WARNING

When using multiple sets of the F3S-A

j

P, install them so that

mutual interference is not incurred by connecting them with

sync line or using a barrier.

Correct Configuration

Receiver

Emitter

Receiver

Emitter

Interference from Another F3S-A

j

j

j

j

P

Receiver

Emitter

Receiver

Emitter

Countermeasure to Prevent Interference

Receiver

Emitter

Receiver

Emitter

Barrier

J

INSTALLATION CONDITIONS

For your safety, always heed the following:

DC Power Supply Units Must Satisfy

All These Conditions

The power supply is connected to the F3S-A

j

P only and not

to other devices or equipment.

The power supply voltage is within the rating (24 VDC

±

10%).

Wiring is conducted only after confirming polarities of the

power supply.

The power supply conforms to EMC Directive (industrial
environment).

The power supply conforms to Low-voltage Directive.

The power supply uses double or reinforced insulation be-

tween the primary and secondary circuits.

The power supply automatically resets overcurrent protection

characteristics (voltage drop).

The power supply maintains an output holding time of at least

20 ms.

When using a commercially available switching regulator,
make sure FG (frame ground terminal) is connected to PE
(protective earth). Faulty operation caused by switching

noise may result if the terminal is not connected.

Use one of the following wiring configurations to reduce noise
terminal voltage to the primary side of the power supply:

Connect the 0V line to PE (protective earth).

Mount a capacitor with a minimum 47-nF capacity and
minimum 630 V voltage rating between the 0V line
and PE.

Recommended Power Supplies: S82K, S8PS, S82J or S82H
made by OMRON.

Load Must Satisfy All These Conditions

Is not shorted.

Does not use current higher than the rating.

Is double insulated to protect the load from hazardous

voltage levels when the load is a relay.

Correct Use

Failure to observe the following items may result in F3S-A

j

P

damage, deterioration, or improper operation.

Installation Environment

Do not install the F3S-A

j

P in the following environments:

Areas exposed to intense interference light such as direct
sunlight.

Areas with high-humidity where condensation is likely to
occur.

Areas exposed to corrosive gases.

Areas exposed vibration or shock levels higher than
specification provisions.

Areas exposed to contact with water.

Do not use cellular phones or transceivers near the F3S-A

j

P.

Wiring and Mounting

Be sure to turn OFF the power prior to wiring, or the
diagnostic function may prevent the F3S-A

j

P from operating.

Be sure to use shielded twisted-pair cables (cross-section at

least 0.2 mm

2

in diameter) when extending the sync line

without using an F39-JA

j

A Series Connection Cable.

Connect the shield to 0 V line.

When using resin or other connectors in place of the unit’s
metal connector, make sure the conductor path in the

connector is rated IP54 or higher.

Check signal names for all terminals and wire terminals

correctly.

When using two or more F3S-A

j

P sets, be sure to connect

a sync line and turn ON all power supplies at the same time
(within 0.5 s). Never exceed specifications for the total
number of sets and total number of the optical beams (up to

192 beams).

The F3S-A

j

P will start operating in five seconds after the

power is turned ON. Make sure that no faulty operation will

occur in the control system.

Once power is turned ON, do not turn it OFF again before the
F3S-A

j

P becomes operational (LED indicator lights).

Be sure to route F3S-A

j

P wires separated from high-poten-

tial power lines or to route through an exclusive conduit.

Make sure the emitter and receiver are facing the proper

direction.

Use the interference light search function for no longer than
8 hours from startup, or the F3S-A

j

P will switch to OFF-hold

condition (stop due to temporary failure).

Use the emitter and receiver packed with the F3S-A

j

P and

install them opposite to each other.

!

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for F3S-A082P

Page 1: ...onnect multiple units for a larger protected zone H M12 connector Ordering Information J SAFETY LIGHT CURTAINS Shape detection distance Beam spacing Minimum detectable object No of beams n Protective...

Page 2: ...F39 JA1C cable 1 pair required 7 m 23 0 ft F39 JA2C 10 m 32 8 ft F39 JA3C Series connection cable required for multiple units connected together 200 mm 7 87 in F39 JA1B J ACCESSORIES Type Description...

Page 3: ...External diagnosis input line Open or 9 to 24 V Interference light search External diagnosis input line 0 to 1 5 V Emitting ON 3 mA max short circuit current Indicator Emitter Light indicator orange...

Page 4: ...R36 mm attached cable 400 mm length Materials Case Aluminum Front cover PMMA acrylic resin Cable PVC Accessories Test rod mounting brackets top and bottom mounting brackets intermediate for the F3S A3...

Page 5: ...g Perpendicular to Center Line of Lenses Distance Y mm Distance X m F3S A482P 20 mm beam spacing Parallel to Center Line of Lenses Distance Y mm Distance X m F3S A482P 20 mm beam spacing Perpendicular...

Page 6: ...receiver circuit 1 Brown Pink Violet 1 Blue External diagnosis input 2 Brown Blue Black Output 1 White Output 2 Load 1 Load 2 3 3 Red Black Sync line 2 Main receiver circuit 2 24 V 0 V 1 Master Connec...

Page 7: ...jP carefully to ensure the machine will not malfunction due to the OFF signal Light receiving status Output transistor 55 ms max ON OFF 9 6 ms 20 ms max Stable light reception Reception Interrupted Nu...

Page 8: ...356 4 0 65 14 03 0 03 388 5 1 25 15 30 0 05 F3S A481P 470 0 5 18 50 0 02 516 4 0 75 20 33 0 03 548 5 1 35 21 60 0 05 F3S A082P 140 0 3 5 51 0 01 20 0 5 0 79 0 02 196 4 0 55 7 73 0 2 228 5 1 15 9 00 0...

Page 9: ...37 1 46 Mounting Brackets Intermediate Used with the F3S A322P F3S A402P and F3S A482P only Mounting screw for Light Curtain M6x8 U shaped intermediate bracket Attached to the mounting bracket Flat i...

Page 10: ...andard length L 3 7 and 10 m For Emitter For Receiver Series Connection Cable F39 JA1B 6 dia vinyl insulated round cable with four conductors 12 0 18 dia and four conductors 7 0 2 dia Standard length...

Page 11: ...o wire an interface to the light curtain F3S Aj j j jP Safety Light Curtain Wiring Diagram DANGER K1 K2 K3 must be captive contact type safety relays Serious injury or death may result if this type re...

Page 12: ...nc line 1 red black Sync line 1 red Sync line 1 red black Sync line 1 red Shield Sync line 2 gray Open Sync line 2 gray black Master selection input violet External diagnosis input pink Open 0 V blue...

Page 13: ...section Remove the cable cap Remove the cap unit Series Connection Cable F39 JA1B Optional Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downl...

Page 14: ...E2 Note When connecting the Series Connection Cable F39 JAjA is useful Allocation of the pins of the main body is as shown below Connector 14 9 dia 44 7 Pin no Signal name Receiver Emitter 1 0 V 0 V 2...

Page 15: ...ly by passing through the F3S AjP detection zone Incorrect Installation Dangerous machine parts can be reached without passing through the F3S AjP detection zone A worker is between the F3S AjP detec...

Page 16: ...P in the following environments Areas exposed to intense interference light such as direct sunlight Areas with high humidity where condensation is likely to occur Areas exposed to corrosive gases Area...

Page 17: ...lobal http www omron com USA http www omron com oei Canada http www omron com oci F3S Aj j j jP F3S Aj j j jP Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded f...

Reviews: