![Omron F3SG-RA User Manual Download Page 141](http://html1.mh-extra.com/html/omron/f3sg-ra/f3sg-ra_user-manual_743106141.webp)
117
F3SG-R
User’s Manual
Ch
apt
e
r
3
Set
ting by Te
ac
h-in
Setting with DIP Switch
E
3-3-2. Setting Floating Blanking by Teach-in
Overview
You can teach-in the floating blanking setting by interrupting with an object to monitor by floating
blanking. The teach-in task is performed using the Push Switch.
After completion of teach-in, check that the configuration have been properly done.
Teach-In Steps
Perform the teach-in setting of floating blanking based on the following steps.
(1) Beam Adjustment
(2) DIP Switch Setting
(3) Transition to Teach-in Mode
(4) Result Check Process
(5) Restart
(1) Beam Adjustment
Adjust the beams of the emitter and receiver for synchronization.
For detailed beam adjustment steps, see
4-4-4. Beam Alignment Procedure
Misalignment during teach-in may result in an unintended setting or a failure of teach-in.
(2) DIP Switch Setting
When the power of the F3SG-RA is turned OFF, set the Blanking setting (Position 5 and 6) of the DIP
Switch as "Floating Blanking Enabled" and the DIP Switch/Configuration Tool Selection setting
(Position 8) as "DIP Switch Enabled". And then turn the power of the F3SG-RA on.
Block the target Floating Blanking zone by an object. Do not remove the object until the Step (4) is
complete.
The object must be no smaller than the object resolution.
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...