Thank you for purchasing the OMRON Upper Arm Blood Pressure Monitor.
Your new upper arm blood pressure monitor uses the oscillometric method of 
blood pressure measurement. This means the monitor detects your blood 
movement through your brachial artery and converts the movements into a 
digital reading. An oscillometric monitor does not need a stethoscope so the 
monitor is simple to use.

Intended Use

This device is a digital monitor intended for use in measuring blood pressure and 
pulse rate in adult patient population. The device detects the appearance of 
irregular heartbeats during measurement and gives a warning signal with 
readings. It is mainly designed for general household use. 

Important Safety Information

Please read the Important Safety Information in this instruction manual 
before using the unit.

Please follow this instruction manual thoroughly for your safety.
Please keep for future reference. For specific information about your own blood 
pressure, CONSULT YOUR DOCTOR.

Warning

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

• DO NOT adjust medication based on measurement results from this blood 

pressure monitor. Take medication as prescribed by your doctor. Only a doctor 
is qualified to diagnose and treat high blood pressure.

• DO NOT use this monitor on an injured arm or an arm under medical 

treatment.

• DO NOT wear the arm cuff on your arm while on an intravenous drip or blood 

transfusion.

• DO NOT apply or inflate the arm cuff around any body parts other than your 

upper arm.

• DO NOT use this monitor in areas containing high frequency (HF) surgical 

equipment, magnetic resonance imaging (MRI) equipment, computerized 
tomography (CT) scanners or in oxygen rich environments.

• DO NOT use this monitor on infants, toddlers, children or persons who cannot 

express themselves.

• Consult your doctor before using this monitor if you have common arrhythmias 

such as atrial or ventricular premature beats or atrial fibrillation; arterial 
sclerosis; poor perfusion; diabetes; pregnancy; pre-eclampsia; or renal 
disease.

• Always consult your doctor. Self-diagnosis of measurement results and 

self-treatment are dangerous.

• Contains small parts that may cause a choking hazard if swallowed by children, 

toddlers or infants.

• Keep the BATTERY out of the reach of children, toddlers and infants.
• This product emits radio frequencies (RF) in the 2.4 GHz band. DO NOT use 

this product in locations where RF is restricted, such as on an aircraft or in 
hospitals. 

Caution

Indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury to the 

user or patient or damage to the equipment or other 

property.

• Stop using this monitor and consult your doctor if you experience skin irritation 

or discomfort.

• Consult your doctor before using this monitor on an arm with an arterio-venous 

(A-V) shunt.

• Note that PATIENT motion, trembling, shivering may affect the measurement 

reading.

• Consult your doctor before using this monitor if you have had a mastectomy.
• Consult your doctor before using the monitor if you have severe blood flow 

problems or blood disorders as cuff inflation can cause bruising.

• Do not take measurements more often than necessary because bruising, due 

to blood flow interference, may occur.

• Remove the arm cuff if it does not start deflating during the measurement.
• Do not use this monitor for any purpose other than measuring blood pressure.
• Do not use a mobile phone or other electrical devices that emit electromagnetic 

fields near this monitor except when transferring your readings to your smart 
device. This may result in incorrect operation of this monitor.

• Do not disassemble or attempt to repair the monitor or components. This may 

cause an inaccurate reading.

• Do not use in a location where there is moisture or a risk of water splashing the 

monitor. This may damage the monitor.

• Do not use this monitor in a moving vehicle such as in a car or on an airplane.
• Do not drop, or subject this monitor to strong shocks or vibrations.
• Do not use this monitor in places with high or low humidity or high or low 

temperatures. See the “6. Specifications” section of the manual.

• Please check, by observation of the arm being used, that the monitor is not 

causing any impairment of patient blood circulation.

• Do not use this monitor in high-use environments such as medical clinics or 

doctor offices.

• Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 

30 minutes before taking a measurement.

• Rest for at least 5 minutes before taking the measurement.
• Remove tight-fitting or thick clothing from your arm while taking a 

measurement.

• Remain still and do not talk while taking a measurement.
• Read and follow the “Important information regarding Electro Magnetic 

Compatibility (EMC)” in the EMC information provided with this device.

• Read and follow the “Correct Disposal of This Product” in “6. Specifications” 

when disposing of the device and any used accessories or optional parts.

Data Transmission

• Do not replace the battery while your reading is being transferred to your smart 

device. This may result in the incorrect operation of your monitor and failure to 
transfer your blood pressure data.

