40
Chapter
4
Instal
lati
on C
o
nsider
a
tion
s
F3SG-4RA-25-02TS
User’s Manual
Wiring/Installation
4-1-3. Distance from Reflective Surfaces
Install the sensor system so that it is not affected by reflective surfaces. Failure to do so
may hinder detection, resulting in serious injury.
4-1-3-1. Type 4 ESPE
Install the sensor system at distance D or further from highly reflective surfaces such as metallic walls,
floors, ceilings, or workpieces, as shown below.
Distance between an emitter and a
receiver (operating range L)
Allowable installation distance
D
0.3 to less than 3 m
0.13 m
3 m or more
L/2 x tan5 ° = L x 0.044 m
L
D
D
L
D
5
5
Detection zone
Emitter
Receiver
Reflective ceiling
Reflective floor
Emitter
Receiver
Reflective surface