background image

Designation

1

Internal connection

Application examples

2

External Physical Dimensions

3

5

Output terminals

Power input terminal

Output terminals

Power input terminal

OFF-delay time 
setting switch
(Only for G9SA-321-T

)

Earth terminal

Refer to the product marking.

I/O terminals

Input power
indicator

Relay operation 
indicator

6

Type G9SA can construct the condition conforming to PL=e and category 4 requested with by EN 
ISO13849-1 European standard. (The part of off-delay output of G9SA-321-T

 can construct PL=d 

and  category  3.) This  category  class  is  recognised  and  based  on  the  circuits  we  made,  so  we 
would  like  you  to  conform  the  category  class  with  G9SA  at  your  application  once.  Category  is 
judged by the condition of the whole control system.

 A condition for calculation of performance level 

(EN 

ISO13849-1

- Category 4 (The part of off-delay output of G9SA-321-T

: Category 3)

- DCavg: High (The part of off-delay output of G9SA-321-T

: Low)

- CCF: Min 65 points

- MTTFd: G9SA-301

113 years, G9SA-501

 37 years, G9SA-321-T

□:

 32 years, G9SA-TH301

 86 years

   * MTTFd is a value calculated based on the following operation conditions.  

   

- Nop=31,680 cycles/year (dop=220 days/year

 hop=12 hours/day

 t cycle=300 seconds/cycle)

 In order to be category 4 (EN ISO13849-1)

  1. 2 channels are needed to external input at T11-T12, T21-T22.
  2. The switch at T11-T12, T21-T22 should be constructed with positive open form. In case of
      using limit switch, another one is requested positive open construction type.
  3. The NC contact from a contactor is require to feed back signal T31-T32. 
      (Refer to the application examples.)
  4. PE terminal should be dropped to earth.
  5. Automatically start (Auto-reset mode) must be prevented through the superordinate control.

Failure detection

7

K1(K3) and K2(K4)
LED do not turn on.

Failures of the parts
of the internal circuits

Replace with a new product.

Failures involving the wiring of
External input (input line)

Failure indication
by LED

Failure condition

K1(K3) or K2(K4)
LED does not turn
on.

Power LED
does not turn on.

Type G9SA can detect the failure for the safety of internal circuit, parts condition and external 
wiring.

(1) When ready for wiring, the power source should be disconnected first. Further, at operating this unit, the

     terminal cover should be closed correctly in order to prevent an electrical shock.

(2) Do not wire in case threat of Lightning. otherwise an electric shock may occur.
(3) Do not apply any excessive voltage or current to the input or output circuit the G9SA. Doing so may result in

     damage to the G9SA or cause a fire.

(4) Do not apply any variable voltage, otherwise G9SA may malfunction. 
(5) Do not connect any overload to the output circuit, otherwise the G9SA in operation  will generate excessive

     heat and the output elements of the G9SA may short-circuit  or fire may result.

(6) The lifetime of G9SA depends on the conditions of switching of its outputs. Be sure to conduct its test

     operation under actual operating conditions in advance and use it within appropriate switching cycles. 
     Change the G9SA  before expected operation. Over operation may cause may short-circuit or may 
     malfunction.

(7) Do not operate the G9SA with flammable or explosive gass. An arc with operation and the heat of relay will

     cause a fire or an explosion.

(8) Do not disassemble, repair, or modify the G9SA, otherwise an electric shock may occur or the G9SA may

     malfunction.

(9) Use protective device (Fuse of 5A current rating etc) for short-circuit protection and ground fault protection,

     otherwise a fire may occur or the G9SA may malfunction.

Precautions for Safe Use

(1) For malfunctions in case that the power supply picks up gradually.

     Malfunctions in case that the power supply picks up gradually. In case that the input circuits close before the
     power supplies, internal logic may malfunction. 

(2) Handling

     1. Do not drop the G9SA or shock or vibrate the G9SA excessively. Doing so may result in damage to the
         G9SA or cause G9SA to malfunction.
     2. Do not turn the off-delay setting volume switch of G9SA-321-T

 less than the MIN value or more than

         the MAX value. Otherwise the G9SA may be failed.

(3) For adhesion of solvent

     Adhesion of solvent, likely Alcohol, Thinner, Trichloroethane, Gasoline, on the product should be prohibited.
     Such solvent cause erasing the marking and being inferior of the parts.

(4) Operating and Storage Environment

     Do not operate or store the G9SA under the following conditions.
     Doing so may result in damage to the G9SA or cause the G9SA to malfunction.
      1. The places with direct sunlight.
      2. The places with ambient temperature ranges not within -25 to 55

.

      3. The places with rapid temperature changes resulting in condensation or relative humidity ranges not
          within 35 to 85%RH. 
      4. The places with atmospheric pressure out of the range 86 to 106kpa.
      5. The places with corrosive or inflammable gas.
      6. The places with water, oil, or chemical sprayed on the G9SA.
      7. The places with  vibration or shock affecting the G9SA.
      8. The places with atmosphere containing dusts, saline or metal powder.

(5) Mounting multiple units 

     When mounting multiple units close to each other, the rated current will be 3A. Do not apply a current 
     higher than 3A.

(6) For feedback purpose use devices with contacts capable of switching  micro loads of 24VDC, 5mA.
(7) The Safety input OFF signal for T11/T12 (or T23) and T21/T22 terminals must be longer than the response 

     time (10ms). Otherwise, the G9SA will be locked out or will not be able to be started or restarted.
     Also, a shorter safety input OFF signal might cause the G9SA to be locked. In this case, all safety inputs 
     must be turned off or the power supply for G9SA must be off before restarting the G9SA.

(8) Wiring

     1. Use the following to wire the G9SA.
         - Stranded wire (Flexible wire): 0.75 to 1.5mm

2

         - Solid wire: 1.0 to 1.5mm

2

     2. The G9SA may malfunction or generate heat.
         - Tighten each screw to a torque of 0.78 to 1.18N

m,

     3. External inputs connected to T11 and T12 or T21 and T22 of the G9SA must be no-voltage contact inputs.
     4. PE is a ground terminal. When machine is grounded at the positive, the PE terminal should not be
         grounded.

(9) This is a class A product. In residential areas it may cause radio interference, in which case the user may be

     required to take adequate measures to reduce interference.

(10) Mounting Expansion units

       When an Expansion Unit is being used, remove the connector cover from the G9SA Master Units and insert  
       the connector of the Expansion Unit's connector cable. Make sure that the connector is correctly locked
       before operating.

Precautions for Correct Use

Aug. 2010

Thank you for purchasing G9SA Safety Relay Unit.
Please read and understand this manual before using the products.
Keep this manual ready to use whenever needed. 
Only qualified person trained in professional electrical technique should handle G9SA.
Please consult your OMRON representative if you have any questions or comments.
Make sure that information written in this document are delivered to the final user of the product.

USER'S MANUAL

Type G9SA-301

Safety Relay Unit

Type G9SA-501

Type G9SA-321-T

Type G9SA-TH301

24VAC/DC

Specifications

4

Type for G9SA-321-T

-T015

1.5s

7.5s

15s

30s

MAX. Off-delay time / 15 steps

 Off-delay time

-T075

-T15

-T30

 Characteristics

Operating time

30ms MAX.

10 to 55Hz  0.375mm single amplitude 
(0.75mm double amplitude)

Destruction: 300m/s

2

Malfunction: 100m/s

2

Ambient humidity

Ambient temperature

Shock resistance

Vibration resistance

Response time

35 to 85%RH

-25 to 55

10ms MAX.

 Protection class

IP20

Enclosure

Terminals

IP40

G9SA-301: Twenty, M3
G9SA-501: Twenty-four, M3
G9SA-321-T

: Twenty-four, M3

G9SA-TH301: Twenty-one, M3

111 MAX.

Type G9SA-301

Type G9SA-501
Type G9SA-321-T

Type G9SA-TH301

43

63

76 MAX.

9

7×5

35

45 MAX.

R2.3

5.6

9

4.6 dia.

