Omron JX-AB002 System Configuration Manual Download Page 10

10

Frequency inverters

Line filters 

A

 Input AC Reactors

A

 DC Reactors

A

 Chokes

A

 Output AC Reactors

B

 Accessories

D

 Computer software

Inverter

Line filter Rasmi

Voltage

Model JX-

@

Reference

Rated current (A)

Weight (kg)

1-Phase 200 VAC

AB002 / AB004

AX-FIJ1006-RE

6

0.5

AB007

AX-FIJ1010-RE

10

0.6

AB015 / AB022

AX-FIJ1026-RE

26

0.8

3

-Phase 200 VAC

A2002 / A2004 / A2007

AX-FIJ2006-RE

6

1.0

A2015 / A2022 / A20

3

7

AX-FIJ2020-RE

20

1.

3

A2055 / A2075

AX-FIJ2040-RE

40

2.

3

3

-Phase 400 VAC

A4004 / A4007 /A4015 

AX-FIJ

3

005-RE

5

0.9

A4022 /A4040

AX-FIJ

3

011-RE

11

1.1

A4055 / A4075

AX-FIJ

3

020-RE

20

1.7

Inverter

AC Reactor

Voltage

Model JX-

@

Reference

3

-Phase 200 VAC

A2002 / A2004 / A2007 

AX-RAI02800080-DE

A2015 / A2022 / A20

3

7

AX-RAI00880175-DE

A2055 / A2075

AX-RAI00

3

50

33

5-DE

1-Phase 200 VAC

AB002 / AB004

Under development

AB007

AB015 / AB022

3

-Phase 400 VAC

A4004 / A4007 / A4015 

AX-RAI07700042-DE

A4022 / A4040

AX-RAI0

3

500090-DE

A4055 / A4075

AX-RAI01

3

00170-DE

200V single phase

200V 3-phase

400V 3-phase

Inverter

DC Reactor

Inverter

DC Reactor

Inverter

DC Reactor

JX-AB002

AX-RC107000

3

2-DE

JX-A2002

AX-RC21400016-DE

-

JX-AB004

AX-RC06750061-DE

JX-A2004

AX-RC107000

3

2-DE

JX-A4004

AX-RC4

3

000020-DE

JX-AB007

AX-RC0

3

51009

3

-DE

JX-A2007

AX-RC06750061-DE

JX-A4007

AX-RC270000

3

0-DE

JX-AB015

AX-RC025101

3

8-DE

JX-A2015

AX-RC0

3

51009

3

-DE

JX-A4015

AX-RC14000047-DE

JX-AB022

AX-RC0160022

3

-DE

JX-A2022

AX-RC025101

3

8-DE

JX-A4022

AX-RC10100069-DE

-

JX-A20

3

7

AX-RC0160022

3

-DE

JX-A4040

AX-RC06400116-DE

JX-A2055

AX-RC01110

3

09-DE

JX-A4055

AX-RC04410167-DE

JX-A2075

AX-RC008404

3

7-DE

JX-A4075

AX-RC0

33

50219-DE

Model

Diameter

Description

AX-FER2102-RE

21

For 2.2 KW motors or below

AX-FER2515-RE

25

For 7.5 KW motors or below

Inverter

AC Reactor

Voltage

Model JX-

@

Reference

200 VAC

A2001 / A2002 / A2004

 AB001 / AB002 / AB004

AX-RAO11500026-DE

A2007/AB007

AX-RAO07600042-DE

A2015 / AB015

AX-RAO04100075-DE

A2022 / AB022

AX-RAO0

3

000105-DE

A20

3

7

AX-RAO018

3

0160-DE

A2055

AX-RAO01150220-DE

A2075

AX-RAO00950

3

20-DE

400 VAC

A4004 / A4007 / A4015 

AX-RAO16

3

000

3

8-DE

A4022

AX-RAO1180005

3

-DE

A4040

AX-RAO07

3

00080-DE

A4055

AX-RAO04600110-DE

A4075

AX-RAO0

3

600160-DE

Types

Model

Description

Functions

Digital

oper

ato

r

AX-OP05-E

LCD remote 

operator

5 Line LCD remote operator 

with copy function, 

cable length max. 

3

m.

*

1

*

1

Please note, for JX inverters models, the operator will only display 2 lines of 
text.

3

G

3

AX-CAJOP

3

00-EE

Remote operator 

cable

3

 meters cable for connecting 

remote operator

3

G

3

AX-OP01

LED remote 

operator

LED remote operator, cable 

length max. 

3

m

4X-KITMINI

Mounting kit for 

LED operator

 Mounting kit for LED operator 

on panel

A

c

ce

ss

ori

e

s

3

G

3

AX-PCACN2

USB converter / 

USB cable

RJ45 to USB connection 

cable

3

G

3

AX-CTB020-EE

RJ45 T-Branch 

cable

T cable for RS-422 

connection

3

G

3

AX-CTR150-EE

RJ45 Terminator 

resistor

Terminator resistor for 

RS-422 connection

Types

Model

Description

Installation

S

o

ftwa

re

CX-drive

Computer 

software

Configuration and monitoring 

software tool

CX-One

Computer 

software

Configuration and monitoring 

software tool

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.0

3

9

3

7. To convert grams into ounces, multiply by 0.0

3

527.

