7
F3SG-R
User’s Manual
Chapter
1
List of
Fea
ture
s
Overview and Specifications
E
1-3-3. List of Features
The F3SG-R safety light curtain family has the following features. For the F3SG-RA, some of the
features are available or configurable by the DIP Switch on the body of the safety light curtain or the
Configuration Tool (SD Manager 2) via a PC.
Setting with DIP Switch and Configuration Tool is not available for the F3SG-RE.
* The functions are upgraded in Version 1.1 of F3SG-RA.
Feature
F3SG-RA Series
F3SG-RE
Series
Page
Setting by
DIP Switch
Setting by
Configuration
Tool
Factory default setting
Scan Code Selection
X
Code A
PNP/NPN Selection
X
PNP output
External Test
X
24 V Active
Interlock
X
X
Auto Reset Mode
Pre-Reset
X
X
Disabled
External Device Monitoring(EDM)
X
X
Disabled
Auxiliary Output
X
Safety output information
(Inverted signal output:Enable)
Muting
X
Standard Muting mode
Override
X
Enabled
Fixed Blanking *
X
X
Disabled
Floating Blanking *
X
X
Disabled
Reduced Resolution
X
Disabled
Warning Zone
X
Disabled
Operating Range Selection
X
Long mode
X
Response Time Adjustment
X
Normal mode
Lamp
X
Red:Safety output information(Inverted
signal output :Enable)
Orange:Stable-state
information(Inverted signal output
:Enable, Output pattern:ON 1 time)
Green:Safety output information
Designated Beam Output
X
Disabled
Muting Statistics Data Recording *
X
Enabled
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...