35±0.3

84±0.3

Two, 4.2 dia. or M4

 G9SA-301  Limit Switch Input 2ch / Auto-reset

open

S1

S2

23

24

11

12

KM1

KM2

KM1

KM2

Feedback loop

M

KM1

KM2

A1 A2

T12

T11

T31

T32

13 23 33 41

14 24 34 42

A

B

T21

T22

PE

T23

K1

K2

a
b

a

b

K1

K2

K1

K2

2
5

6

1

3
4

TH

SA

1

2

3

4

5

6

JP

 G9SA-501  Limit Switch Input 2ch / Manual-reset

S1

11

12

KM1

KM2

S3

KM1

KM2

M

S2

23

24

KM1 KM2

open

A1 A2

T12

T11

T31

T32

A

B

T22

PE

T23

K1

K2

a

b

a

b

K1

K2

K3

K4

2

5

6

1

3
4

Control

Circuit

K3

K4

K1

K2

13 23 33 43

14 24 34 44

53 61

54 62

TH

SA

T21

Feedback loop

1

2

3

4

5

6

JP

 G9SA-321-T

  Limit Switch Input 2ch / Manual-reset

S1

11

12

KM1

KM2

Feedback loop

S3

S2

23

24

KM1 KM2

open

KM1

KM2

M

Motor

Controller

A1 A2

T12

T11

A

B

T21

T22

PE

T23

13

23 33 43

14 24 34 44

53 61

54 62

K1

K2

a

b

a

b

K1

K2

K1

K2

6

1

3
4

Control

Circuit

K3

K4

K3

K4

Off Delay

Timer

2

5

T31

T32

TH

SA

Operation instruction

1

2

3

4

5

6

JP

 G9SA-TH301 with 2-hand Input

S11

S12

KM1

KM2

KM1

KM2

Feedback loop 

1
2
3
4
5
6

K1

K2

Control Circuit

6

1

3
4

2

5

K1

K2

TH

SA

JP

*1) Safety outputs  *2) Non-safety outputs
*3) When the inputs of G9SA-321-T

 are restored during off-delay time,

      G9SA-321-T

 will operate as below. depending on the reset mode.

      - Auto reset mode: Outputs turn off after off-delay time, then immediately turns on.
      - Manual reset mode: Outputs turn off after off-delay time, then turn on when reset input is given. 

24VDC

AC15
DC13

1.7W MAX.

2.6W MAX.

3.3W MAX.

250VAC 5A  cos

φ

=1   30VDC 5A  L/R=0ms

240VAC 2A  cos

φ

=0.3   

24VDC 1A  L/R=48ms   

5A (1 Output)

IEC60947-5-1
Table 4

 Ratings

Rated carry current
Max. switching voltage

Rated load

Rated power 
consumption

24VAC

1.8VA MAX.

2.8VA MAX.

3.5VA MAX.

250VAC  125VDC

G9SA-301/TH301

G9SA-501

G9SA-321-T

13/14,23/24,33/34

41/42

61/62

61/62

13/14,23/24,33/34

43/44,53/54

13/14,23/24,33/34

43/44,53/54

N.O. contacts   *1)

3 N.O.

---

---

1 N.C.

1 N.C.

1 N.C.

3 N.O.

2 N.O.

5 N.O.

Off-delay contacts  *1) *3)

N.C. contacts  *2)
Auxiliary contacts 

English

13 23 33

41

14 24 34

42

T11 T12 T31 T32 T23 A1

T21 T22 A

B PE A2

13 23 33

41

14 24 34

 

42

T11 T12 T13 T31 T32 A1

T21 T22 T23   PE A2

13 23 33 43 53 61

14 24 34 44 54 62

T11 T12 T31 T32 T23 A1

T21 T22 A

B PE A2

I/O terminals

5.9

10.5

91

Rated supply voltage
Operating voltage range

24VAC / 24VDC

-15% to +10% of rated supply voltage

Input

Output

 Pollution degree

3
2

External
Internal

Checking points and measures
to take 

Failures involving the wiring of
External input (input line)

Failures of the parts of the
External devices (Contactor etc)

Failures of the parts
of the internal circuits

Replace with a new External devices.
(Contactor etc)

Failures of the parts
of the internal circuits

Replace with a new product.

