background image

Automatic Wrist

Blood Pressure Monitor

 !"#$%&'

Model

 

 

IW2

INSTRUCTION MANUAL

===

En_TC-Cover[IW2]-1

2/16/05, 11:18 AM

Page 1

Adobe PageMaker 6.5C/PPC

Summary of Contents for IntelliSense IW2

Page 1: ...Automatic Wrist Blood Pressure Monitor Model IW2 INSTRUCTION MANUAL ...

Page 2: ...d Pressure 5 Initial Set Up 6 Battery Installation Replacement 6 How to Set the Date and Time 8 Correct Usage 10 How to Apply the Wrist Cuff 10 How to Take a Reading 11 How to Use the Memory Function 14 How to Modify the Settings 16 Troubleshooting 18 Care and Maintenance 20 Specifications 21 ...

Page 3: ...e three most recent measurements The OMRON Wrist Monitor uses the oscillometric method of blood pressure measurement This means the monitor detects the pulse wave vibrations in the artery of your wrist and converts the oscillations into a digital reading Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm Changes in wrist blood press...

Page 4: ...r Do not use the unit on infants or persons who cannot express their consent Do not use the unit for any purpose other than measuring blood pressure Do not use a cellular phone or other devices that emit electromagnetic fields near the unit This may result in incorrect operation of the unit Battery liquid may leak and damage the main unit Please observe the following points When you are not going ...

Page 5: ...nitor is at the correct position Memory Value Symbol Displayed when viewing values stored in memory Average Value Display Displayed when viewing the average value for last three measurements Cuff Deflation Symbol Pulse Display Diastolic Blood Pressure Date Time Display Battery Low Symbol Irregular Heartbeat Symbol Right Wrist Measurement Symbol Position Sensor Alarm Symbol Systolic Blood Pressure ...

Page 6: ...our right hand on the cuff itself 2 Press the START STOP button Remain quiet sit still and do not talk during the measurement Notes Always wait at least 2 3 minutes before taking another blood pressure measurement You may require more rest time between readings depending on your individual physiological characteristics Only use the IW2 to measure your own blood pressure since the results of measur...

Page 7: ...he polarities of the battery compartment as indicated 3 Replace the battery cover Note Make sure that the battery cover is securely in position Caution Use two identical 1 5V AAA batteries Note The measurement values continue to be stored in memory even after the batteries are replaced 6 Battery Installation Replacement M E M S E T S T A R T S T O P M E M S E T S T A R T S T O P M E M S E T S T A ...

Page 8: ...tteries provided are for monitoring and may run down before 300 readings If the battery low symbol blinks while measuring or if pressure is not applied when the START STOP button is pressed replace both batteries use the same type Holding the START STOP button down may shorten battery life To avoid pressure on the button when transporting or storing use the case provided Dispose of batteries accor...

Page 9: ...e installed for the first time the year digits 2004 will flash on the display when you turn on the monitor Note The range for the year setting is 2004 to 2030 If the year reaches 2030 it will return to 2004 If you need to reset the date and time press the SET button until the setting you want to adjust appears on the display then press the MEM button to change the setting 2 Press the MEM button to...

Page 10: ... to set the month and date day 5 Repeat steps 2 and 3 to set the hour and minutes for the time Note The monitor will automatically turn itself off after you press the SET button to confirm the minute setting 9 How to Set the Date and Time ...

Page 11: ...ling so that it fits comfortably Make sure that the wrist cuff does not cover the protruding part of the wrist bone ulna on the outside of the wrist Unless the wrist cuff is wrapped securely around the wrist it may not be possible to take correct measurements 4 The remaining part of the wrist cuff can be conveniently folded back out of the way Taking measurements on the right wrist Measurements ca...

Page 12: ...your arm is in the correct position the wrist cuff will automatically start to inflate and measurement starts Notes If your wrist is too low or too high the position sensor alarm will emit a series of two short bleeps similar to a heartbeat Sit still and do not talk or move until the measurement is completed Keep the monitor at heart height until the measurement is completed To stop measurement pr...

Page 13: ...on automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol If the irregular heartbeats cause the measurement to be invalid no result is shown If the irregular heartbeat symbol is shown after you have taken a measurement repea...

Page 14: ...e heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination Whether the appearance of the irregular heartbeat symbol in the results indicates arrhythmia o...

Page 15: ...the measurement results are recorded correctly make sure that the date and time are set correctly before taking a measurement When 90 sets of readings are stored in memory the oldest set will be deleted to store a new set The date and time of stored readings will be alternately displayed To View the Average Value Press the MEM button To View Previous Readings Stored in Memory 1 Press the MEM butto...

Page 16: ...e earliest stored in memory 4 Press the SET button repeatedly to cycle through the readings To Delete All Values in Memory You cannot delete the stored readings partially all readings in the monitor will be deleted To delete stored readings press the MEM button and the START STOP button simultaneously all readings will be deleted 15 How to Use the Memory Function ...

Page 17: ...ymbol appears on the display 2 Press the MEM button to select on or oFF When on is selected the monitor displays symbols to indicate how close your wrist is to the correct measuring position Setting the Position Sensor Alarm 1 Press the SET button until the Position Sensor Alarm Symbol appears on the display The default settings is on1 and this emits a series of two short blips if your wrist is to...

Page 18: ...elect on1 on2 or oFF Turning Right Wrist Measurement On Off 1 Press the SET button until the right wrist measurement symbol appears on the display Select on to measure your blood pressure using your right wrist 2 Press the MEM button to select on or oFF 17 ...

Page 19: ... Measure while in the correct posture Is the cuff wrapped snugly around the wrist Wrap the cuff correctly Are your arms and shoulders tense Relax and try taking the measurement again Have you been talking or moving your hands during measurement Keep still and do not talk during measurement The blood pressure is different each time The reading is extremely low or high Blood pressure readings consta...

Page 20: ...ad and repeat the steps listed under How to Apply the Wrist Cuff An E mark is displayed Contact the store where you purchased this unit or the nearest OMRON dealer After several seconds After several seconds The battery power is low Replace the batteries with two new AAA batteries Wrist is not in the correct position Carefully read and repeat the steps in How to Take a Reading Make sure that the s...

Page 21: ...o extreme temperatures humidity or direct sunlight Washing the cuff or exposing the cuff or monitor to water Disassembling the monitor Subjecting the monitor to strong shocks or vibrations Do not drop the monitor Cleaning the monitor with volatile liquids The MONITOR SHOULD BE CLEANED WITH A SOFT DRY CLOTH 20 ...

Page 22: ...er Supply Two AAA batteries LR03 Battery Life Approximately 300 measurements when using alkaline batteries at room temperature of 23 C three times a day and inflating to 170 mmHg Operating Temperature and Humidity 10 C to 40 C 30 to 85 RH Storage Temperature and Humidity 20 C to 60 C 10 to 95 RH Weight of Main Unit Approximately 110 g not including batteries External Dimensions 70 mm w x 54 mm h x...