background image

7. Maintenance

7.1  Maintenance

To protect your scale from damage, follow the directions below:

•  Use a soft dry cloth, or a soft cloth moistened with mild (neutral) detergent to clean the 

scale.

•  Use a soft cloth moistened with rubbing alcohol to clean the plate.

•  Store the scale in a clean, safe location.

•  Do not use any abrasive or volatile cleaners, gasoline, thinners or similar solvents to 

clean the scale.

•  Do not clean the scale by immersing it in water.

7.2  Proper storage

The scale recalibrates automatically when it is not in use.

If the automatic calibration does not work, see section 8 for instructions on how to 

manually calibrate your scale.

To help ensure automatic calibration, do not store your scale as shown in images below:

The scale is leaning 

against the wall or 

other objects

The scale is placed 

upside down

The scale is placed 

on the carpet or 

mat

The object is 

placed on the 

scale

8. Calibration

To calibrate your scale, follow the instructions below.

1. Place the scale on a hard, flat and level floor.

2. Press the surface of the scale with your hand to turn on the power.

3. When “0.0 kg” is displayed, wait for 1 minute to turn the scale off.

Then you can take a measurement.

9. Specifications

Product name

OMRON Digital Weight Scale HN-300T2

Model

HN-300T2

Display

5 to 150 kg with an increment of 0.1 kg

Weight accuracy

5 kg to 150 kg : ±(1%+0.1 kg)

Transmission method

Bluetooth

®

 Low Energy

Wireless 

communication

Frequency range: 2.4 GHz (2400 - 2483.5 MHz)

Modulation: GFSK

Effective radiated power: <20 dBm

Power supply

4 “AAA” batteries

Battery life

Approximately 3 months: using manganese batteries

Approximately 6 months: using alkaline batteries
(When each types of batteries are used in two measurement, 

two data transfer a day at a room temperature of 23 °C)

Operating conditions

+5 to +40 °C, 30 to 85 % RH (non-condensing), 860 to 1060 hPa

Storage conditions

-20 to +60 °C, 10 to 95 % RH (non-condensing)

Weight

Approximately 1.5 kg 

including batteries

External dimensions

Approximately 290 (W) × 25.4 (H) × 270 (D) mm 

Contents

Digital weight scale, 4 “AAA” manganese batteries, 

instruction manual, 

start up guide

Notes:

•  These specifications are subject to change without notice.

•  Product production date is printed on the device: the first 4 digits mean year of 

production, the next 2 digits - month of production, the next 2 digits mean date of 

production.

About a wireless communication interference

This product operates in an unlicensed ISM band at 2.4 GHz. In the event this 

product is used near other wireless devices such as microwave and wireless LAN, 

which operate on the same frequency band as this product, there is a possibility that 

interference may occur. If interference occurs, stop the operation of the other devices 

or relocate this product away from other wireless devices before attempting to use it.

10. Guidance and Manufacturer’s Declaration

•  Hereby, OMRON HEALTHCARE Co., Ltd., declares that the radio equipment type 

HN-300T2 is in compliance with Directive 2014/53/EU.

•  This OMRON product is produced under the strict quality system of OMRON 

HEALTHCARE Co., Ltd., Japan. 

Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

This marking shown on the product or its literature, indicates that it should 
not be disposed of, with other household wastes at the end of its working 
life. To prevent possible harm to the environment or human health from 
uncontrolled waste disposal, please separate this product from other types 
of wastes and recycle it responsibly to promote the sustainable reuse of 
material resources.
Household users should contact either the retailer where they purchased 
this product, or their local government office, for details of where and how 
they can return this item for environmentally safe recycling. 
Business users should contact their supplier and check the terms and 
conditions of the purchase contract. This product should not be mixed with 
other commercial waste for disposal.

The 

Bluetooth

®

 word mark and logos are registered trademarks owned by the Bluetooth 

SIG, Inc. and any use of such marks by OMRON HEALTHCARE Co., Ltd. is under 

license. Other trademarks and trade names are those of their respective owners.

Apple and the Apple logo, are trademarks of Apple Inc., registered in the U.S. and other 

countries and regions. App Store is service mark of Apple Inc.

Google Play and the Google Play logo are trademarks of Google LLC.

Other trademarks and trade names are those of their respective owners.

Manufacturer

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, KYOTO,

617-0002 JAPAN

EU-representative

OMRON HEALTHCARE EUROPE B.V.

Scorpius 33, 2132 LR Hoofddorp,

THE NETHERLANDS

www.omron-healthcare.com

Importer in EU

Asia Pacific HQ

OMRON HEALTHCARE SINGAPORE PTE LTD.

438A Alexandra Road, #05-05/08, Alexandra Technopark

Singapore 119967

www.omronhealthcare-ap.com

Production facility

KRELL PRECISION (YANGZHOU) CO., LTD.

No. 28, Xingyang Road

Economic Development Zone

Yangzhou, Jiangsu 225009, China

Made in China