Cat. No. I110E-EN-01C

Summary of Contents for JX-AB002

Page 1: ...tion PTC thermistor input Cooling fan switch control PC configuration tool CX Drive CE UL cUL RoHS Ratings 200 V Class single phase 0 2 to 2 2 kW 200 V Class three phase 0 2 to 7 5 kW 400 V Class three phase 0 4 to 7 5 kW System configuration Choke LCD 5 lines remote operator Remote operator extension cable Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models Output reactor RJ45 U...

Page 2: ...leration At capacitor feedback Approx 50 50 for 3 phase 20 to 40 for 1 phase Approx 20 to 40 Approx 20 Cooling method Self cooling Forced air cooling Three phase JX A4004 A4007 A4015 A4022 A4040 A4055 A4075 Motor kW 1 1 Based on a standard 3 Phase standard motor Applicable motor capacity 0 4 0 75 1 5 2 2 4 0 5 5 7 5 Output characteristics Inverter capacity kVA 380 V 0 9 1 6 2 5 3 6 5 6 8 5 10 5 48...

Page 3: ...acteristic selection upper lower limit 16 step speeds starting frequency adjustment jogging operation carrier frequency adjustment PID control frequency jump analog gain bias adjustment S shape acceleration deceleration electronic thermal characteristics level adjustment retry function simplified torque boost trip monitor soft lock function frequency conversion display USP function 2nd control fun...

Page 4: ...9 157 5 6 55 2 2 2 2 A2022 2 2 4 3 7 A2037 2 5 5 A2055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A2075 2 Three phase 400 V 0 4 A4004 2 98 176 110 189 130 5 2 6 28 1 5 0 75 A4007 2 157 5 6 55 2 3 1 5 A4015 2 2 4 2 2 A4022 2 4 0 A4040 2 5 5 A4055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A4075 2 Figure 1 Figure 2 6 5 5 W H1 W1 H t1 D1 1 9 D H1 5 H W1 W 5 6 t1 D1 D 1 9 Rasmi model Dimensions Weight kg ...

Page 5: ... 7 5 2 1 22 AX RC27000030 DE 105 1 60 AX RC14000047 DE AX RC10100069 DE 116 1 95 AX RC06400116 DE 108 135 133 120 82 6 5 9 5 9 5 3 70 AX RC04410167 DE 120 152 136 135 94 7 5 20 AX RC03350219 DE 146 6 00 Voltage Reference Dimensions Weight kg A B2 C2 D E F 200 V AX RAO11500026 DE 120 70 120 80 52 5 5 1 78 AX RAO07600042 DE 120 70 120 80 52 5 5 1 78 AX RAO04100075 DE 120 80 120 80 62 5 5 2 35 AX RAO...

Page 6: ...it bar Remove the short circuit bar between 1 and P 2 when a DC reactor is connected P N Regenerative braking unit connection terminal Connect optional regenerative braking units If a braking torque is required Grounding For grounding grounding should conform to the local grounding code Inverter R L1 S L2 T N L3 PCS P24 U T1 V T2 W T3 Motor Note To connect the DC reactor remove the short circuit b...

Page 7: ...n Input selection 5 Factory setting Multi step speed reference 1 L Multi function Input selection common Analog input signal H Frequency reference power supply 10 VDC 10 mA max O Voltage frequency reference signal 0 to 10 VDC 10 KΩ OI Current frequency reference signal 4 to 20 mA 250 Ω L Frequency reference common Digital output signals AL2 NC output Factory default relay settings Under normal ope...

Page 8: ... 0 1 5 AX RC03510093 DE 9 3 3 51 1 5 AX RC14000047 DE 4 7 14 0 2 2 AX RC02510138 DE 13 8 2 51 2 2 AX RC10100069 DE 6 9 10 1 3 7 AX RC01600223 DE 22 3 1 60 4 0 AX RC06400116 DE 11 6 6 40 5 5 AX RC01110309 DE 30 9 1 11 5 5 AX RC04410167 DE 16 7 4 41 7 5 AX RC00840437 DE 43 7 0 84 7 5 AX RC03350219 DE 21 9 3 35 200 V class 400 V class Max applicable motor output kW Reference Current value A Inductanc...

Page 9: ... E 1 5 7 1 JX A2015 E 2 2 10 JX A2022 E 3 7 15 9 JX A2037 E 5 5 24 JX A2055 E 7 5 32 JX A2075 E Three phase 400 V 0 4 1 5 JX A4004 EF 0 75 2 5 JX A4007 EF 1 5 3 8 JX A4015 EF 2 2 5 5 JX A4022 EF 4 0 8 6 JX A4040 EF 5 5 13 JXA4055 EF 7 5 16 JXA4075 EF Choke A B B LCD 5 lines remote operator Remote operator extension cable A A C C C C A Output reactor B D A USB cable CX Drive CX One MCCB JX Filter A...

Page 10: ...0840437 DE JX A4075 AX RC03350219 DE Model Diameter Description AX FER2102 RE 21 For 2 2 KW motors or below AX FER2515 RE 25 For 7 5 KW motors or below Inverter AC Reactor Voltage Model JX Reference 200 VAC A2001 A2002 A2004 AB001 AB002 AB004 AX RAO11500026 DE A2007 AB007 AX RAO07600042 DE A2015 AB015 AX RAO04100075 DE A2022 AB022 AX RAO03000105 DE A2037 AX RAO01830160 DE A2055 AX RAO01150220 DE A...