4
F3SG-4RA
-25-01TS
Quick Installation Manual
5.Wiring Examples
For input/output circuit and other examples than below, refer to
User's Manual
.
5-1. EDM disabled, External Test disabled and PNP Outputs
5-2. EDM enabled, External Test 0V Inactive and NPN Outputs
24 VDC: Brown
24 VDC: Brown
External device monitoring input: Red
TEST: Black *2
Not used: Yellow
Not used: Gray
Not used: Gray
Not used: Pink
Not used: Pink
OSSD1: Black
OSSD2: White
Not used: Red
Not used: White
0 VDC: Blue
0 VDC: Blue
AUX: Yellow
Shielded wire
Shielded wire
E1
+DC24V
F39-JD
A-L
F39-JD
A-D
0V
Safety
Controller
*3 *4
IN1
IN2
Emitter
Receiver
*1. The functions are configurable with DIP Switch. Refer to
for more information.
*2. When the external test function is used, connect to 24V via the test switch (N.C. contact).
*3. Refer to
User's Manual
for more information.
*4. The safety controller and the F3SG-RA must share the power supply or be connected to the common terminal of the power supply.
[DIP Switch settings] *1
Function
Receiver
EDM Disabled (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Inactive
E1: 24VDC power supply (S8VS)
Emitter
㻷㻹㻝 㻷㻹㻞
PLC
IN
E1
+DC24V
0V
S1
㻷㻹㻝
㻷㻹㻞
Receiver
24 VDC: Brown
24 VDC: Brown
External device monitoring input: Red
TEST: Black
Not used: Yellow
Not used: Gray
Not used: Gray
Not used: Pink
Not used: Pink
OSSD1: Black
OSSD2: White
Not used: Red
Not used: White
0 VDC: Blue
0 VDC: Blue
AUX: Yellow
Shielded wire
Shielded wire
F39-JD
A-L
F39-JD
A-D
* The functions are configurable with DIP Switch. Refer to
for more information.
[DIP Switch settings] *
Function
Receiver
EDM Enabled
NPN
Emitter
External Test: 0 V Inactive
S1: External test switch(connect to 0V if a switch is not
required)
KM1, KM2: Safety relay with forcibly guided contacts
(G7SA) or magnetic contactor
E1: 24VDC power supply (S8VS)
PLC: Programmable controller (Used for monitoring -- not
related to safety system)
Mounting/Beam Alignment
Wiring
Setting with DIP Switch
Operation check