background image

FJ-35

FJ-35

-10

8.5mm max.

8.5mm max.

This product contains a lithium battery for which the following notice applies :Perchlorate Material - special 

handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate

Camera cable

FZ-VS3 (2 m, 3m, 5 m, 10 m)

Bend resistant camera cable

FZ-VSB3 (2 m, 3m, 5 m, 10 m)

Right-angle camera cable

FZ-VSL3 (2 m, 3m, 5 m, 10 m)

Bend resistant

Right-angle camera cable

FZ-VSLB3 (2 m, 3m, 5 m, 10 m)

Long-distance camera cable

FZ-VS4 (15m)

Long-distance Right-angle

camera cable

FZ-VSL4 (15m)

Standalone camera

FZ-SC/FZ-S/

FZ-SC2M/FZ-S2M/

FZ-SC5M2/FZ-S5M2/

FZ-SFC/FZ-SF/

FZ-SPC/FZ-SP/

FZ-SHC/FZ-SH/
Intelligent compact camera

FZ-SQ010F/FZ-SQ050F/

FZ-SQ100F/FZ-SQ100N

*

Camera 2ch type

FJ-350
FJ-355

Camera 4ch type

FJ-350-10
FJ-355-10

Controller

Camera cable

*

LCD monitor

Monitor cable

*

*

Detects workpieces as images.

Camera

USB memory

FZ-MEM2G/FZ-MEM8G

Mouse, track ball

(Commercially available USB devices)

Recommended Model

By OMRON Corporation

S8VS-12024(FJ-35

)

S8VS-18024(FJ-35

-10)

*

Power Supply

Peripheral Device

Input Device

*

Power Supply Wiring

24VDC

+ 

− 

FJ-350/FJ-355/FJ-350-10/FJ-355-10

 Lit while power is ON.

 Lit or turned off according  to the layout under the display.

 Lit when an error has occurred.

 Connect the controller to external devices such as a sync sensor and PLC.

 Connect cameras.

 Connect a DC power supply. Wire the power supply unit independently of other devices. After wiring, 

replace the terminal cover.

• The following items can be connected to USB ports.  • Commercially available track ball, mause and USB memory.
• Never insert/remove USB devices during measurement. Doing so may affect measurement time.

 Connect a monitor.

 Connect an external device such as a personal computer or PLC.

 Connect an external device such as a personal computer or PLC.

⑩ 

Connect a mouse and USB memory, etc. Two USB ports are provided and any of them can be used. 

However, when USB memory is connected with both ports, doing so may cause the USB memories to 
come into contact, resulting in malfunction or damage.

POWER LED

USB connector

Monitor connector (analog RGB)

Ethernet connector

Camera connector

Only Camera 4ch type

(FJ-35

-10)

RS-232C connector

Power terminal

I/O connector

(control lines, data lines)

RUN LED

ERROR LED

Model

2011

PC Vision  System

Meanings of Signal Words

Meanings of Alert Symbols

Alert statements in this Manual

Precautions for Correct Use

Precautions for Safe Use

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

Kyoto 600-8530 JAPAN

TRACEABILITY INFORMATION:

Importer  in EU :

  Omron Europe B.V.

Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

WARNING

CAUTION

The following signal words are used in this manual.

The following alert symbols are used in this manual.

The following alert statements apply to the products in this 

manual. Each alert statement also appears at the locations 

needed in this manual to attract your attention.

This product must be used according to the 

instruction manual. Failure to observe this may 

result in impairment of functions and 

performance of the product.
This product is not designed or rated for 

ensuring safety of persons. Do not use it for 

such purposes.
Never connect the AC power supply with this

product. When the AC power supply is

connected, it causes the electric shock and a fire.
A lithium battery is built into the Controller and 

may occasionally combust, explode, or burn if 

not treated properly. Dispose of the Controller as 

industrial waste, and never disassemble, apply 

pressure that would deform, heat to 100

 or 

higher, or incinerate the Controller.
Since camera that can be connected with this 

product emits a visible light that may have an 

adverse affect on the eyes, do not stare directly 

into the light emitted from the LED. If a specular 

object is used, take care not to allow reflected 

light enter your eyes.

Danger of burns. Do not touch the case while the 

LED is ON or just after power is turned OFF, 

since it remains extremely hot.

• Use a DC power supply with safety measures against 

high-voltage spikes(safety extra low-voltage circuits on 

the secondary side).

• Do the following confirmations again before turning on 

the power supply. 

 - Is the voltage of the power supply correct? (24VDC)

 - Is not the load of the output signal short-circuited?

 - Is the load current of the output signal appropriate?

 - Is not the mistake found in wiring?

●Ground

• 

The controller power circuit is not insulated from its 

internal circuit.

• 

Be sure to use a spacer when connecting a camera to 

the controller. As the housing of the camera is the SG 

(0V), it can cause short-circuiting between the SG (0V) 

and the FG if a spacer is not used.

• It is short-circuited with FG of the customer device 

when installing it directly because the case of the 

controller is connected with SG(0V).

• Do not ground the 24VDC power supply's positive 

terminal. If the positive terminal is grounded, it causes 

the electric shock when you touch the SG(0V) such as 

case of the controller or the camera.

Other

• Use only the camera and cables designed specifically for 

the product. Failure to observe this result in malfunction 

or damage of the product.

• Always turn OFF the Controller's power before connecting 

or disconnecting a camera or cable.

• Do not attempt to dismantle,repair,or modify the product.

• Should you notice any abnormalities,immediately stop 

use,turn OFF the power supply,and contact your OMRON 

representative.

• Do not touch fluorescent or halogen lights while the power 

is ON or immediately after the power is turned OFF.

• Dispose of this product as industrial waste.

Regulations and Standards

The Controller complies with the following standards.

EN Standards(European Standards), EN61326-1

(Electromagnetic environment : Industrial 

electromagnetic environment 

(EN/IEC  61326-1 Table 2)

Also, the following condition is applied to the 

immunity test of this product.

  

: If the level of disturbance of the video is that with 

    

characters on the monitor are readable, the test is    

         pass.

Regulation of KC marking

A급 기기(업무용 방송통신기자재)

이 기기는 업무용(A급) 전자파적합기기로서 판매자

또는 사용자는 이 점을 주의하시기 바라며,가정외의

지역에서 사용하는 것을 목적으로 합니다.

• Keep the power supply wires as short as possible

(Max.10m).

Installation and Storage Sites

Install and store the product in a location that meets the 

following conditions:

• Surrounding temperature of 0 to 50

 (-20 to +65

 in 

storage)

• No rapid changes in temperature (place where dew does 

not form)

• Relative humidity of between 35 to 85 %

• No presence of corrosive or flammable gases

• Place free of dust, salts and iron particles

• Place free of vibration and shock

• Place out of direct sunlight

• Place where it will not come into contact with water, oils 

or chemicals

Orientation of Product

To improve heat dissipation, install the product in the

following orientation only.

Ambient Temperature

• Maintain a minimum clearance of 50 mm above the 

controller to improve air circulation. A minimum clearance 

of 25 mm between other devices must also be maintained 

on the right, left and back sidesof product.

• Do not install the product immediately above significant 

heat sources, such as heaters, transformers, or 

large-capacity resistors.

• Do not let the ambient temperature exceed 50

(122°F).

• Provide a forced-air fan cooling or air conditioning if the 

ambient temperature is near 50

(122°F) so that the

ambient temperature never exceeds 50

(122°F).

Noise Resistance

• Do not install the product in a cabinet containing 

high-voltage equipment.

• Do not install the product within 200 mm of power cables.

Component Installation and Handling

• Touching Signal Lines

To prevent damage from static electricity, use a wrist 

strap or another device for preventing electrostatic 

discharges when touching terminals or signal lines in 

connectors.

• Handling a USB Memory

To remove a USB memory, make sure that data is not 

being read or written to it. The LED on the USB memory 

flashes while data is being read or written, so make sure 

that it is lit steadily before removing the memory.

• Turning OFF the Power

Do not turn OFF the power while a message is being 

displayed indicating that processing is being performed. 

Data in memory will be corrupted, and the product may 

not operate correctly the next time it is started.

• Using the RESET Signal

Do not use the RESET input immediately after power is 

turned ON. When using the RESET input to synchronize 

startup timing,wait at least 15 second after the 

Controller’ s power supply is turned ON before turning 

ON the RESET signal.

Maintenance

Turn OFF the power and take safety precautions before 

conducting inspections. Electrical shock can result from 

attempting safety inspections with the power turned ON.

• Clean the lens with a lens-cleaning cloth or air brush.

• Lightly wipe off dirt with a soft cloth.

• Dirt on the CCD must be removed using an air brush.

• Do not use thinners or benzene.

Communication with High-order Device

After confirming that this product is started up, 

communicate with the high-order device. When this 

product has started up, an indefinite signal may be output 

from the high-order interface. To avoid this problem, clear 

the receiving buffer of your device at initial operations.

Installation Environment

• Do not use the product in areas where flammable or 

explosive gases are present.

• Install the product so that air can flow freely through its 

cooling vents.

• Do not install the product close to high-voltage devices 

and power devices in order to secure the safety of 

operation and maintenance.

• Make sure to tighten all installation screws securely.

Power Supply and Wiring

• Make sure to use the product with the power supply 

voltage specified by this manual.

• Use a power supply cable and crimp terminals of the 

specified size. Do not simply connect the twisted ends of 

the wires directly to the terminal block.

-Applicable wire size:1.31 to 2.63mm

2

-Terminal screw:M4

-Crimp terminals

Indicates a potentially hazardous 

situation which, if not avoided, will 

result in minor or moderate injury, or 

may result in serious injury or death. 

Additionally there may be significant 

property damage.

WARNING

Indicates a potentially hazardous 

situation which, if not avoided, may 

result in minor or moderate injury or in 

property damage.

Indicates general prohibitions for which there is 

no specific symbol.
Indicates the possibility of electric shock under 

specific conditions.
Indicates the possibility of explosion under 

specific conditions.

Indicates the possibility of laser radiation.

Indicates the possibility of injury by high 

temperature under specific conditions.

The Controller performs the image 

processing specified by the user settings 

and outputs the measurement results.

Use the monitor to check images and

display the condition-setting menus.

Do not install in this orientation.

CAUTION

Basic Configuration

Component Names and Functions

U.S. California Notice:

* Items indicated with an asterisk are dedicated items, and cannot be substituted.

FZ-M08 (8.4-inch)

FZ-VM (2m,5m)

© 

OMRON Corporation              All Rights Reserved.

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.

The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio 
interference, in which case the user may be required to take adequate 
measures to reduce interference.

Summary of Contents for FJ-350

Page 1: ...や大容量の抵抗など 発熱量の高い機 器の真上には取付けないでください 使用周囲温度は50 以下にしてください 使用周囲温度が50 に近い場合は 強制ファンやクーラ ーを設置して 常時50 を超えないようにしてくださ い 耐ノイズ性 高圧機器の設置されている盤内には取付けないでくださ い 動力線からは 200mm以上離してください 構成品の設置や取扱いについて 信号線に触れる 端子部分やコネクタ内部の信号線に触れる場合は 静電 気による破損を防ぐため リストストラップなどを使用 して帯電防止措置を行ってください USBメモリの取扱い USBメモリを取外す場合は データの読み 書き中でな いことを確認して取外してください データの読み 書き 中はUSBメモリ本体のLEDが点滅しますので 点灯状態 になったことを確認して取り外してください 電源を切る 処理を実行中であることを示すメッセージが画面...

Page 2: ... 入力 信号名 TRD 0 TRD 0 TRD 1 TRD 2 TRD 2 TRD 1 TRD 3 TRD 3 信号方向 入出力 入出力 入出力 入出力 入出力 入出力 入出力 入出力 メーカ オムロン 株 オムロン 株 コントローラ RS 232C ピン番号 接続する外部装置 RS CS制御はできません ケーブル長は 15m以下にしてください 操作 シリアル通信 ネットワーク通信 EtherNet IP通信 パラレル入出力 モニタI F USB I F 電源電圧 消費電流 DC24V接続時 耐ノイズ性 耐振動 耐衝撃 周囲温度範囲 周囲湿度範囲 周囲雰囲気 保護構造 ケース材質 質量 内容品 マウスなどによる操作 RS 232C準拠 Ethernet 1000BASE T 100BASE TX 10BASE T Ethernetポート使用 伝送速度 100Mbps 100BASE TX ...

Page 3: ...andards EN61326 1 Electromagnetic environment Industrial electromagnetic environment EN IEC 61326 1 Table 2 Also the following condition is applied to the immunity test of this product If the level of disturbance of the video is that with characters on the monitor are readable the test is pass Regulation of KC marking A급 기기 업무용 방송통신기자재 이 기기는 업무용 A급 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정외의 지역에서 사용...

Page 4: ...the screws on both sides of the connector Turn OFF the power supply before connecting or disconnecting a Cable Peripheral devices may be damaged if the cable is connected or disconnected with the power ON Parallel Interface Serial Interface Controller Specifications Each output signal Each output signal Each input signal Each input signal 24V 0V 24 VDC 24 VDC Load Load 100BASE TX 10BASE T 1000BASE...

Page 5: ...G 间短路 由于控制器壳与 SG 0V 连接 直接安装时 会与客户 装置的 FG 短路 24V 直流电的正极端不要接地 否则触摸诸如控制器壳或 摄像机等 SG 0V 时 会导致触电 其它事项 仅采用专为该产品设计的摄像机和电缆 否则会导致产品 功能故障或损坏产品 连接或断开摄像机或电缆前 给控制器断电 不要尝试拆卸 修理或修改该产品 发现异常时 立即停止使用 关闭电源 联系 OMRON 代 表处 通电时或刚关闭电源后 不要触摸荧光灯或卤素灯 按工业废物处理该产品 规定和标准 该控制器符合以下标准 EN standard EN61326 1 Electromagnetic environment Industrial electromagnetic environment EN IEC 61326 1 Table 2 于本产品的 imyuniti 考试 以下的条件被适用 于显示器表示 文字的...

Page 6: ...出 输入 输出 输入 输出 输入 输出 输入 输出 输入 输出 输入 输出 输入 输出 生产商 OMRON公司 OMRON公司 控制器 RS 232C 插针号 连接外部装置 不能使用RS CS控制 电缆最大长度15 m 操作 串行通信 网络通信 EtherNet IP通信 并联输入 输出 监控器接口 USB接口 电源电压 电流消耗 24V直流电源连接时 抗干扰性 抗振性 抗冲击性 周围温度范围 周围湿度范围 周围环境 保护级别 环境条件 遵照IEC61010 1 壳体材料 重量 商品内容 将接口与套接口对齐 直接压到位 然后在接口两 侧用螺丝固定 连接或断开电缆前请关闭电源 开启电源情况下连 接或断开电缆可能损坏外围装置 并联接口 串行接口 控制器规格 每个输出信号 每个输出信号 每个输入信号 每个输入信号 24V 0V 24V直流电 24V直流电 负载 负载 100BASE TX 10B...