Ordering Information

List of Models

Note: 1. Product is labelled “250 VAC”.

2. Product is labelled “50 VDC”.

3. When ordering, specify the rated input voltage.

Accessories (Order Separately)

Connecting Sockets

Refer to page 297 for details.

Specifications

Ratings (at an Ambient Temperature of 25

°

C)

Input

Isolation

Zero cross 

function

Indicator

Rated output load 

Rated input voltage

Model

Photocoupler

Yes

Yes

3 A at 100 to 240 VAC (See note 1.) 

5 to 24 VDC

G3F-203SN-VD

2 A at 100 to 240 VAC (See note 1.) 

100/110 VAC

G3F-202SN-VD

200/220 VAC

Phototriac coupler

No

3 A at 100 to 240 VAC (See note 1.) 

5 VDC

G3F-203SLN-VD

12 VDC

24 VDC

Photocoupler

3 A at 4 to 48 VDC (See note 2.) 

5 to 24 VDC

G3FD-X03SN-VD

2 A at 5 to 110 VDC 

100/110 VAC

G3FD-102SN-VD

200/220 VAC

5 to 24 VDC

Photocoupler

Yes

No

3 A at 100 to 240 VAC (See note 1.) 

4 to 24 VDC

G3F-203S-VD

Phototriac coupler

No

5 VDC

G3F-203SL-VD

12 VDC

24 VDC

Photocoupler

3 A at 4 to 48 VDC (See note 2.) 

4 to 24 VDC

G3FD-X03S-VD

2 A at 5 to 110 VDC 

G3FD-102S-VD

Item

PYF08A-E

PY08

PY08-02

PY08QN(2)

Connecting

Front connecting

Back connecting

Mounting method/
Terminal type

Track mounted/
screw terminals

Solder terminals

PCB terminals

Wrapping terminals

Hold-down clip

PYC-A1

PYC-P

Model

Rated voltage

Operating voltage

Impedance

Voltage level

Must operate voltage

Must release voltage

G3F-203SN-VD

5 to 24 VDC

4 to 28 VDC

15 mA max. (See note.) 4 VDC max.

1 VDC min.

G3F-202SN-VD

100/110 VAC

75 to 125 VAC

41 k

Ω±

20%

75 VAC max.

20 VAC min.

200/220 VAC

150 to 250 VAC

72 k

Ω±

20%

150 VAC max.

40 VAC min.

Summary of Contents for G3F

Page 1: ...Solid State Relay 2 Rated Load Power Supply Voltage 2 200 VAC 3 Rated Load Current 02 2 A 03 3 A 4 Terminal Type S Plug in terminals 5 Zero Cross Function Blank Equipped with zero cross functions L Not equipped with zero cross function 6 Operation Indicator Blank Not equipped with operation indicator N Equipped with operation indicator 7 Certification VD Certified by UL CSA and VDE 1 Basic Model N...

Page 2: ... 48 VDC See note 2 5 to 24 VDC G3FD X03SN VD 2 A at 5 to 110 VDC 100 110 VAC G3FD 102SN VD 200 220 VAC 5 to 24 VDC Photocoupler Yes No 3 A at 100 to 240 VAC See note 1 4 to 24 VDC G3F 203S VD Phototriac coupler No 5 VDC G3F 203SL VD 12 VDC 24 VDC Photocoupler 3 A at 4 to 48 VDC See note 2 4 to 24 VDC G3FD X03S VD 2 A at 5 to 110 VDC G3FD 102S VD Item PYF08A E PY08 PY08 02 PY08QN 2 Connecting Front...

Page 3: ... min G3F 203SL VD 5 VDC 4 to 6 VDC 390 Ω 20 4 VDC max 12 VDC 9 6 to 14 4 VDC 900 Ω 20 9 6 VDC max 24 VDC 19 2 to 28 8 VDC 2 kΩ 20 19 2 VDC max G3FD X03S VD 4 to 24 VDC 3 to 28 VDC 1 5 kΩ 20 10 3 VDC max G3FD 102S VD Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage Model Rated load voltage Applicable load Load voltage range Load current Inrush ...

Page 4: ...ms max AC input 2 5 ms max Output ON voltage drop 1 6 V RMS max 1 5 V max Leakage current 5 mA max at 100 VAC 10 mA max at 200 VAC 2 5 mA max at 100 VAC 5 mA max at 200 VAC 5 mA max at 50 VDC 0 1 mA max at 100 VDC 0 1 mA max at 100 VDC Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min 1 500 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 ...

Page 5: ...G3F 202SN VD G3FD 102SN VD 102S VD 20 10 Non repetitive Keep the inrush current to half the rated value if it occurs repetitively G3FD X03SN VD X03S VD G3FD 102SN VD 102S VD Inrush current A Peak Energized time ms Inrush current A Peak Energized time ms Inrush current A Peak Energized time ms G3F 203SN VD 203S VD 202SN VD 203SLN VD 203SL VD 1 5 9 13 4 8 12 14 Load Input Load Input voltage 28 max 2...

Page 6: ...unction or undesirable effect on product performance Connection The SSR for DC switching use can connect to a load regardless of the polarity of the positive and negative output terminals Close Mounting of Multiple Relays If multiple Relays are mounted side by side be aware that the outer wall of each SSR works as a heat sink The SSR casing serves to dissipate heat Install the Relays so that they ...