H5BR
H5BR
7
Setting Item Table
Mode
Setting item
Discription
Setting procedure
Run mode
Set value
Compared to the present value.
Determines the timing of the
control output according to the
output mode.
Sequence when changing a digit using the incre-
ment
keys (1 to 4).
0
1
2
8
9
Batch count set
value
Turns ON the batch output when
the preset number of cycles have
been completed.
Sequence when changing a digit using the incre-
ment
keys (1 to 4).
0
1
2
8
9
Setting mode
Time range*
Determines the timing range.
Change the timing range with the increment keys (1 to 4).
UP/DOWN mode
Selects
Select UP/DOWN with the increment keys (1 to 4).
(UP)
(DOWN)
u
d
Output mode
Determines the form of the control
output. (Refer to the present value
vs. output diagrams on page 10 to
12.)
Sequence when changing the mode using the increment
keys (1 to 4).
a
a-1
a-2
a-3
b
b-1
d
e
f
Output time
Determines the duration of the
control output.
Will be displayed when the output
mode is A, A-1, A-2, A-3, b, or
b-1. Will not be displayed when
the output mode is d, E, or F.
Use keys 1 to 3 to change the value.
Key1 adjusts the first digit (0.1’s digit).
Key2 adjusts the second digit (1’s digit).
Key3 adjusts the third digit (10’s digit).
Key4 selects either hold output or one-shot output.
0
1
2
8
9
hold
0 0
.
s
Input signal time
Changes the duration of the
control and reset input signals.
Change the duration with the increment keys (1 to 4).
(1 ms)
(20 ms)
1
20
Key protect level
Locks certain keys to prevent
accidental operation. The key
protection level, kP-1 to kP-4,
determines which keys are locked
when the key protection input is
ON. The locked keys are crossed
out in the diagram on the right.
Sequence when changing the key protect level using the
increment keys (1 to 4).
4
1
2
3
p
p
p
p
<KP--1>
<KP--2>
<KP--3>
<KP--3>
Note:
1. Changes made in setting mode become effective when run mode is entered.
2. The time range setting appears first when setting mode is entered.