Supply voltage outside
the rated value

Check the supply voltage to
Expansion.

Failures involving the wiring of
External input (output line)

Replace with a new product.

Check the wiring to External input.
(input line) 

Check the wiring to External input.
(output line) 

Check the wiring to External input.
(input line) 

Failures of the parts of the
Protective device (Fuse etc) 

Replace with a new Protective device.
(Fuse etc) 

All LED turn on.
but the safety 
output doesn't on. 

Control

Circuit

T13 T11 T12

A1

A2

T31 T32

13

33

41

23

 

 

14

24

34

42

T21 T22

PE

T23

WARNING

Precaution for Safe Use

Indicates a potentially hazardous situation which, if not 
avoided, will result in minor or moderate injury, or may
result in serious injury or death. 
Additionally there may be significant property damage.

Meanings of Signal Words

The following signal words are used in this manual.

Meaning of Alert Symbols

The following alert symbols are used in this manual.

Serious injury may possibly occur due to breakdown of safety outputs.
Do not connect loads beyond the rated value tothe safety outputs.
Serious injury may possibly occur due to loss of required safety functions.
Wire G9SA properly so that supply voltages or voltages for loads do NOT 
touch the safety inputs accidentally or unintentionally.

WARNING

Alert Statements

Indicates prohibited actions

Indicates mandatory actions

Mounting holes

EU Declaration of Conformity

Standards

OMRON declares that G9SA series are in conformity with the requirements of 
the following EU Directives:
   - EMC Directive: 2004/108/EC
   - Machinery Directive: 2006/42/EC

G9SA series are designed and manufactured in accordance with the following 
standards:
   - EN ISO13849-1: 2008  PL e  Category 4 
   - EN 574: 1996/A1: 2008 (G9SA-TH301 only)
   - EN 60947-5-1: 2004
   - UL508, CAN/CSA C22.2 No.14

KM1

KM2

M

Original instructions

 Life expectancy

Electrical endurance

Mechanical endurance

100,000 operations MIN.  Rated load
Switching frequency 1,800 operations/h
5,000,000 operations MIN.
Switching frequency 7,200 operations/h

Insulation resistance

Dielectric strength

Between different poles of output

 Isolation specification

Between different poles of output

Between inputs and outputs

Between inputs and outputs

100Mohm MIN.
(by 500VDC Megger)

2,500VAC 1min.

Connector cover

5

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product.
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.  Know and 
observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK 
TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE 
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE 
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Suitability for Use

OMRON  EUROPE  B.V. 

(Importer in EU)

Wegalaan  67-69, NL-2132  JD  Hoofddorp
THE NETHERLANDS
PHONE  31-2356-81-300   FAX 31-2356-81-388

2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON  ASIA PACIFIC  PTE. LTD.

438A  Alexandra  Road  # 05-05/08,
Alexandra  Technopark  Singapore  119967
SINGAPORE
PHONE  65-6-835-3011   FAX 65-6-835-2711

Note: Specifications  subject  to  change  without  notice.

OMRON  Corporation 

(Manufacturer)

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530
JAPAN

OMRON  (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
PHONE  

86-21-5037-2222 / FAX 86-21-5037-2200

For performance level safety category 

(EN ISO13849-1)

Limit switches S1 and S2

K1,K2,K3,K4  (NC)

K1,K2,K3,K4  (NO)

KM1,KM2 (NC)

KM1,KM2 (NO)

Reset switch S3

Limit switches S1 and S2

Reset switch S3

Operation instruction

K1,K2 (NC)

K1,K2 (NO)

K3,K4 (NC)

K3,K4 (NO)

KM1,KM2 (NC)

KM1,KM2 (NO)

Motor rotation

OFF-delay time

S11 (NO)

S11 (NC)

S12 (NC)

S12 (NO)

KM1,KM2 (NC)

KM1,KM2 (NO)

MAX. 0.5s

K1,K2 (S)

K1,K2 (ö)

KM1,KM2 (ö)

KM1,KM2 (S)

Positionsschalter S1 und S2

1,000A

Rated conditional short-circuit current 

0622108-9 J

OMRON ELECTRONICS LLC

Reviews: