Precautions

Power Supplies

When turning the power ON and OFF, input signal reception is pos-
sible, unstable, or impossible as shown in the diagram below.

Power
supply

Input

Impossible

Unstable

Possible

Impossible

Unstable

160 ms

0 to 90 ms

10 ms with
AC input type

0 to 500 ms

ON
OFF

Apply the power supply voltage through a relay or switch in such a
way that the voltage reaches a fixed value immediately.

Turn the power ON and OFF with relay with a rated capacity of 10 A
minimum to prevent contact deterioration due to inrush current
caused by turning the power ON and OFF.

Transistor Output

The transistor output of the H7CL is insulated from the internal cir-
cuitry by a photocoupler, so the transistor output can be used as
both NPN and PNP output.

AC Models

NPN Output

10

11

3

2

1

9

10

11

3

2

1

9

+

+

Load

Power supply for load

Power supply for load

PNP Output

Load

DC Models

NPN Output

PNP Output

1

2

3

4

5

1

2

3

4

5

+

+

Load

Load

Power supply for load

Power supply for load

Self-diagnostic Function

The following displays will appear if an error occurs.

Display

Error

Output

status

Correction

Set value

after

correction

Present
value
underflow
(see note)

No
change

Press RST
Key or reset
input

No change

e1

CPU

OFF

Press RST
Key or turn
power off

e2

Memory

and then
ON

0

Note:

Given when present value falls below the minimum value
(–999) in Down (decrement) Mode.

Operating Environment

When using the Counter in an area with excess electronic noise,
separate the Counter, wiring, and the equipment which generates
the input signals as far as possible from the noise sources. It is also
recommended to shield the input signal wiring to prevent electronic
interference.

Organic solvents (such as paint thinner), as well as very acidic or
basic solutions can damage the outer casing of the Counter.

Set Value Change

If the user changes the set value while the Counter is operating, the
user should be aware that the H7CL’s output will be ON when the set
value is the same as the present value.

Reset with a Set Value of 0

When the set value is 0, after the Counter is reset, the output is ON
(while reset, output is OFF).

Reset Time

It takes 1 ms or 20 ms (selectable) to turn the output OFF with the
following deflection ranges.

Time required for resetting

Deflection range

1 ms

0.8 to 1.2 ms (Reference value)

20 ms

15 to 25 ms (Reference value)

Output Delay

The following table shows the delay from when the present value
passes the set value until the output is produced.

Actual measurements in N and K modes.

Control output

Max. counting

speed

Output delay*

Contact output

30 cps

16.5 to 24.0 ms

5 kcps

3.7 to 5.6 ms

Transistor output

30 cps

12.0 to 20.0 ms

5 kcps

0.2 to 0.55 ms

*The variation in delays is due to different modes and conditions.

Flush Mounting

The H7CL’s panel surface is water-resistive (conforming to NEMA 4
(indoors) and IP66). In order to prevent the internal circuit from wa-
ter penetration through the space between the Counter and operat-
ing panel, attach a rubber packing (provided with the H7CL) be-
tween the Counter and operating panel and secure the rubber pack-
ing with the Y92F-30 flush-mounting adaptor.

ÉÉ

It is recommended that the space
between the screw head and the
adaptor should be 0.5 to 1 mm.

0.5 to 1 mm

Other

In case of performing a dielectric strength test, etc., on the H7CL
mounted to a control panel, disconnect the H7CL from the connect-
ing circuitry, or short-circuit all the terminals of the H7CL.
Otherwise the H7CL may be damaged.

Terminal 1 (power supply terminal) and terminal 6 (input common:
0 V for input) of DC model H7CL are internally connected to each
other.

Summary of Contents for H7CL Series

Page 1: ...th Shock Prevention Cover Contact output 100 to 240 VAC H7CL A 12 to 24 VDC H7CL AD H7CL AD 500 Transistor output Ph t l 100 to 240 VAC H7CL AS a s s o ou u Photocoupler 12 to 24 VDC H7CL ADS H7CL ADS 500 Accessories Order Separately Name Model Soft Cover Y92A 48F1 Hard Cover Y92A 48 Shock Prevention Cover for DC models only Y92A 48T Back Connecting Socket for flush mounting for AC models only P3G...

