3 - 5
CompoNet Gateway Unit for CC-Link Operation Manual
3-
3 Wir
ing
3
3-3 Wiring
3-3-1 General Wiring Precautions
• Always turn OFF the power supply before performing any wiring operations on the Gateway Unit. The
external devices that are connected to the Gateway Unit may operate in an unexpected manner if the
Gateway Unit is wired while the power supply is ON.
• Be careful not to pinch your fingers when attaching connectors.
• Incorrect wiring will reduce safety functions. Perform all wiring correctly and confirm operation before
using the Gateway Unit.
3-3-2 Special Connector Tools
Special Screwdrivers
We recommend using the following Special Screwdrivers to tighten wiring screws when wiring the
power supply or connecting connector cables to connect accessories.
Model
Manufacturer (supplier)
XW4Z-00C
OMRON
SZF-1
Phoenix Contact