Inspecting with the Shape Search II Inspection Item
258
FQ2-S/CH User’s Manual
Measurement Data That Can Be Logged
The following values can be logged as measurement data.
* When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data
Errors
Errors in Teaching
A teaching error message will appear if the contrast of the image within the model registration region is too low.
Select a region with a larger contrast between light and dark areas compared to the region that was registered
as the model and re-register it as the model.
Parameter
Range of value
Description
Judgement
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the measurement judgment results.
Correlation
0 to 100
This is the measured correlation.
Position X
-99999.9999 to 99999.9999
This is the measurement position X.
Position Y
-99999.9999 to 99999.99999
This is the measurement position Y.
Angle
−
180 to 180
This is the measurement angle.
Count
0 to 32
This is the number of models found.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......