144
Chapter
2
Ma
in
te
nanc
e Info
rmat
ion
F3SG-SR/PG
User’s Manual
System Operation and Functions
• Load switching frequency reset
This function can reset the load switching frequency of the F3SG-SR/PG to zero. When the F3SG-SR/
PG is in cascade connection, the load switching frequency can be reset for each cascaded F3SG-SR/
PG segment. Use this reset function whenever you install or replace relays or contactors.
The user can make changes to the settings by the SD Manager 3.
For how to check and configure setting by SD Manager 3, refer to
4-4-3-4. Power-On Time/Load Switching Frequency
.
2-27-6. Muting Statistics Information
This function logs and visualizes conditions of the F3SG-SR/PG muting operations to help the user
adjust settings of muting input time difference. Also, its statistic calculation allows for optimal settings
with reduced test runs.
Refer to
for more information on using this function by the SD Manager 3 or SD Manager 3
Mobile APP.
2-27-7. Intelligent Tap Log
You can use the SD Manager 3 to read the maintenance information (Error Log / Accumulated power-
on time) of the Intelligent Tap to view on a PC screen. The Maintenance Information function indicates
the following information:
• Error Log
The user can view details of errors occurred in the past. The error information is recorded in the
Intelligent Tap at the time of occurrence of an error. The displayed information is useful for
troubleshooting. Up to 50 past errors can be recorded.
• Accumulated power-on time
The user can view an accumulated value of power-on time from when the Intelligent Tap is powered on
for the first time after purchase until the present. It is not possible to reset this value by the power-on
time reset function.
For how to check by SD Manager 3, refer to
Function
Initial value
Configurable value or numerical range
Load switching frequency threshold
100,000 times in 1-time increment 100,000 to 4,000,000 times in 1-time increments/
Disable
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...