Flexible Safety Unit

Type G9SX-EX401-

Type G9SX-EX041-T-

USER'S MANUAL

Precaution for Safe Use

Indicates a potentially hazardous 
situation which, if not avoided, will 
resultin minor or moderate injury, or 
may result in serious injury or death. 
Additionally there may be significant  
property damage.

Meanings of Signal Words

The following signal words are used in this manual.

Alert Statements

Serious injury may possibly occur due to breakdown 
of safety outputs.
Do not connect loads beyond the rated value to the 
safety outputs.

Serious injury may possibly occur due to loss of 
required safety functions.
Wire G9SX properly so that supply voltages or 
voltages for loads do NOT touch the safety inputs 
accidentally or unintentionally.

Serious injury may possibly occur due to damages of 
safety inputs.
Apply protection circuitry against back electromotive 
force in case connecting inductiveloads to safety 
outputs.

Serious injury may possibly occur due to loss of 
safety functions.
Use devices appropriate for the application andthe 
condition where G9SX is used.

Indicates prohibited actions

Meaning of Alert Symbols

The following alert symbols are used in this manual.

Indicates mandatory actions

WARNING

WARNING

(1) Use G9SX within a enclosure with IP54 protection or higher of 

IEC/EN60529.

(2) Incorrect wiring may lead to loss of safety function.  Wireconductors 

correctly and verify the operation of G9SX before commissioning the 
system in which G9SX is incorporated. 

(3) Do not apply DC voltages exceeding the rated voltages, norany  AC 

voltages to G9SX.

(4) Use DC supply satisfying requirements below to prevent electric shock.

- DC power supply with double or reinforced insulation, for example, 

according to IED/EN60950 or EN50178 or a tranceformer 
according to IEC/EN61558.

- DC supply used satisfies the requirement for class 2 circuits or 

limited voltage/current circuit stated in UL 508.

(5) Auxiliary error output is NOT safety outputs.

Do not use auxiliary error output as any safety output.
Such incorrect use causes loss of safety function of G9SX andits 
relevant system.

(6) After installation of G9SX, qualified personnel should confirm the 

installation, and should conduct test operations and maintenance.
The qualified personnel should be qualified and authorized to secure 
the safety on each phases of design, installation, running, 
maintenance and disposal of system.

(7) A person in charge, who is familiar to the machine in which G9SX is to 

be installed, should conduct and verify the installation.

(8) Turn OFF the signal to Safety input or Logical AND connection input 

every 24hours and make sure G9SX operates without faults by 
checking the state of the ERR indicator.

(9) Do not dismantle, repair, or modify G9SX.  It may lead to loss of  its 

safety functions.

(10) Use only appropriate components or devices complying with relevant 

safety standards corresponding to the required level of safety 
categories. 
Conformity to requirements of safety category is determined as an 
entire system. 
It is recommended to consult a certification body regarding 
assessment of conformity to the required safety level.

(11) OMRON shall not be responsible for conformity with any safety 

standards regarding to customer's entire system.

(12) Disconnect G9SX from power supply when wiring, to prevent electric 

shock or unexpected operation.

(13) Be cautious not to have your fingers caught when attaching terminal 

sockets to the plugs on G9SX.

(14) The lifetime of G9SX depends on the conditions of switching of its 

outputs. Be sure to conduct its test operation under actual operating 
conditions in advance and use it within appropriate switching cycles 

(15) Do not use in combustible gases or explosive gases. Arcs or heat 

generated by switching elements of G9SX can lead to fire or 
explosion.

Precaution for Safe Use

(1) Handle with care

Do not drop G9SX to the ground or expose to excessive vibration or 
mechanical shocks. G9SX may be damaged and may not function 
properly.

(2) Conditions of storage

Do not store in such conditions stated below.

1) In direct sunlight
2) At ambient temperatures out of the range of -10 to 55

 

3) At relative humidity out of the range of 25 to 85% or under such  
    temperature change that causes condensation.
4) In corrosive or combustible gases
5) With vibration or mechanical shocks out of the rated values.
6) Under splashing of water, oil, chemicals
7) In the atmosphere containing dusts, saline or metal powder 

             G9SX may be damaged and may not function properly.
(3) Mounting

Mount G9SX to DIN rails with attachments (TYPE PFP-M, not 
incorporated to this product), not to drop out of rails by vibration etc. 
especially when the length of DIN railing is short compared to the 
widths of G9SX.

Precautions for Correct Use

(4) Following spacing around G9SX should be available to apply rated 

current to outputs of G9SX and for enough ventilation and wiring:

a) At least 25 mm beside side faces of G9SX.
b) At least 50 mm above top face of G9SX and below bottom face of 

G9SX.

c) At least 25 mm between side face of Advanced unit (G9SX- 

AD322-

-

) and side face of Expansion unit (G9SX-EX401-

 or 

G9SX-EX041-T-

).

(5) Wiring

1) For model G9SX-

Use the following to wire to G9SX-

.

- Solid wire: 0.2 to 2.5mm

2

 AWG24 to AWG12

- Stranded wire (Flexible wire): 0.2 to 2.5mm

2

 AWG24 to AWG12

Strip the cover of wire no longer than 7mm.

2) For model G9SX-

-RT (with screw terminals)

  Tighten each screw with a specified torque of 0.5 to 0.6N

m, or 

  the G9SX-

 may malfunction or generate heat.

(6) When connecting Expansion Units to Advanced Unit
     (TYPE G9SX- AD322-

-

):

1) Follow the procedure below:

a) Remove the termination connector from the receptacle on 

Advanced Unit (TYPE G9SX-AD322-

-

),

b) Insert the head of the connecting cable of Expansion Unit to the 

receptacle on the Advanced Unit 

c) Set the termination connector to the receptacle on the 

Expansion Unit at the end position. When Advanced Unit is used 
as without expansion units, leave the terminination connector set 
on the Advanced Unit.

2) Do not remove the termination connecter while the system is 

operating.

3) Before applying supply voltage, confirm that the connecting sockets 

and plugs are locked firmly.

4) All of the Expansion Units should be supplied with its specified 

voltages within 10s after the connected Advanced Unit is supplied 
with voltage.
Otherwise, Advanced Unit detects the power-supply error for the 
Expansion Units.

(7) Start entire system after more than 5s have passed since applying 

supply voltage to all G9SXs in the system.

(8) G9SX may malfunction due to electro-magnetic disturbances. 

Be sure to connect the terminal A2 to ground.

(9) Devices connected to G9SX may operate unexpectedly. 

When replacing G9SX, disconnect it from power supply.

(10) Adhesion of solvent such as alcohol, thinner, trichloroethane or 

gasoline on the product should be avoided. Such solvents make the 
marking on G9SX illegible and cause deterioration of parts.

(11) Do NOT mix AC load and DC load to be switched in one G9SX-EX-

.

When switching of both AC load and DC load is ncessary, connect 
more than two G9SX-EX-

 and use each unit for AC load and DC 

load exclusively.

(12)This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 
measures to reduce interference.

25mm min.

25mm min.

ED

PWR

A2

X2

44

34

24

14

A1

33

43

13

23

No.

G9SX-EX
24VDC

ED

PWR

A2

X2

44

34

24

14

A1

33

43

13

23

No.

G9SX-EX
24VDC

G9SX-BC202
24VDC

No.

T1

T2

FB

ERR

EI

PWB

L2

L1

S24

S14

A2

X2

T22

T21

A1

X1

T12

T11

Y1

T32

T33

T31

No.

OFF-DELAY

0.5

0.4

0.3

0.2

15

10

7

5

4

3

2

1.5

1

0.6

0.7

0

S54

S44

S34

S24

S14

L1

A2

T42

T41

T22

T21

A1

X2

X1

Y1

T12

T11

T33

T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T15
24VDC

50mm min.

50mm min.

Appearance and Explanation of Each Parts

1

TYPE G9SX-EX041-T-

TYPE G9SX-EX401-

(Expansion Unit)

(Expansion Unit: Off-delay Model)

TYPE G9SX-EX041-T-

TYPE G9SX-EX401-

(Expansion Unit)

(Expansion Unit: Off-delay Model)

EI

PWR

A2

X2

44

34

24

14

A1

33

43

13

23

No.

G9SX-EX401
24VDC

ED

PWR

A2

X2

44

34

24

14

A1

33

43

13

23

No.

G9SX-EX041-T
24VDC

Power Supply Input 

terminal (+)

Power Supply Input 

terminal (-)

Auxiliary Error

output terminal

Auxiliary Error

output terminal

Safety relay contact

output terminals

Safety off-delay

relay contact

output terminals

Safety off-delay

relay contact

output terminals

Safety relay contact

output terminals

43

33

23

13

PWR

44

A2

14 24

A1

34

X2

EI

ERR

Terminal arrangement and LED indicators

Power Supply Input 

terminal (+)

Power Supply Input 

terminal (-)

LED Indicators

Connect the power supply 
plus to the A1 terminal.
Connect the power supply 
minus to the A2 terminal.

The outputs synchronize 
with safety outputs of  
Advanced unit. 

Outputs during error 
indicator is lighting up.

Wiring of inputs and outputs

Signal
name

Safety
relay
output

Power
supply
input

Terminal
name

13-14,
23-24,
33-34,
43-44

A1,
A2

Auxiliary
error
output

X2

Wiring

Description of operation

The input terminals
for power supply.
Connect the power
source to A1 and A2
terminals.

Keep these outputs Open
when NOT used.

Keep these outputs Open
when NOT used.

TYPE G9SX-EX401-

/ TYPE G9SX-EX041-T-

Internal Connection

2

A2

X2

Power

supply

circuit

Auxiliary

outputs

control

Safety

outpus
control

A1

K1

13 23 33 43

14 24 34 44

K2

Exp.

sig.

IN

Exp.

sig.

OUT

*1 Internal power supply circut is not isolated.
*2 Relay outputs are isolated

*1

*2

Dimensions

3

*Note2

*Note2

100 max.

(6)

(6)

115 max.

23 max.

*Note1 Above outline drawing is for -RC terminal type.
*Note2 For -RC terminal type only.

(22.5)*

Typical dimension

Ratings and Specifications

4

Ratings

Endurance

Outputs

Rated supply voltage

Electrical
endurance

5,000,000 cycles Min. 
(Switching frequency: 7,200 cycles/hour)

Isolation specification

Item

Note1: Not including Operating time or Response time of G9SX-AD322-

-

 (Advanced Unit).

Note2: Both G9SX-EX401-

 (Expansion Unit) and G9SX-EX401-T-

 (Expansion Unit: Off-delay Model) can be connected in the same system.

Note3: Not including accuracy of release time of the relays.
Note4: Off-delay time setting is applied from Advanced Unit.

PNP transistor output, 
Load current: 100mA Max.

Auxiliary output

Specifications and Performance

Item

Over voltage category (IEC/EN 60664-1)

G9SX-EX401-

G9SX-EX041-T-

II  (safety relay outputs 13 to 43, 14 to 44 : III)

Operating time (OFF to ON state) (See Note1)

30ms Max.

10ms Max.

Maximum number of connectable units (See Note2)

5 units Max.

Accuracy of Off-delay time (See Note3)

-

Within plus or minus 5% of the set value (See Note4)

G9SX-EX401-

/G9SX-EX041-T-

24VDC

-15% to +10% of rated supply voltage

2W  Max.

250VAC 3A / 30VDC 3A
(resistive load) 

3A

250VAC , 125VDC

Vibration resistance

Frequency: 10 to 55 to 10 Hz, Amplitude: 0.375mm half amplitude (0.75mm double amplitude)

Mechanical shock resistance

300 m/s

2

  (destruction), 100m/s

2

  (malfunction)

Ambient temperature

-10 to +55

(No freezing or condensation)

Ambient humidity

25

85

RH

Terminal tightening

0.5 Nm  (Applicable  only to TYPE G9SX-

-RT:screw terminal model)

Weight

Approx. 145 g

100Mohm Min. (by 500VDC megger)

Insulation resistance

Dielectric strength

1200VAC  1min

2200VAC  1min

Between all terminals connected together and DIN rail

Between different poles of outputs

Between Safety relay outputs connected together
and other terminals  connected together.

Between all terminals connected together and DIN rail

Between different poles of outputs

Between Safety relay outputs connected together
and other terminals  connected together.

Response time (ON to OFF state) (See Note1)

Of-delay time

KM1,KM2  NC contact

KM3

KM6  NC contact

KM1,KM2  NO contact

KM3

KM6  NO contact

Operation command
Rotation of motor

S14

A2

S24 S34 S44 S54 L1

X1 X2

T11

A1

T12 T21 T22 T31 T32 T33 Y1

T41

T42

KM2

KM6

KM1

+24V

+24V

Feedback Loop

+24V

KM1

KM5

KM6

KM2

KM3 KM4

Limit switch S2

Safety limit switch S1

Operation
command

M1

KM2

KM1

M3

KM6

KM5

M2

KM4 

KM3

Motor controller

OFF

AND

PLC etc.

