background image

5.1  Limits for connecting and disconnecting the SJDE-**APA-OY

9

5  Restrictions for Use.

Some restrictions for the use of the JUSP-JC001 commnunication board are described below. The 
communication board should always be used within these specifications.

5.1 Limits for connecting and disconnecting the SJDE-**APA-OY

The connnector on the SJDE-**APA-OY servopack is not specified to be frequently  connected and 
disconnected to the communication cable. The number of times is restricted to 20 times. It is there-
fore recommended to only use the communication board for startup and maintenance.

5.2. Bending specification for the cable attached to JUSP-JC001

There is no bending specification for the communication cable. Therefore it is possible that the 
cable may be damaged due to frequent bending.

5.3 Range of Usage

Due to the restrictions for the connection between JUSP-JC001 and SJDE-**APA-OY the commu-
nication board should only be used  in the following cases:

• Machine setup (setting of the gear ratio)

• Maintenance (Checking by using the monitor function)

Please do not run the machine with the JUSP-JC001 connected to the SJDE-**APA-OY servopack.

5.4 Connection restriction

Digital Operator and Personal Computer may not be connected to the JUSP-JC001 at the same 
time.

5.5  Other Comments

•Please make a sure connection between the JUSP-JC001 and the SJDE-**APA-OY oth-
erwise contacting problems may occur.

•There is a possibility that the cover for JUSP-JC001 on the SJDE-**APA-OY will be dam-
aged due to frequent bending. So please use this cover with care.

•The connector for the JUSP-JC001 is keyed and can only be inserted in one position, if 
the connector is inserted wrong with force the connector pins can break. To prevent wrong 
insertion the color of the wire for pin 1 is red.

Summary of Contents for JUNMA Series

Page 1: ...OMRONYASKAWAMotionControlB V JUNMA SERIES SERVO DRIVE Document No 900 019 243 01 OY JUSP JC001 Communication Board for SJDE APA OY User Manual...

Page 2: ...liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is con stantly striving to improve its high quality products the information contained in this...

Page 3: ...of the additional functions for the JUNMA series AC SERVOPACKs Related Manuals Refer to the following manuals as required Manual Name Manual Number JUNMA series User Manual TOEP C71080601 01OY JUNMA...

Page 4: ...1 Connector specification 6 3 1 2 Connector Pin Arrangement 6 3 2 CN9 Connection Cable for Personal Computer 6 3 2 1 Connector specification 6 3 2 2 Connector Pin Arrangement 7 3 3 CN52 Connector for...

Page 5: ...2...

Page 6: ...mputer with JunmaWin software Model Number JUSP JC001 Connectors CN3 Connector for digital operator The connector CN3 is the same as Sigma V CN9 Connector for Personal computer with JunmaWin software...

Page 7: ...environment and installation is as follows 2 2 Dimension 2 2 1 Dimensions of the communication board Dimensions are 50 W x 30 H x 75 D mm see Fig 2 below Items Specification Ambient temperature 0 50...

Page 8: ...2 2 Dimension 5 2 2 2 Layout and Dimensions of the JUSP JC001 connection cable See figure 3 below 75 50 CN3 CN 52 CN9 Fig2 Dimension of Unit...

Page 9: ...C14LFDTN SLE PLUS 14P Cable Side Maker Honda Model Number Connector HDR E14MAG1 14P Model Number Connector Case HDR E14LPA5 Pin Number Symbol I O Function 1 TXD O Transmitting 2 TXD O Transmitting 3 R...

Page 10: ...in arrangement Pin Number Symbol I O Function 1 TXD I Transmitting 2 RXD O Receiving 3 RXD GND GND 4 RXD GND GND Board Side Maker JST Model Number S8B ZR SM4A TF LF SN Cable Side Maker JST Model Numbe...

Page 11: ...8 4 Block Diagram The block diagram is shown in the figure below CN52 CN9 CN3 RS422 D R RS232C D R SJDE APA 8 pole Junm aW in PC 4 pole Digital Operator 14 pole TXD TXD TXD RXD RXD RXD TXD0 RXD0 5V VC...

Page 12: ...nding 5 3 Range of Usage Due to the restrictions for the connection between JUSP JC001 and SJDE APA OY the commu nication board should only be used in the following cases Machine setup setting of the...

Page 13: ...6 Repair Product repair is not planned if the product is defective please exchange the product 5 7 Related Documents Supplement for additional functions for SJDE APA OY and SJDE ANA OY Document number...

Page 14: ...8 www omron industrial com Austria Tel 43 0 1 80 19 00 www omron at Belgium Tel 32 0 2 466 24 80 www omron be Czech Republic Tel 420 234 602 602 www omron cz Denmark Tel 45 43 44 00 11 www omron dk Fi...

Reviews: