background image

Model

 

FZ-DU

USB Switcher for FZ Series

Please observe the following content.

·Do not use it in locations subject to explpsove or 

flammable gases.

·Do not attempt to disassemble, repair, or modify the 

Product.

·Do not impose voltage exceeding the rated voltage.

·When supplying power to the Sensor, make sure that the 

polarity of the power is correct, and do not connect to an 

AC power supply.

·When disposing of the USB Switcher ;treat it as 

industrial

Do not install the USB Switcher in the following 

locations.

·Locations subject to direct sunlight.

·Locations where the relative humidity exceeds the range 

of 35% to 85%.

·Locations subject to corrosive or flammable gases.

·Locations subject to direct vibration or shock.

·Locations subject to strong electromagnetic or electrical 

fields.

·If you notice any abnormality in the USB Switcher, stop 

using it immediately, turn OFF the power supply, and 

contact your OMRON sales representative.

·Regulations and Standards

 This product is compliant with the standards below:

   EN Standards(European Standards), EN61326-1

   Electromagnetic environment : Industrial   

   electromagnetic environment

   (EN/IEC 61326-1 Table 2)

Also, the following condition is applied to the immunity 

test of this product.

   : If the level of disturbance of the video is that with

    characters on the monitor are readable, the test is pass.

Observe the following precautions to prevent the product 

from malfunctioning, becoming inoperable, or the 

performance and/or the device from being adversely 

affected:

·Ambient temperature outside the rating

·Rapid temperature fluctuations (causing condensation)

·Relative humidity outside the range of 35 to 85%

·Presence of corrosive or flammable gases

·Presence of dust, salt, or iron particles

·Direct vibration or shock

·Direct sunlight

·Water, oil, or chemical fumes or spray

·Strong magnetic or electric field

·Please do not install it on the equipment with a high 

calorific value.

·Please adjust the ambient temperature of the 

specification to 50

 or less.

·Please never exceed 50

 by setting up the compulsion 

fan and the air conditioner when the ambient 

temperature of the specification is near 50

.

Please do the electrification prevention with a list strap.

Power supply display LED

It lights to green in power supply ON.

Channel display LED

LED of the selected channel lights to green.

Channel switch button

The switch of the channel is possible.

Mode switch

It is a switch that changes the operation mode.

USB input device connection connector

The USB mouse are connected.(The power supply 

capacity is 300mA or less.)

*It is not likely to be able to connect it according to 

USB mouse's kind etc.

For monitor input

The monitor cable is connected. It is possible to 

connect it up to four.

Applicable cable: 15 Pin HD D-Sub Male/Female 

#4-40Screw cable(Both sides)

For monitor output

FZ-VM is connected. The monitor screen of the 

controller who has been selected is output.

Terminal stand

When switching from the external instrument, it uses 

it. Please set the cover of the attachment.

For USB output

Four outputs or less to the FZ controller can be 

connected.

Applicable cable: USB Type-A Male/Male cable

PRECAUTIONS FOR CORRECT USE

PRECAUTIONS ON SAFETY

PRECAUTIONS FOR SAFE USE

About the installation

System configuration

External input

When you touch the terminal and

the connector area

The screw of the terminal stand uses M3. Please use the 

pressure terminal that fits the screw of M3. 

Tightening torque:0.5 to 0.6N·m

Wiring to power supply terminal

Name of each part

·Please do not install it in the board where the 

high-pressure installation is set up.

·Please separate from the power line by 200mm or more.

Noise immunity

Please turn off power when you detach the cable.
·Mounting

Please insert it straight with the part of the resin.

·Detaching

Please pull it out straight.

About detaching the cable

This unit is an option equipment only for the FZ series to 

switch by using one USB input equipment (mouse etc.) 

and one monitor and to operate two or more controllers 

(4 or less). 

Application

Specifications

About installation features

Orientation of Product

Dimensions

(1)

General specifications

(2)Performance specifications

*It doesn't correspond to DDC of the monitor.

*The power supply capacity is 300mA or less.

*Please leave space about 500ms or more about the 

channel switch.

*It is not likely to be able to connect it according to USB 

mouse's kind etc.

(3)Accessories

Instruction sheet(this sheet)
Ferrite core···2

Item

Specification

Power supply voltage
Current consumption
Insulation resistance
Dielectric strength
Leakage current
Vibration resistance

Ambient temperature
Ambient humidity

Storage temperature
Ambient environment
Degree of protection
Environmental condition

Materials
Weight

USB input interface
USB output interface
USB input interface
USB output interface
Channel switch

TypeA 1ch
TypeA 4ch
4ch(Analog RGB video)
1ch(Analog RGB video)
Channel switch button or
external signal

DC20.4 to 26.4V
MAX:200mA
20M

Ω

min. at 500V DC

1000V AC. 50/60 Hz for 1 min
1mA or less
10 to 150Hz: half-amplitude: 0.1mm
10 times each in X, Y, and Z directions for 8 min
0 to 50

Operation and storage: 35 to 85 %
(with no icing nor condensation)
-5 to +55

No corrosive gases
IP20
The indoor use
The high degree : up to 2000m.
IEC664 Pollution extent 2
Case:ABS/PC
Approx:500g

Control panel

Fan

200mm or more

200mm or more

IN0 IN1

COM IN

24VDC

+

-

CH0

POWER

MANUAL

USB INPUT

REMOTE

CH1

CH2

CH3

Mode switch

·MANUAL

The switch of the channel is 

possible by a channel switch 

button.

·REMOTE

The switch of the channel is 

possible by an external input.

USB interface

The monitor screen is 

output.

Monitor cable

USB cable

VIDEO IN No.0 

No.0 

No.3 

IN0 IN1

COM IN

24VDC

+

-

No.2 

No.1 

VIDEO OUT

VIDEO IN No.1 

USB OUT

VIDEO IN No.2 

VIDEO IN No.3 

Controller

No.0

FZ-VM

FZ-M08

Controller

No.1

Controller

No.2

Controller

No.3

Terminal stand input

External instrument

The channel can be 

switched as a 

programmable controller 

etc.

Power supply input

DC24V is input.

External

signal

IN0
IN1

Channel

No.0

OFF
OFF

Channel

No.1

ON

OFF

Channel

No.2

OFF

ON

Channel

No.3

ON
ON

Relation between switch signal and channel.

Circuit 

COM IN

Input terminal

(2)Input specification

Signal

Function

External switch

Common

IN0
IN1
COM IN

Please do the twist to the electric wire to avoid the 

inductive noise.

*COM IN Voltage:24V

Please install an accessory ferrite core on the power 

supply line. The installation position is a place separated 

from the FZ-DU side terminal by approx 10mm. 

Please install an accessory ferrite core in the mouse. The 

installation position is a place separated from the FZ-DU 

side connector by approx 10mm. 

+

IN0 IN1

COM IN

24VDC

+

-

Performance

Input voltage

On current

On voltage

Off current

Off voltage

DC12 to 24V±10

2 to 15mA

2V or less

0.1mA or less

10V or more

150

106

3.5

50

(2)

122.2

34

8

25

10

18

73

12

(9)

34

50

8

25

10

(UNIT:mm)

(mounting screw hole)

4-M3 DEPTH3

(mounting screw hole)

4-M3 DEPTH3

It is possible to select it 

with a front channel 

switch button.

It is possible to select it by 

an external input. It is not 

possible to switch with a 

front channel switch button.

MANUAL

Channel switch

Console operation

REMOTE

(1)Front panel

(2)Back panel

It operates it with the 

equipment connected 

with the USB input.

VIDEO IN No.0 

No.0 

No.3 

IN0 IN1

COM IN

24VDC

+

-

No.2 

No.1 

VIDEO OUT

VIDEO IN No.1 

USB OUT

VIDEO IN No.2 

VIDEO IN No.3 

CH0

POWER

MANUAL

USB INPUT

REMOTE

CH1

CH2

CH3

Maker

Fork type
Round type

JST
JST

V1.25-N3A

0.3 to 1.65mm

2

V1.25-MS3

Model

Size of recommended

electric wire

Recommended parts

Ferrite core

Ferrite core

USB interface

Approx 10mm

Approx 10mm

USB input device
connection connector

Terminal stand

Please roll the cable 

once in the ferrite core.

Please roll the cable 

once in the ferrite core.

USB INPUT

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

TRACEABILITY INFORMATION:

Importer  in EU :

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

© OMRON Corporation  

2010

  All Rights Reserved.

                                                               

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet 

primarily describes precautions required in installing and 

operating the product.

Before operating the product, read the sheet thoroughly to 

acquire sufficient knowledge of the product. For your 

convenience, keep the sheet at your disposal.

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 

codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 

limitations of use which apply to the Product. This information by itself is not 

sufficient for a complete determination of the suitability of the Product in 

combination with the end product, machine, system, or other application or 

use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

Oct, 2014

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.

Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Use only the same orientation as floor mounting for 

installation of the product. Do not use any other 

orientation for installation of the product.

Reviews: