JX

JX

Compact & Complete

• V/f controlled inverter
• Side by side mounting
• Built-in EMC filter
• Built-in RS-485 Modbus
• Overload detection function (150% during 60s)
• PID
• Micro-surge voltage suppression
• Automatic energy saving
• Emergency shut-off
• Second motor setting
• Auto carrier-frequency reduction
• PTC thermistor input
• Cooling fan switch control
• PC configuration tool: CX-Drive
• CE, UL, cUL, RoHS

Ratings

• 200 V Class single-phase 0.2 to 2.2 kW
• 200 V Class three-phase 0.2 to 7.5 kW
• 400 V Class three-phase 0.4 to 7.5 kW 

 

System configuration

Choke

LCD 5 line

s

 remote

oper

a

tor

Remote oper

a

tor 

exten

s

ion c

ab

le

* Only needed for 3 ph

as

e 200 V or to comply C1 on 3 ph

as

e 400 V model

s

O

u

tp

u

t re

a

ctor

RJ45 - U

S

B c

ab

le

CX-Drive 
CX-One

*

MCCB

JX

Filter

AC re

a

ctor

Motor

Gro

u

nd

Power 

su

pply

DC re

a

ctor

Summary of Contents for JX-AB002

Page 1: ...tion PTC thermistor input Cooling fan switch control PC configuration tool CX Drive CE UL cUL RoHS Ratings 200 V Class single phase 0 2 to 2 2 kW 200 V Class three phase 0 2 to 7 5 kW 400 V Class three phase 0 4 to 7 5 kW System configuration Choke LCD 5 lines remote operator Remote operator extension cable Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models Output reactor RJ45 U...

Page 2: ...leration At capacitor feedback Approx 50 50 for 3 phase 20 to 40 for 1 phase Approx 20 to 40 Approx 20 Cooling method Self cooling Forced air cooling Three phase JX A4004 A4007 A4015 A4022 A4040 A4055 A4075 Motor kW 1 1 Based on a standard 3 Phase standard motor Applicable motor capacity 0 4 0 75 1 5 2 2 4 0 5 5 7 5 Output characteristics Inverter capacity kVA 380 V 0 9 1 6 2 5 3 6 5 6 8 5 10 5 48...

Page 3: ...acteristic selection upper lower limit 16 step speeds starting frequency adjustment jogging operation carrier frequency adjustment PID control frequency jump analog gain bias adjustment S shape acceleration deceleration electronic thermal characteristics level adjustment retry function simplified torque boost trip monitor soft lock function frequency conversion display USP function 2nd control fun...

Page 4: ...9 157 5 6 55 2 2 2 2 A2022 2 2 4 3 7 A2037 2 5 5 A2055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A2075 2 Three phase 400 V 0 4 A4004 2 98 176 110 189 130 5 2 6 28 1 5 0 75 A4007 2 157 5 6 55 2 3 1 5 A4015 2 2 4 2 2 A4022 2 4 0 A4040 2 5 5 A4055 2 164 235 180 250 167 5 1 6 77 5 4 2 7 5 A4075 2 Figure 1 Figure 2 6 5 5 W H1 W1 H t1 D1 1 9 D H1 5 H W1 W 5 6 t1 D1 D 1 9 Rasmi model Dimensions Weight kg ...

Page 5: ... 7 5 2 1 22 AX RC27000030 DE 105 1 60 AX RC14000047 DE AX RC10100069 DE 116 1 95 AX RC06400116 DE 108 135 133 120 82 6 5 9 5 9 5 3 70 AX RC04410167 DE 120 152 136 135 94 7 5 20 AX RC03350219 DE 146 6 00 Voltage Reference Dimensions Weight kg A B2 C2 D E F 200 V AX RAO11500026 DE 120 70 120 80 52 5 5 1 78 AX RAO07600042 DE 120 70 120 80 52 5 5 1 78 AX RAO04100075 DE 120 80 120 80 62 5 5 2 35 AX RAO...

Page 6: ...it bar Remove the short circuit bar between 1 and P 2 when a DC reactor is connected P N Regenerative braking unit connection terminal Connect optional regenerative braking units If a braking torque is required Grounding For grounding grounding should conform to the local grounding code Inverter R L1 S L2 T N L3 PCS P24 U T1 V T2 W T3 Motor Note To connect the DC reactor remove the short circuit b...

Page 7: ...n Input selection 5 Factory setting Multi step speed reference 1 L Multi function Input selection common Analog input signal H Frequency reference power supply 10 VDC 10 mA max O Voltage frequency reference signal 0 to 10 VDC 10 KΩ OI Current frequency reference signal 4 to 20 mA 250 Ω L Frequency reference common Digital output signals AL2 NC output Factory default relay settings Under normal ope...

Page 8: ... 0 1 5 AX RC03510093 DE 9 3 3 51 1 5 AX RC14000047 DE 4 7 14 0 2 2 AX RC02510138 DE 13 8 2 51 2 2 AX RC10100069 DE 6 9 10 1 3 7 AX RC01600223 DE 22 3 1 60 4 0 AX RC06400116 DE 11 6 6 40 5 5 AX RC01110309 DE 30 9 1 11 5 5 AX RC04410167 DE 16 7 4 41 7 5 AX RC00840437 DE 43 7 0 84 7 5 AX RC03350219 DE 21 9 3 35 200 V class 400 V class Max applicable motor output kW Reference Current value A Inductanc...

Page 9: ... E 1 5 7 1 JX A2015 E 2 2 10 JX A2022 E 3 7 15 9 JX A2037 E 5 5 24 JX A2055 E 7 5 32 JX A2075 E Three phase 400 V 0 4 1 5 JX A4004 EF 0 75 2 5 JX A4007 EF 1 5 3 8 JX A4015 EF 2 2 5 5 JX A4022 EF 4 0 8 6 JX A4040 EF 5 5 13 JXA4055 EF 7 5 16 JXA4075 EF Choke A B B LCD 5 lines remote operator Remote operator extension cable A A C C C C A Output reactor B D A USB cable CX Drive CX One MCCB JX Filter A...

Page 10: ...0840437 DE JX A4075 AX RC03350219 DE Model Diameter Description AX FER2102 RE 21 For 2 2 KW motors or below AX FER2515 RE 25 For 7 5 KW motors or below Inverter AC Reactor Voltage Model JX Reference 200 VAC A2001 A2002 A2004 AB001 AB002 AB004 AX RAO11500026 DE A2007 AB007 AX RAO07600042 DE A2015 AB015 AX RAO04100075 DE A2022 AB022 AX RAO03000105 DE A2037 AX RAO01830160 DE A2055 AX RAO01150220 DE A...

Reviews: