background image

16

Solid-state Timer

 

H3BA-N

Safety Precautions

Precautions for Safe Use

Please observe the following precautions for safe use of this product.

Environmental Precautions

Store the Timer within specified ratings.  If the Timer has been stored 
at -10°C or lower, let it stand for 3 hours or longer at room 
temperature before turning ON the power supply.

Use the Timer within the specified ratings for operating temperature 
and humidity.

Do not operate the Timer in locations subject to sudden or extreme 
changes in temperature, or locations where high humidity may result 
in condensation.

Do not use the Timer in locations subject to excessive dust, corrosive 
gas, or direct sunlight.

Do not use the Timer in locations subject to vibration or shock. 
Extended use in such locations may result in damage due to stress.

Install the Timer well away from any sources of static electricity, such 
as pipes transporting molding materials, powders, or liquids.

Usage Precautions

Install a switch or circuit breaker that allows the operator to 
immediately turn OFF the power, and label it to clearly indicate its 
function.

Pay careful attention to polarity to prevent wrong connections when 
wiring terminals.

Internal elements may be destroyed if a voltage outside the rated 
voltage is applied.

Maintain voltage fluctuations in the power supply within the specified 
range.

The Timer uses a transformerless power supply.  Do not touch the 
input terminals while the supply voltage is being applied, otherwise 
an electric shock may occur.

Precautions for Correct Use

Changing the Setting

Do not change the time unit, time range, or operation mode while the 
Timer is in operation, otherwise the Timer may malfunction.

Connecting the Operating Power 
Supply

The H3BA-N

@

 contains a capacitor-drop power circuit. Use a 

sinusoidal power supply with a commercial frequency. Do not use 
power supplies with a high frequency component (such as inverter 
power supplies) for Timers with 110 or 220-VAC specifications. Using 
these power supplies can damage internal circuits.

If voltages other than the rated voltage is applied, the internal 
components may be damaged. The internal element (varistor) will be 
damaged if a voltage of higher than 100 VAC is applied to the 24-
VDC line.

Connect the power supply voltage through a relay or switch in such a 
way that the voltage reaches a fixed value immediately or the Timer 
may not be reset or a timer error could result.

A DC power supply can be connected if its ripple factor is 20% or 
less and the mean voltage is within the rated operating voltage range 
of the Timer.

If the wiring to the terminal 2 (common terminal for both the power 
supply and input signals) is broken, the internal circuit will be 
destroyed.

Input/Output

An appropriate input will be applied to the input signal terminals of 
the Timer when one of the input terminals (terminals 5, 6, and 7) and 
the common terminal (terminal 2) for the input signals are short-
circuited. Do not attempt to connect any input terminal to any 
terminal other than the common terminal or to apply voltage across 
other than the specified input and common terminals or the internal 
circuits of the Timer may be damaged.

Note: 1.

Power supply terminal 2 is a common terminal for the input 
signals (G, S, R) to the Timer. Never use terminal 10 as the 
common terminal for this purpose, otherwise the internal 
circuit of the Timer may be damaged.

2.

Do not connect a relay or any other load between these two 
points, otherwise the internal circuit of the Timer may be 
damaged due to the high-tension voltage applied to the 
input terminals.

Minor electric shock may occasionally occur.  Do not 
disassemble the product or touch the interior of the Timer.

Minor burns may occasionally occur.  Do not touch the 
product while power is being supplied or immediately 
after power is turned OFF.

Minor fires may occasionally occur.  Tighten terminal 
screws to a torque of 1.08 N·m so that they do not 
become loose.

Minor electric shock may occasionally occur during 
operation.  Install the terminal cover.

Minor electric shock, fire, or malfunction may occasionally 
occur. 

Do not allow metal fragments, lead wire scraps, or chips 
from processing during installation to fall inside the Timer.

 

CAUTION

5,   6,   7
G,   S,   R

Input terminal

H3BA-N

2

10

Closed

Power supply 
AC or DC

Input contact

5,   6,   7
G,   S,   R

Input terminal

H3BA-N

(See note 2)

2 (see note 1)

10

Summary of Contents for H3BA-N

Page 1: ...forms to LR and approved by UL and CSA RC Broad Line up of H3B N Series H3B N Multi functional Timer H3BA N H3BA N8H Twin Timer Star delta Timer H3BG N8 H3BG N8H Power OFF delay Timer H3BH N8 H3BH N H3BG N H3BF N H3BA N Note Refer to the H3BF N BG N BH N Datasheet Cat No L094 E1 1 for details 11 pin model 8 pin with instantaneous contact output and time limit output 8 pin with instantaneous contac...

Page 2: ...ontact output Time limit SPDT and switchable SPDT time limit instantaneous 110 VAC 50 60 Hz H3BA N8H 110 VAC 220 VAC 50 60 Hz H3BA N8H 220 VAC 24 VDC H3BA N8H 24 VDC Name specifications Models Flush Mounting Adapters Y92F 30 Y92F 70 Y92F 71 Mounting Tracks 50 cm l 7 3 mm t PFP 50N 1 m l 7 3 mm t PFP 100N 1 m l 16 mm t PFP 100N2 End Plate PFP M Spacer PFP S Protective Cover Y92A 48B Track Mounting ...

Page 3: ...ntaneous Mounting method DIN track mounting surface mounting and flush mounting Approved standards UL508 CSA C22 2 No 14 Conforms to LR currently under application and approval is expected by the end of Feb 2006 Time unit s sec min h hrs 10 h 10 h Setting 1 2 0 05 to 1 2 0 12 to 1 2 1 2 to 12 3 0 3 to 3 3 to 30 12 1 2 to 12 12 to 120 30 3 to 30 30 to 300 Item H3BA N H3BA N8H Rated supply voltage S...

Page 4: ...th 0 75 mm single amplitude each in three directions Malfunction 10 to 55 Hz with 0 5 mm single amplitude each in three directions Shock resistance Destruction 1 000 m s2 approx 100G each in three directions Malfunction 100 m s2 approx 10G each in three directions Ambient temperature Operating 10 C to 55 C with no icing Storage 25 C to 65 C with no icing Ambient humidity Operating 35 to 85 Life ex...

Page 5: ...ut circuit AC DC input Power supply circuit Oscillation circuit Time range unit selectors Counting circuit Output circuit Output type selector Indicator circuit Power ON indicator Output ON indicator H3BA N8H Inputs Start Starts time measurement Reset Interrupts time measurement and resets time measurement value No time measurement is made and control output is OFF while the reset input is ON Gate...

Page 6: ...ht part within the plastic frame of the time setting knob Setting of Time Use the time setting knob to set the desired time Using the Setting Ring Setting a Specific Time Mount the Panel Cover on the Timer set the desired time with the time setting knob and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock ...

Page 7: ...relay NO 1 and 3 11 and 9 and output indicator Power indicator t t Basic operation Power Start Output t t t t t t t t t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay NC 1 and 4 11 and 8 Output relay NO 1 and 3 11 and 9 and output indicator Power indicator Basic operation Power Start Output t t t t t t t t t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 ...

Page 8: ... t t a t a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Power Start Output t Basic operation t t t t t a t a Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 11 and 8 NC Output relay NO Output indicator 1 and 3 11 and 9 Power indicator Power Start Gate Reset Output relay ON OFF ON OFF ...

Page 9: ... and 5 1 and 4 Output relay NO 8 and 6 1 and 3 and output indicator Power indicator t t Rt Rt t a Operating mode Timing chart H ON delay with instantaneous output contact Power Output t Basic operation Power 2 and 7 Output relay 8 and 5 NC Power indicator Instantaneous 1 and 4 output relay NC t t Rt Rt t a Instantaneous 1 and 3 output relay NO Output relay 8 and 6 NO output indicator ...