• Do not place integrated circuit cards, magnets, metal objects, or other devices 

that emit electromagnetic fields near this monitor while your reading is being 
transferred to your smart device. This may result in the incorrect operation of 
your monitor and failure to transfer your blood pressure data.

Battery Handling and Usage

• Do not insert the batteries with their polarities incorrectly aligned.
• Use only 4 “AAA” alkaline batteries with this monitor. Do not use other types of 

batteries. Do not use new and used batteries together.

• Remove the batteries if the monitor will not be used for a long period of time.
• If battery fluid should get in your eyes, immediately rinse with plenty of clean 

water. Consult a doctor immediately.

• If battery fluid should get on your skin, wash your skin immediately with plenty 

of clean, lukewarm water. If irritation, injury or pain persists, consult a doctor.

• Do not use batteries after their expiration date.
• Periodically check your batteries to ensure they are in good working condition.
• Only use batteries specified for this monitor. Use of unsupported batteries may 

damage and/or may be hazardous to the monitor.

1. Know Your Device

Contents:

Monitor, battery set, instruction manual, setup instructions

Monitor:

1.1 Display symbols

Irregular Heartbeat Symbol ( )

When the monitor detects an irregular rhythm 
two or more times during the measurement, the 
irregular heartbeat symbol will appear on the 
display with the measurement values. 

An irregular heartbeat rhythm is defined as a 

rhythm that is 25% less or 25% more than the 
average rhythm detected while the monitor is 
measuring the systolic and diastolic blood 
pressure. 
If the irregular heartbeat symbol displays with your measurement results, 
we recommend you consult your doctor. Follow the directions of your 
doctor.

Movement Error Symbol ( )

The movement error symbol is displayed if you move your body during the 
measurement. Please remove the arm cuff, and wait 2 - 3 minutes. 
Take another measurement and remain still during measurement.

Cuff Wrap Guide Symbol (  /  )

If the cuff was wrapped too loosely, it may cause unreliable results. If the 
wrapping of cuff is too loose, the cuff wrap guide symbol “

” appears. 

Otherwise “

” appears. This is the function which is used as an aid in 

determining if the cuff is wrapped snugly enough. 

SYNC Symbol ( )

• When the SYNC symbol appears on the display, make sure that your 

monitor has been pairing with the smart device or transfer the data.

• When the SYNC symbol appears on the display, transfer the data before 

the measurements are deleted. If the memory is full, the monitor will be 
delete the oldest value. Maximum internal memory is for 100 
measurements.

2013 ESH/ESC Guidelines for the management of arterial hypertension

Definitions of hypertension by office and home blood pressure levels

These are from statistical values for blood pressure.

1.2 Before Taking a Measurement

To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and 

eating for 30 minutes before taking a measurement. 

2. Rest for at least 5 minutes before taking the measurement.
3. Stress raises blood pressure. Avoid taking measurements during 

stressful times.

4. Measurements should be taken in a quiet place.
5. Remove tight-fitting clothing from your arm.
6. Keep a record of your blood pressure and pulse readings for your 

doctor. A single measurement does not provide an accurate indication 
of your true blood pressure. You need to take and record several 
readings over a period of time. Try to measure your blood pressure at 
the same time each day for consistency.

2. Preparation

2.1 Battery Installation

1.

Remove the battery cover.

Gently slip into the gap of the 
hook and pull downward.

2.

Insert 4 “AAA” batteries as 
indicated, into the battery 

compartment.

3.

Replace the battery cover.

When the batteries have been securely placed in this device, the message 
and SYNC symbol below will appear on the screen:

Notes:
• When the depleted battery symbol “

” appears on the display, turn the 

monitor off and remove all the batteries. Replace with 4 new batteries at 
the same time. Long life alkaline batteries are recommended.

• The measurement values continue to be stored in the memory even after 

the batteries are replaced.

• The supplied batteries may have a shorter life than new batteries.
• Disposal of used batteries should be carried out in accordance with the 

national/local regulations for the disposal of batteries.

2.2 Pairing Your Monitor with a Smart Device

The date and time on your monitor will automatically be set when you pair 
it with your smart device.
To begin using the “OMRON connect” app for the first time, please visit 
omronconnect.com/setup for the initial set-up instructions.

1.

Turn on the 

Bluetooth

 feature of the smart device.

2.

Download and install the free “OMRON connect” app on 
your smart device.

* If you already have the “OMRON connect” app, go to:

Menu > Devices > Add Device

3.

Open the app on your smart device and follow the set-up 
and pairing instructions.

4.

Confirm the monitor is connected successfully.

If the monitor is connected successfully to the smart device, “OK” will 
appear on the display.

If “Err” appears, refer to “Connection failure. / Data is not being 
transmitted.” in section 4.2 for more detail.

Notes: 
• Pairing this monitor with the “OMRON connect” app on your smart device 

will set the date and time on this monitor. Once you have paired with the 
“OMRON connect” app, the date and time is now setup on this monitor, 
all future measurements will include the date and time when you transfer.  
If you do not pair this monitor to set the date and time, any

measurements you take with this monitor will not include the date and 
time.

• If you use an app other than the "OMRON connect" app, the date and 

time may not be set automatically on your blood pressure monitor.

• Please be aware that OMRON will not be responsible for the loss of data 

and/or information.

• If you use the monitor without pairing, refer to the “Using your Monitor 

without Pairing” in the “3.3 Taking a Measurement”.

3. Using the Device

3.1 Applying the Arm Cuff

Remove tight-fitting clothing from your left upper arm. 
Do not place the arm cuff over thick clothes.

1.

Apply the arm cuff to your left upper 

arm.

The bottom edge of the arm cuff should be 1 
to 2 cm above the elbow. Positioning the 
display in clear view of the user makes it 
easier to read the results.

2.

Securely close with the fabric 
fastener.

Notes:
• The blood pressure can differ between 

the right arm and the left arm, and the 
measured blood pressure values can be 
different. Omron recommends to always 
use the same arm for measurement. If 
the values between both arms differ substantially, please check with your 
doctor as to which arm to use for your measurements.

• Positioning the monitor with the [START/STOP] button towards the body 

makes it easier to use the device.

3.2 How to Sit Correctly

To take a measurement, you need to be relaxed and 
comfortably seated, at a comfortable room 
temperature. 

• Sit in a chair with your legs uncrossed and your feet flat on 

the floor.

• Sit upright with your back straight.
• Sit with your back and arm being supported.
• The arm cuff should be placed on your arm at the same level as your heart.

3.3 Taking a Measurement

Notes:
• To stop the measurement, press the [START/STOP] button once to 

deflate the arm cuff.

• Remain still and do not talk while taking a measurement.
• This device will store 100 measurements in the device. Stored 

measurements cannot be viewed on the monitor's display. You will need 
to use the “OMRON connect” app to view all measurements prior to the 
most recent reading taken.

• Do not use the monitor with other electrical device simultaneously. This 

may result in incorrect operation of the monitor.

1.

Press the [START/STOP] button.

The arm cuff will start to inflate.

 : The arm cuff was wrapped snugly enough.
 : The arm cuff was loose or not wrapped correctly.

Note: The cuff wrap guide result appears on the display during the 

measurement.

The following symbols indicate incorrect measurement

• If any of these symbols below are displayed, please take another 

measurement.

2.

Remove the arm cuff.

3.

Transfer your readings.

Please make sure your monitor is within 5 m (16 ft.) of your smart device 
and your “OMRON connect” app is active.

As soon as the measurement is complete, your reading will be 

automatically transferred to the app.

Transferring

 your readings later

1. Open the app on your smart device and then follow the instructions.
2. Press connection button to transfer your readings.

• If your readings are successfully transferred to your smart device, 

“OK” will flash on the display.

If “Err” appears, refer to “Connection failure. / Data is not being 
transmitted.” in section 4.2 for more detail.

Notes:
• When the SYNC symbol “

” appears on the display, transfer the data 

immediately before the readings are deleted.

• When the Connection OFF symbol “

” appears on the display, turn on 

the 

Bluetooth

 feature of your monitor. (Refer to section 3.4)

• Once you send the your readings to the app, the data cannot be resent to 

app or smart device.

4.

After your readings have been transferred to the “OMRON 

connect” app, press the [START/STOP] button to turn off.

Notes:
• The monitor will automatically turn off after 2 minutes.
• Wait 2-3 minutes before taking another measurement. Waiting between 

measurements allows the arteries to return to their prior condition to 
taking the measurement.

• If you use any other app instead of “OMRON connect”, the data may not 

be displayed correctly after sending.

Data Transfer With Multiple Smart Devices

Once you transfer your data to a smart device, that data cannot be 
transferred again to the same smart device, nor to another smart device.

About Multiple Users 

This monitor is recommended for personal use. 
When this monitor is used by more than one person, the measurement data 
will be combined. 

Using your Monitor without Pairing

You can use this blood pressure monitor without pairing to a smart device.
1. Apply the arm cuff. (Refer to section 3.1)
2. Press [START/STOP] button. (Refer to step 1 to 2 in section 3.3)
3. Write down your SYS/DIA and Pulse readings, along with the date and time 

of your measurement on a piece of paper to keep a record of your history.

Note: When using this blood pressure monitor without a smart device, you 

will not be able to view your prior readings stored in the memory.

Upper Arm 

Blood Pressure Monitor

Model HEM-7600T

Instruction Manual

Connection symbol

Battery symbol (low)

Connection OFF symbol

Battery symbol (depleted)

Connection ON symbol

Deflation symbol

Movement error symbol

Heartbeat symbol
(Flashes during measurement.)

SYNC symbol

Cuff Wrap Guide Symbol

Irregular heartbeat symbol

Office

Home

Systolic Blood Pressure

140 mmHg

135 mmHg

Diastolic Blood Pressure

90 mmHg

85 mmHg

A

B

C

D

E

A. START/STOP button

B. Connection button
C. Display
D. Arm cuff
E. Battery compartment

F. Systolic blood pressure
G. Diastolic blood pressure
H. Pulse display

G

H

F

Display:

Irregular Heartbeat

Normal Heartbeat

Pulse

Blood pressure

Blood pressure

Short Long

Pulse

 : Make sure to press the connection button to pair with the smart 

device or transfer the data before taking a measurement when 
the SYNC symbol 

“ ”

 appears.

Review the list of compatible smart devices at: 
omronconnect.com/devices
For details, visit: omronconnect.com

1 - 2 cm

START

INFLATING

DEFLATING

COMPLETED

Example:

DO NOT adjust medication based on measurement results from this blood 

pressure monitor. Take medication as prescribed by your doctor. Only a 
doctor is qualified to diagnose and treat high blood pressure.

Always consult your doctor. Self-diagnosis of measurement results and 

self-treatment are dangerous.

3125186-3A

HEM-7600T-AP3_A_M03_170119.fm  1 

  

Summary of Contents for HEM-7600T

Page 1: ...otion trembling shivering may affect the measurement reading Consult your doctor before using this monitor if you have had a mastectomy Consult your doctor before using the monitor if you have severe blood flow problems or blood disorders as cuff inflation can cause bruising Do not take measurements more often than necessary because bruising due to blood flow interference may occur Remove the arm ...

Page 2: ...he data When the SYNC symbol appears on the display transfer the data before the measurements are deleted If the memory is full the monitor will be delete the oldest value Maximum internal memory is for 100 measurements 2013 ESH ESC Guidelines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels These are from statistical values for blood...

Page 3: ...smart device will set the date and time on this monitor Once you have paired with the OMRON connect app the date and time is now setup on this monitor all future measurements will include the date and time when you transfer If you do not pair this monitor to set the date and time anyࠉ measurements you take with this monitor will not include the date and time If you use an app other than the OMRON ...

Page 4: ...being transmitted in section 4 2 for more detail Notes When the SYNC symbol appears on the display transfer the data immediately before the readings are deleted When the Connection OFF symbol appears on the display turn on the Bluetooth feature of your monitor Refer to section 3 4 Once you send the your readings to the app the data cannot be resent to app or smart device 4 After your readings have...

Page 5: ...settings of this monitor will not delete the information in the app When using this monitor again please delete the registration of the monitor in the app first and then pair your monitor 4 Error Messages and Troubleshooting 4 1 Error Messages Error Display Cause Solution Irregular heartbeat is detected Remove the arm cuff Wait 2 3 minutes and then take another measurement Repeat the steps in sect...

Page 6: ...d pressure monitor within 5 m 16 ft of the smart device and try again The Bluetooth feature of the smart device is turned off Turn on the Bluetooth feature of the smart device and your monitor and try sending the data again The Bluetooth feature of the blood pressure monitor is turned off Refer to To turn ON the Bluetooth in 3 4 Turning OFF the Bluetooth The blood pressure monitor did not pair suc...

Page 7: ...he medical electrical area that include RF transmitters or that intentionally apply RF electromagnetic energy for diagnosis or treatment Temperature limitation Humidity limitation Atmospheric pressure limitation Artery mark About a wireless communication interference This Product operates in the unlicensed ISM band at 2 4GHz In case this Product is used around the other wireless devices including ...

Page 8: ...es the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse Why is it a Good Thing to measure Blood Pressure at Home Many factors such as physical activity anxiety or the time of day can influence your blood pressure A single measurement may not be sufficient for an accurate diagnosis Thus it is best to try and measure yo...

Reviews: