Omron INTELLI 637IT Instruction Manual Download Page 4

7

English

6

Systolic Blood 

Pressure Display

Diastolic Blood 

Pressure Display

Date/Time Display

Pulse Display

button 

Push 

to move the displayed item

forward. Push 

to move the dis-

played item backward. 

Mark 

Displayed when a stored

measurement is shown.

SETTING button

Push this button to set

various items on the moni-

tor such as time and date.

GRAPH CALL

button

Push this button to

see the graph.

MEMORY

RECALL button

Push this button to

see the measured

values stored in

the monitor.

ON/OFF button

Push this button to

measure your

blood pressure or

to switch the moni-

tor off.

How to Insert the Batteries

Use this monitor after inserting batteries in the main unit.

1.

Open the battery compartment

.

2.

Insert the batteries (Type LR03 / AAA) as shown in the figure.

Ensure the polarity (+/-) of the batteries is correct.

3.

Close the battery cover.

Please disconnect your 637IT from your PC when you replace the batteries.

With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal
conditions. Please switch of the monitor after using it. If you forget to switch the monitor off it will
switch off itself after app. 2 minutes. Please take the batteries out of the monitor if you intend not to
use the monitor for a long period (app. 2 months).

How to Set the Date and Time

Before using your OMRON 637IT for the first time, you have to

set the date and time. After turning the monitor on by pushing the

O/I button the initial screen (see picture) will be available for a

few seconds. After the initial screen you will proceed automatical-

ly to the TIME SET screen. (For instruction how to set the date

and time refer also to page 16 in Chapter How to change the set-

tings.)

After reaching the time screen you will see the Gregorian calen-

dar (year day/month). The year will be flashing. 

1. By using the (       ) buttons you can set the current year. 

2. By pushing the SET button you will lock the year and proceed 

to the next item.

For setting the month, date and time repeat step 1 and 2. After

setting the minutes you will proceed to the DELETE DATA

screen. Please turn off your monitor by pushing the O/I button.

Your OMRON 637IT is ready for use now.

Initial Screen

Time Screen

How to Measure Blood Pressure Correctly

How to wrap the cuff

In order to measure your blood pressure correctly it is needed to wrap the cuff around your wrist in a
correct way. If not, correct measurements are not possible. Please follow the coming instructions (left
wrist):

1) Make sure that your wrist is bare and will be wrapped over your skin.
2) Make sure that you clothing is not constraining the flow of your blood.
3) Make sure that the wrist (left or right) to measure is selected from the settings menu (see also

page 15). The left wrist is preset.

Summary of Contents for INTELLI 637IT

Page 1: ...dig automatische bloeddrukmeter voor de pols Manuel d instructions 637IT Tensiomètre entièrement automatique pour prise de mesure au poignet Manual de instrucciones 637IT Aparato completamente automático para medir la presión arterial en la muñeca Manuale di instruzioni 637IT Misuratore della pressione per il polso completamente automatico English Deutsch Nederlands Français Italiano Español 637IT...

Page 2: ...ing signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk of damage to you and others The icons and meanings are shown as follows Warning sign Contents Indicates matters in which bodily harm or material damage may arise as a result of incorrect handling Caution The icon indicates prohibitions what you cannot do Matters invol...

Page 3: ...measure their own blood pressure in consultation with their doctor since the readings may be changed by the pregnancy Please remember Self measurement is not the same as medical treatment You should never change the dose of medicines as prescribed by your doctor Before using your OMRON 637IT for the first time Your blood pressure monitor the benefits The OMRON 637IT is a compact fully automatic wr...

Page 4: ... How to Set the Date and Time Before using your OMRON 637IT for the first time you have to set the date and time After turning the monitor on by pushing the O I button the initial screen see picture will be available for a few seconds After the initial screen you will proceed automatical ly to the TIME SET screen For instruction how to set the date and time refer also to page 16 in Chapter How to ...

Page 5: ...sture Achieving a correct posture before measuring your blood pressure is important since an incorrect posture might give you incorrect readings To achieve a correct posture please follow the instructions see pictures 1 Sit down and stretch your back 2 Relax yourself by relieving the stress from your shoulders and arms 3 Breath several times deeply and return to natural respiration 4 Do not sustai...

Page 6: ...asurement is finishes the deflation mark flashed and the cuff deflates How to enlarge the reading The results will be shown on your display By pushing the buttons you can enlarge the readings How to Use the Memory Function Date and Time of Measurement Your OMRON 637IT blood pressure monitor is able to store maxi mum 90 measurements including date and time When your blood pressure monitor is holdin...

Page 7: ...n of Data in Flashing Display Display screen where the systolic blood pressure values higher than 170 mmHg are measured twice Graph Display Screen of Hypertension Type The systolic blood pressure is higher than 170mmHg When a systolic blood pressure above 170 mmHg is measured twice the symbol is displayed in the graph When a systolic blood pressure above 170 mmHg is measured three times the sym bo...

Page 8: ...itched ON or OFF In the factory preset the position sensor is enabled If the position sensor is switched ON you can choose to have the optimal wrist height supported by an acoustic sound SIGNAL ON or OFF Measuring Wrist Screen Measuring Wrist Right Wrist Screen Left or right wrist measurement Normally blood pressure is measured on the left wrist factory preset With your OMRON 637IT you can choose ...

Page 9: ...rmation by selecting YES all the settings will be changed to the factory mode The monitor will return to the AUTO MEMORY SCREEN You can turn off your monitor by pushing the O I button How to use the computer interface This blood pressure monitor has a computer interface and is supplied with software to transfer the memory of the blood pressure monitor to your personal computer Required operating e...

Page 10: ...ble to transfer the memory of your 637IT blood pressure monitor to your personal computer By pressing the TIME button you are able to set the date and time in your 637IT blood pressure monitor By pressing the ID button you are able to set your personal name in your 637IT blood pressure monitor By pressing the CLOSE button you are closing the program How to set the time Press the TIME button on you...

Page 11: ...ressure Optimal blood pressure target value Normal blood pressure Normal systolic value Mild hypertension Moderate hypertension Severe hypertension Hypertension guide The World Health Organization WHO and the International Society of Hypertension ISH estab lished the Blood Pressure Classification Use this Classification as the guide to know the state of your blood pressure However if you are conce...

Page 12: ...spirits thinners or similar solvents Stains on the cuff can be carefully removed using a moist cloth and soapy water Do not wash the cuff or make it wet Please make sure no water will enter the main unit Keep your monitor in the storage case protected from extreme temperatures and humidity Do not carry out repairs of any kind yourself If a defect occurs consult your OMRON dealer or dis tributor Pl...

Page 13: ...the above mentioned measures please contact the nearest OMRON dealer or distributor Spare parts and accessories OMRON considers due to the used high company and quality standards the main unit as a non serviceable part because of the necessity of proper calibration after replacement of high tech components The cuff can be replaced by an authorised expert Specifications Name OMRON Fully Automatic B...