150
Controlling/Outputting through Serial Communication (Non-procedure)
FZ3 User's Manual
5.
Tap [Transfer].
Contents of "String" are displayed on the window. Check that there are no problems.
ON
Description
[Send]
Character strings sent from external devices are displayed.
[Receive]
Character strings received from external devices are displayed.
6.
Tap [OK].
The Serial window closes.
Command Format (Non-procedure)
This section explains the format of commands used in the non-procedure method.
When Ethernet is used
For Ethernet connections, delimiters are not required at the end of commands.
As with scene No. acquisition commands, when acquisition data and an OK response exist next to each
other, a space (0x20) is inserted between the acquisition data and the OK response and this information
is grouped and sent as one packet.
Reference:
Command List (Non-procedure) (p.151)
Input format example (When using DISPCOND to acquire the display status
)
<Command format>
<Response format>
Important
●
With Data Output (when Ethernet output is set), up to 128 units can be registered. Note, however, that not all
data may be received depending on the network environment being used, PC performance, and the software for
receiving data.
When serial interface (RS-232C/422 connection) is used
Communication specifications are performed according to the settings in Reference:
Communication Specifications (RS-232C/422 - Non-procedure) (p.147)
Acesst 1.0 6251194