Single-phase Solid State Relays for Heaters
G3PE
Specifications
■
Ratings
Input (at an Ambient Temperature of 25
°
C)
Output
*
The applicable load current depends on the ambient temperature. For details, refer to
Load Current vs. Ambient Temperature
■
Characteristics
Item
Model
Rated voltage
Operating voltage range
Rated input current
Voltage level
Must operate voltage
Must release voltage
G3PE-
@@@
B
12 to 24 VDC
9.6 to 30 VDC
7 mA max.
9.6 VDC max.
1.0 VDC max.
G3PE-
@@@
BL
15 mA max.
Model
G3PE-215B(L) G3PE-225B(L) G3PE-235B(L) G3PE-245B(L)
Item
Rated load voltage
100 to 240 VAC (50/60 Hz)
Load voltage range
75 to 264 VAC (50/60 Hz)
Applicable load current
*
0.1 to 15 A
(at 40
°
C)
0.1 to 25 A
(at 40
°
C)
0.5 to 35 A
(at 25
°
C)
0.5 to 45 A
(at 25
°
C)
Inrush current
150 A
(60 Hz, 1 cycle)
220 A
(60 Hz, 1 cycle)
440 A
(60 Hz, 1 cycle)
Permissible I
2
t
(reference value)
121A
2
s
260A
2
s
1,260A
2
s
Applicable load
(resistive load)
3 kW
(at 200 VAC)
5 kW
(at 200 VAC)
7 kW
(at 200 VAC)
9 kW
(at 200 VAC)
Model
G3PE-215B
G3PE-225B
G3PE-235B
G3PE-245B
G3PE-215BL
G3PE-225BL
G3PE-235BL
G3PE-245BL
Item
Operate time
1/2 of load power source cycle + 1 ms max.
1 ms max.
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
10 mA max. (at 200 VAC)
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track)
Shock resistance
Destruction: 294 m/s
2
(Mounted to DIN track)
Ambient storage temperature
−
30 to 100
°
C (with no icing or condensation)
Ambient operating
temperature
−
30 to 80
°
C (with no icing or condensation)
Ambient operating humidity
45% to 85%
Weight
Approx. 240 g
Approx. 400 g
Approx. 240 g
Approx. 400 g