value
Measuring
Measurement stopped
90000
Max
1234
.
5
90000
3012
.
6
90000
985
.
7
Min
MIN value
MAX value
Present value
CMW
Hold
CMW
Hold
CMW
Hold
Summary of Contents for K35-2
Page 2: ......
Page 24: ...Outline Section 1 Outline 1 8 ...
Page 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Page 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Page 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Page 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Page 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Page 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Page 185: ......