Model
FZ-DU
USB Switcher for FZ Series
Please observe the following content.
·Do not use it in locations subject to explpsove or
flammable gases.
·Do not attempt to disassemble, repair, or modify the
Product.
·Do not impose voltage exceeding the rated voltage.
·When supplying power to the Sensor, make sure that the
polarity of the power is correct, and do not connect to an
AC power supply.
·When disposing of the USB Switcher ;treat it as
industrial
Do not install the USB Switcher in the following
locations.
·Locations subject to direct sunlight.
·Locations where the relative humidity exceeds the range
of 35% to 85%.
·Locations subject to corrosive or flammable gases.
·Locations subject to direct vibration or shock.
·Locations subject to strong electromagnetic or electrical
fields.
·If you notice any abnormality in the USB Switcher, stop
using it immediately, turn OFF the power supply, and
contact your OMRON sales representative.
·Regulations and Standards
This product is compliant with the standards below:
EN Standards(European Standards), EN61326-1
Electromagnetic environment : Industrial
electromagnetic environment
(EN/IEC 61326-1 Table 2)
Also, the following condition is applied to the immunity
test of this product.
: If the level of disturbance of the video is that with
characters on the monitor are readable, the test is pass.
Observe the following precautions to prevent the product
from malfunctioning, becoming inoperable, or the
performance and/or the device from being adversely
affected:
·Ambient temperature outside the rating
·Rapid temperature fluctuations (causing condensation)
·Relative humidity outside the range of 35 to 85%
·Presence of corrosive or flammable gases
·Presence of dust, salt, or iron particles
·Direct vibration or shock
·Direct sunlight
·Water, oil, or chemical fumes or spray
·Strong magnetic or electric field
·Please do not install it on the equipment with a high
calorific value.
·Please adjust the ambient temperature of the
specification to 50
℃
or less.
·Please never exceed 50
℃
by setting up the compulsion
fan and the air conditioner when the ambient
temperature of the specification is near 50
℃
.
Please do the electrification prevention with a list strap.
①
Power supply display LED
It lights to green in power supply ON.
②
Channel display LED
LED of the selected channel lights to green.
③
Channel switch button
The switch of the channel is possible.
④
Mode switch
It is a switch that changes the operation mode.
⑤
USB input device connection connector
The USB mouse are connected.(The power supply
capacity is 300mA or less.)
*It is not likely to be able to connect it according to
USB mouse's kind etc.
①
For monitor input
The monitor cable is connected. It is possible to
connect it up to four.
Applicable cable: 15 Pin HD D-Sub Male/Female
:
#4-40Screw cable(Both sides)
②
For monitor output
FZ-VM is connected. The monitor screen of the
controller who has been selected is output.
③
Terminal stand
When switching from the external instrument, it uses
it. Please set the cover of the attachment.
④
For USB output
Four outputs or less to the FZ controller can be
connected.
Applicable cable: USB Type-A Male/Male cable
PRECAUTIONS FOR CORRECT USE
PRECAUTIONS ON SAFETY
PRECAUTIONS FOR SAFE USE
■
About the installation
■
System configuration
■
External input
■
When you touch the terminal and
the connector area
The screw of the terminal stand uses M3. Please use the
pressure terminal that fits the screw of M3.
Tightening torque:0.5 to 0.6N·m
■
Wiring to power supply terminal
■
Name of each part
·Please do not install it in the board where the
high-pressure installation is set up.
·Please separate from the power line by 200mm or more.
■
Noise immunity
Please turn off power when you detach the cable.
·Mounting
Please insert it straight with the part of the resin.
·Detaching
Please pull it out straight.
■
About detaching the cable
This unit is an option equipment only for the FZ series to
switch by using one USB input equipment (mouse etc.)
and one monitor and to operate two or more controllers
(4 or less).
■
Application
■
Specifications
■
About installation features
■
Orientation of Product
■
Dimensions
(1)
General specifications
(2)Performance specifications
*It doesn't correspond to DDC of the monitor.
*The power supply capacity is 300mA or less.
*Please leave space about 500ms or more about the
channel switch.
*It is not likely to be able to connect it according to USB
mouse's kind etc.
(3)Accessories
Instruction sheet(this sheet)
Ferrite core···2
Item
Specification
Power supply voltage
Current consumption
Insulation resistance
Dielectric strength
Leakage current
Vibration resistance
Ambient temperature
Ambient humidity
Storage temperature
Ambient environment
Degree of protection
Environmental condition
Materials
Weight
USB input interface
USB output interface
USB input interface
USB output interface
Channel switch
TypeA 1ch
TypeA 4ch
4ch(Analog RGB video)
1ch(Analog RGB video)
Channel switch button or
external signal
DC20.4 to 26.4V
MAX:200mA
20M
Ω
min. at 500V DC
1000V AC. 50/60 Hz for 1 min
1mA or less
10 to 150Hz: half-amplitude: 0.1mm
10 times each in X, Y, and Z directions for 8 min
0 to 50
℃
Operation and storage: 35 to 85 %
(with no icing nor condensation)
-5 to +55
℃
No corrosive gases
IP20
The indoor use
The high degree : up to 2000m.
IEC664 Pollution extent 2
Case:ABS/PC
Approx:500g
Control panel
Fan
200mm or more
200mm or more
IN0 IN1
COM IN
24VDC
+
-
CH0
POWER
MANUAL
USB INPUT
REMOTE
CH1
CH2
CH3
■
Mode switch
·MANUAL
The switch of the channel is
possible by a channel switch
button.
·REMOTE
The switch of the channel is
possible by an external input.
USB interface
The monitor screen is
output.
Monitor cable
USB cable
VIDEO IN No.0
No.0
No.3
IN0 IN1
COM IN
24VDC
+
-
No.2
No.1
VIDEO OUT
VIDEO IN No.1
USB OUT
VIDEO IN No.2
VIDEO IN No.3
Controller
No.0
FZ-VM
FZ-M08
Controller
No.1
Controller
No.2
Controller
No.3
■
Terminal stand input
・
External instrument
The channel can be
switched as a
programmable controller
etc.
・
Power supply input
DC24V is input.
External
signal
IN0
IN1
Channel
No.0
OFF
OFF
Channel
No.1
ON
OFF
Channel
No.2
OFF
ON
Channel
No.3
ON
ON
Relation between switch signal and channel.
Circuit
COM IN
Input terminal
(2)Input specification
Signal
Function
External switch
Common
IN0
IN1
COM IN
Please do the twist to the electric wire to avoid the
inductive noise.
*COM IN Voltage:24V
Please install an accessory ferrite core on the power
supply line. The installation position is a place separated
from the FZ-DU side terminal by approx 10mm.
Please install an accessory ferrite core in the mouse. The
installation position is a place separated from the FZ-DU
side connector by approx 10mm.
+
IN0 IN1
COM IN
24VDC
+
-
Performance
Input voltage
On current
On voltage
Off current
Off voltage
DC12 to 24V±10
%
2 to 15mA
2V or less
0.1mA or less
10V or more
150
106
3.5
50
(2)
122.2
34
8
25
10
18
73
12
(9)
34
50
8
25
10
(UNIT:mm)
(mounting screw hole)
4-M3 DEPTH3
(mounting screw hole)
4-M3 DEPTH3
It is possible to select it
with a front channel
switch button.
It is possible to select it by
an external input. It is not
possible to switch with a
front channel switch button.
MANUAL
Channel switch
Console operation
REMOTE
(1)Front panel
(2)Back panel
It operates it with the
equipment connected
with the USB input.
VIDEO IN No.0
No.0
No.3
IN0 IN1
COM IN
24VDC
+
-
No.2
No.1
VIDEO OUT
VIDEO IN No.1
USB OUT
VIDEO IN No.2
VIDEO IN No.3
①
③
②
④
①
②
③
CH0
POWER
MANUAL
USB INPUT
REMOTE
CH1
CH2
CH3
④
⑤
Maker
Fork type
Round type
JST
JST
V1.25-N3A
0.3 to 1.65mm
2
V1.25-MS3
Model
Size of recommended
electric wire
Recommended parts
Ferrite core
Ferrite core
USB interface
Approx 10mm
Approx 10mm
USB input device
connection connector
Terminal stand
Please roll the cable
once in the ferrite core.
Please roll the cable
once in the ferrite core.
USB INPUT
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU :
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
© OMRON Corporation
2010
All Rights Reserved.
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet
primarily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your
convenience, keep the sheet at your disposal.
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
Use only the same orientation as floor mounting for
installation of the product. Do not use any other
orientation for installation of the product.