Page 10: ...Y92F 30 Flush Mounting Adapter 48 48 11 pins 15 6 63 7 0 7 39 dia 44 8 44 8 78 13 6 PW UP 48 48 8 pins 15 6 63 7 0 7 39 dia 44 8 44 8 78 13 6 PW UP Time setting ring Panel cover 50 16 5 50 42 dia Panel Cutout Note The mounting panel thickness should be 1 to 5 mm 0 5 R max 45 0 6 0 N 45 0 6 0 58 52 42 48 Panel P3G Back Connecting Socket sold separately PW UP ...

Page 11: ...nce value Flush Mounting Panel 88 58 45 0 15 45 0 15 Panel Cutout Adapter mounting hole Two 4 5 dia 52 to 53 76 0 2 65 to 66 R0 5 max PW UP Panel 43 0 2 58 50 0 2 0 56 68 R0 5 max 45 0 5 0 55 0 5 0 Note The mounting panel thickness should be 1 to 3 2 mm 45 0 2 PW UP 112 2 109 9 2 3 H3BA N P2CF 11 H3BA N8H P2CF 08 101 3 99 2 3 H3BA N Adapter Y92F 30 P3GA 11 91 4 15 H3BA N8H Y92F 30 P3G 08 15 86 4 ...

Page 12: ...M4 40 0 2 Eight M3 5 7 5 sems Two 4 5 dia holes 70 max 50 max 20 3 max 7 8 3 4 5 35 4 4 Two 4 5 dia holes Eleven M3 5 7 5 sems 70 max 50 max 31 2 max 7 8 3 4 5 35 4 4 P3G 08 P3GA 11 Terminal Arrangement Internal Connections Bottom View 45 27 dia 45 4 9 17 45 45 27 dia 25 6 4 5 16 3 6 2 PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 4 5 15 25 25 25 25 10 10 L 7 3 0 15 ...

Page 13: ...n three colors Use the most suitable type of Panel Cover with the design of the scaling plate according to the application When setting a given time for the Timer use of the Y92S 27 or Y92S 28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators The Time Setting Ring and Panel Cover should be used as a pair Hold down Clip PFP M 50 11 5 M4 8 pa...

Page 14: ...al timers are shown as follows The contact symbol of the H3BA N is ex pressed as follows because of its multiple op erating modes The instantaneous contacts of conventional timers are shown as follows Power supply MODE See note A H Note The output contact can be set to either instantaneous or time limit contact using the output type selector located at the upper right corner of the front panel ...

Page 15: ...hen OFF 200 kΩ min Use contacts which can adequately switch 0 1 mA at 5 V No contact Input Connection to NPN open collector output sensor Contact Input No contact Input Connection to a voltage output sensor 12 to 24 VDC sensor power supply Sensor Timer Start reset gate Input 0 V No 2 pin Operates with transistor ON DC power supply Timer Start reset gate Input 0 V No 2 pin Operates with relay ON 12...

Page 16: ...pplied the internal components may be damaged The internal element varistor will be damaged if a voltage of higher than 100 VAC is applied to the 24 VDC line Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately or the Timer may not be reset or a timer error could result A DC power supply can be connected if its ripple factor is...

Page 17: ... Timer in order to prevent the Timer from malfunction and damage A diode is an example of a surge absorbing element for DC circuits and a surge absorber is an example of a surge absorbing element for AC circuits Do not leave the Timer in time up condition for a month or longer in places with high temperatures otherwise the internal parts such as an electrolytic capacitor of the Timer may be damage...

Page 18: ...ia max multi conductor cable or 3 dia max insulated stranded wire for wiring When the Y92F 40 Y92F 70 or Y92F 71 Flush Mounting Adapter is used just insert the Timer into the square panel hole If the panel coating is too thick and the hooks do not click spread open the hooks appropriately to the left and right after inserting the Timer to the hole Dismounting Surface Mounting with P2CF Panel Mount...

Page 19: ...Solid state Timer H3BA N 19 ...

Page 20: ...LE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to ...