Page 2: ... 5 VDC 10 mA at 24 VDC P level for reference value Transistor output NPN open collector 100 mA max at 30 VDC max residual voltage 1 5 VDC max Reset system External min pulse width 1 ms 20 ms selectable manual and automatic internal according to C mode operation resets External power supply 50 mA at 12 VDC 10 Display 7 segment LEDs 12 mm high red LEDs for the present value and 8 mm high green LEDs ...

Page 3: ...z 0 75 mm single amplitude each in three directions Malfunction 10 to 55 Hz 0 5 mm single amplitude each in three directions Shock resistance Destruction 294 m s2 30G each in three directions Malfunction 98 m s2 10G each in three directions Ambient temperature Operating 10 C to 55 C 10 to 50 C if Counters are mounted side by side with no icing Storage 25 C to 65 C with no icing Ambient humidity Op...

Page 4: ... decrementing the present value but the output is on hold until reset OFF ON C Auto reset One shot Output Mode The Counter is automatically reset when counted up The control output is a one shot output type ON ON K Over count One shot Output Mode The Counter continues incrementing decrementing the present value but the output is a one shot output type Note Switches 1 to 6 are all set to OFF before...

Page 5: ...ate input Output 0 Reset input Set value Count input Gate input Output 0 Reset input t t K Mode Over count one shot output is ON Up Increment Mode Down Decrement Mode t Set value Count input Gate input Output 0 Reset input Set value Count input Gate input Output 0 Reset input t Note t one shot time 500 ms or 50 ms ...

Page 6: ...touts are as shown below according to DIN43700 1 0 A 48n 2 5 Note 1 The mounting panel thickness should be 1 to 4 mm 2 It is possible to mount Counters side by side but only horizontally 58 51 48 7 5 51 48 58 7 5 Y92S 29 rubber packing provided Panel Y92F 30 flush mounting adaptor provided P3GA 11 back connecting socket sold separately Y92S 29 rubber packing provided Panel Y92F 30 flush mounting a...

Page 7: ...H7CL H7CL 7 H7CL ADj 500 The cover conforms to finger protection standard against electric shock VDE 0106 P100 ...

Page 8: ...kΩ Internal circuitry Vin Supply voltage H7CL ADj DC Models IN 12 V 1 kΩ Internal circuitry IN Internal circuitry 5 V 4 7 kΩ Note No key input is effective while key protection input is ON Input Connections Open Collector Output Contact input Voltage Output 12 VDC 1 7 6 5 3 7 9 8 6 PLC or sensor 0 V Output 12 VDC PLC or sensor 0 V Output 7 6 5 3 7 9 8 6 AC models DC models 1 7 6 5 3 7 9 8 6 AC mod...

Page 9: ...DC Note When connecting a two wire sensor to a DC models sup ply 24 VDC 21 6 to 26 4 VDC to the Counter Key Protection Input 4 3 10 6 AC models DC models Open collector or contact 0 V Key protection input Key Protection Input ON impedance 1 kΩ max the leakage current is approx 1 mA when the impedance is 0Ω ON residual voltage 0 5 V max OFF impedance 100 kΩ min Maximum applied voltage 30 VDC max No...

Page 10: ...as paint thinner as well as very acidic or basic solutions can damage the outer casing of the Counter Set Value Change If the user changes the set value while the Counter is operating the user should be aware that the H7CL s output will be ON when the set value is the same as the present value Reset with a Set Value of 0 When the set value is 0 after the Counter is reset the output is ON while res...

Page 11: ...03527 Cat No L081 E1 1C OMRON Corporation Industrial Automation Company Measuring and Supervisory Controls Division 28th Fl Crystal Tower Bldg 1 2 27 Shiromi Chuo ku Osaka 540 6028 Japan Phone 81 6 6949 6035 Fax 81 6 6949 6069 In the interest of product improvement specifications are subject to change without notice Printed in Japan 0499 0 5C 0393 ...

Reviews: