2-13-2-2. Installation Example 1 of Standard Muting Mode (Using Two
Muting Sensors)
This is an example of two retro-reflective type photoelectric sensors used as muting sensors installed
in a cross pattern.
Use two sensors when the length L of the workpieces are not constant or are insufficient.
1.
Before a workpiece passes through
The output state of the muting sensors A1 and B1 are both OFF, and the safety function of the F3SG-
SR is enabled.
In this example where two muting sensors are used, the crossover point of the muting sensors A1 and
B1 is in the hazardous zone. This configuration prevents the Muting function from being enabled by a
person passing through the crossover point.
2.
MUTING started
When the muting sensors A1 and B1 are turned ON in this order, the F3SG-SR enters the MUTING
state. In this state, the safety function of F3SG-SR is disabled.
Workpiece
L
F3SG-SR
F3SG-SR
d1=D1
B1
Mirror
Mirror
A1
Hazardous zone
V
The crossover point of muting sensors
A1 and B1 must be located within the
hazardous zone
L: Length of workpiece
d1: Maximum distance required for the muting sensor to keep the muting function enabled
D1: Minimum distance required for the muting sensor to keep the muting function enabled
Workpiece
F3SG-SR
Hazardous zone
B1
Mirror
Mirror
A1
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...