Timing chart

open

23

24

11

12

S2

S1

GND

S1
S2
KM1

KM6

M1

M3

:Safety limit switch
:Limit switch
:Contactor
:3-phase motor

Devices

G9SX-AD322-

G9SX-EX041-T

Control circuit

Control

circuit

NC

NC

NC

A2

X2

A1

K1

13 23 33 43

14 24 34 44

K2

Note1: This example is corresponding to category 4(EN 954-1)

S34

Examples of application

5

Application and timing chart

Category of EN 954-1, ISO13849-1

6

In the condition shown in '5.Examples of Application' on this paper, 
G9SX can be used for the corresponding categories up to

 

category 

4 per EN954-1 and performance level(PL) up to e per ISO13849- 1.
This does NOT mean that G9SX can always be used for required 
category under all the similar conditions and situations.
Conformity to the categories must be assessed as a whole system.
When using G9SX for safety categories, be sure to confirm the 
conformity as a whole system.

For use of Safety category 4, fuses of 3.15A current rating should be 
connected to safety relay outputs to prevent welding of the contacts.

Fault Detection

7

ERR

indicator

Light up

Conditions

Expected causes 
of the faults
Replace with a 
new product.

When G9SX detects a fault, ERR indicator lights up to show the 
information of the fault.
Check and take needed measures referring to the following table. 
And then apply supply voltage to G9SX.

English

Suitability for Use

OMRON shall not be responsible for conformity with any 
standards, codes, or regulations that apply to the combination of 
the products in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the 
product for the systems, machines, and equipment with which it 
will be used.  Know and observe all prohibitions of use applicable 
to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT 
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE 
RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.

EU Declaration of Conformity

Standards

OMRON declares that G9SX is in conformity with the 
requirements of the following EU Directives:
  - EMC Directive 2004/108/EC
  - Machinery Directive 2006/42/EC

G9SX is designed and manufactured in accordance with the 
following standards:
  - EN954-1 Category 4,
  - EN ISO13849-1:2008 Category 4 PL e,
  - IEC/EN61508 SIL3,
  - IEC/EN61000-6-2, 

- IEC/EN61000-6-4, 

 

  - UL508, 

 

- UL1998,

  - CAN/CSA C22.2 No.142

Original instructions

OMRON  EUROPE  B.V. (Importer in EU)

Wegalaan  67-69, NL-2132  JD  Hoofddorp THE NETHERLANDS
PHONE  31-2356-81-300   FAX 31-2356-81-388

OMRON  SCIENTIFIC TECHNOLOGIES INC.

6550 Dumbarton  Circle,  Fremont  CA  94555-3605  U.S.A
PHONE  1-510-608-3400   FAX 1-510-744-1442

OMRON  ASIA PACIFIC  PTE. LTD.

438A  Alexandra  Road  # 05-05/08,
Alexandra  Technopark  Singapore  119967 SINGAPORE
PHONE  65-6-835-3011   FAX 65-6-835-2711

Note: Specifications  subject  to  change  without  notice.

OMRON  Corporation 

(Manufacturer)

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN

OMRON  (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
PHONE  86-21-5037-2222   FAX 86-21-5037-2200

Thank you for purchasing G9SX Flexible Safety Unit.
Please read and understand this manual before using the products.
Keep this manual ready to use whenever needed.
Only qualified person trained in professional electrical technique
should handle G9SX.
Please consult your OMRON representative if you have any
questions or comments.
Make sure that information written in this document are delivered to 
the final user of the product.

Marking

Function

Name

Color

PWR

Lights up while power is supplied.

Power Supply
Indicator

Green

ERR

Lights up when an error occurs.
For details refer to
'7. Fault Detection'.

Error  Indicator

Red

EI

Lights up while Safety relay 
outputs are in ON-state.

Safety Output
Indicator

Orange

ED

Lights up while Off-delayed 
relay outputs are in ON-state.

Off-delayed Safety
Output Indicator

Orange

(Expansion Unit / Expansion Unit of-delay model)

43

33

23

13

PWR

44

A2

14 24

A1

34

X2

ED

ERR

Item
Power
input

Operating voltage
range

Rated carry current

Rated power
consumption

Maximum switching
voltage

Rated load

G9SX-EX401-

/G9SX-EX041-T-

100,000 cycles Min.
(Rated load, Switching frequency: 1,800 cycles/hour)

Item

Mechanical
endurance

G9SX-EX401-

/G9SX-EX041-T-

G9SX-AD322-

 (24VDC) + G9SX-EX041-T (24VDC)

(2-channel safety limit switch inputs / Auto reset)

Faults involved with 
Safety relay outputs 
of Expansion Units

Expected causes 
of the faults
1) Welding of relay 
    contacts
2) Failures of the 
    parts of the 
    internal circuits

0631678-0 F