Omron G3PC Datasheet Download Page 5

Solid State Relays with Failure Detection Function

 

G3PC

J-63

SSR

Dimensions

G3PC-220B-VD

Accessories (Order Separately)

114.4

84.2

13.5

68

90±

0.2

80

8.5x3

90

±

0.3

13±

0.3

Note

  The above diagram is

for when the terminal
cover is open.

Mounting Holes

Note

  The above diagram is

for when the terminal
cover is closed.

4.6x5.6 elliptic hole

130 max.

1

100 max.

22.5 max.

Terminal cover

Tow, 4.6 dia.

Three, 4.5 dia. or M4

4.5

15 25 10 25

25

25

10

1,000 (500)

7.3

±

0.15

35

±

0.3

27

±

0.15

(see note)

15 (5) 

1,000 (500) 

35±

0.3

27 24

29.2

1.5

1

16

4.5

25

25

10

15

1,000

25

25 15

10

1,000 (500)

(see note)

(see note)

Note

  Values in parentheses indicate dimensions for the

PFP-50N.

Mounting Tracks

PFP-100N, PFP-50N

PFP-100N2

1,000 (500) 
(see note)

Summary of Contents for G3PC

Page 1: ...a heat sink In addition to screw mounting DIN track mounting is also possible Certified by EC UL and CSA Model Number Structure Model Number Legend 1 Basic Model Name G3PC SSR with Failure Detection F...

Page 2: ...N open collector Operate time 1 2 of load power source cycle 1 ms max Release time 1 2 of load power source cycle 1 ms max Main circuit Output ON voltage drop 1 6 V rms max OFF leakage current 10 mA m...

Page 3: ...00 150 200 250 The figure will be less than 1 2 the rated value for repetitive input One Cycle Surge Current Non repetitive Load Current vs Ambient Temperature Input Voltage vs Input Current Input Vol...

Page 4: ...on Note 1 With 3 phase connection so that the power supply voltage is applied between the G3PC s terminals 1 L1 and 3 connect the desired phase to terminal 3 2 Above mentioned products are 200V only T...

Page 5: ...he above diagram is for when the terminal cover is closed 4 6x5 6 elliptic hole 130 max 1 100 max 22 5 max Terminal cover Tow 4 6 dia Three 4 5 dia or M4 4 5 15 25 10 25 25 25 10 1 000 500 7 3 0 15 35...

Page 6: ...3 With inductive loads relay coil etc connect back current prevention diodes to both sides of the load Terminal name Terminal number Screw size Main circuit terminals output 1 L1 2 T1 M4 Detection pow...

Page 7: ...te Use the G3PC at a load current of 80 of the rated load current when it is mounted side by side Wiring When using crimp terminals observe the terminal clearances shown below Make sure that all lead...

Page 8: ...3PC In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert...