background image

4. Error Messages and Troubleshooting

4.1 Error Messages

4.2 Troubleshooting

In case of any of the below problems occur during measurement, first check that 
no other electrical device is within 30cm. If the problem persists, please refer to 
the table below. 

5. Maintenance and Storage

5.1 Maintenance

To protect your device from damage, please follow the directions below:

• Store the device and the components in a clean, safe location.
• Do not use any abrasive or volatile cleaners.
• Do not wash the device and any components or immerse them in water.
• Do not use gasoline, thinners or similar solvents to clean the device.

• Use a soft dry cloth, or a soft cloth moistened with neutral soap to clean on 

the monitor and the arm cuff, and then wipe it with a dry cloth.

• Changes or modification not approved by the manufacturer will void the 

user warranty. Do not disassemble or attempt to repair the device or 
components. 

Calibration and Service

• The accuracy of this blood pressure monitor has been carefully tested and 

is designed for a long service life.

• It is generally recommended to have the device inspected every 2 years to 

ensure correct functioning and accuracy. Please consult your OMRON 
retail outlet or distributor. 

5.2 Storage

Do not store the device in the following situations:

•  If the device is wet.
•  Locations exposed to extreme temperatures, humidity, direct sunlight, 

dust or corrosive vapors such as bleach.

•  Locations exposed to vibrations, shocks or where it will be at an angle.

6. Specifications

Notes:
• These specifications are subject to change without notice.
• In the clinical validation study, K5 was used on 85 subjects for determination of 

diastolic blood pressure.

• This monitor is clinically investigated according to the requirements of 

EN ISO 81060-2:2014 and complies with EN ISO 81060-2:2014 and 
EN ISO 81060-2:2019 + A1:2020 (excluding pregnant and pre-eclampsia 
patients).

• This device has been validated for use on pregnant and pre-eclampsia patients 

according to the Modified European Society of Hypertension Protocol*.

• IP classification is degrees of protection provided by enclosures in accordance 

with IEC 60529. This device is protected against solid foreign objects of 12.5 mm 
diameter and greater such as a finger, and against oblique falling water drops 
which may cause issues during a normal operation.

• This device can be used for continuous operation.

• This blood pressure monitor is designed according to the European Standard 

EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and 
Part 3: Supplementary requirements for electromechanical blood pressure 
measuring systems.

• Hereby, OMRON HEALTHCARE Co., Ltd., declares that the radio equipment 

type EVOLV (HEM-7600T-E) is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following 
internet address: www.omron-healthcare.com

• This OMRON product is produced under the strict quality system of OMRON 

HEALTHCARE Co., Ltd., Japan. The Core component for OMRON blood 
pressure monitors, which is the Pressure Sensor, is produced in Japan.

• Please report to the manufacturer and the competent authority of the Member 

State in which you are established about any serious incident that has occurred 
in relation to this device.

Use this monitor only in the member countries of EU or the country you purchased 
it in. If you use it elsewhere, you may violate the radio laws or regulations of that 
country.

7. Trademarks

The 

Bluetooth

®

 

word mark and logos are registered 

trademarks owned by Bluetooth SIG, Inc. and any use of such 
marks by OMRON HEALTHCARE Co., Ltd. is under license. 
Other trademarks and trade names are those of their 
respective owners.

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and 
other countries. App Store is a service mark of Apple Inc.
Android, the Google Play logo are trademarks of Google Inc.

8. Limited Warranty

Thank you for buying an OMRON product. This product is constructed of high 
quality materials and great care has been taken in its manufacturing. It is designed 
to give you every satisfaction, provided that it is properly operated and maintained 
as described in the instruction manual.
This product is guaranteed by OMRON for a period of 3 years after the date of 
purchase. The proper construction, workmanship and materials of this product is 
guaranteed by OMRON. During this period of guarantee OMRON will, without 
charge for labour or parts, repair or replace the defect product or any defective 
parts.
The guarantee does not cover any of the following:
a. Transport costs and risks of transport.
b. Costs for repairs and / or defects resulting from repairs done by unauthorised 

persons.

c. Periodic check-ups and maintenance.
d. Failure or wear of optional parts or other attachments other than the main 

device itself, unless explicitly guaranteed above.

e. Costs arising due to non-acceptance of a claim (those will be charged for).
f. Damages of any kind including personal caused accidentally or from misuse.
g. Calibration service is not included within the guarantee.

Should guarantee service be required please apply to the dealer whom the 
product was purchased from or an authorised OMRON distributor. For the address 
refer to the product packaging / literature or to your specialised retailer.
If you have difficulties in finding OMRON customer services, contact us for 
information.
omron-healthcare.com

Repair or replacement under the guarantee does not give rise to any extension or 
renewal of the guarantee period.
The guarantee will be granted only if the complete product is returned together 
with the original invoice / cash ticket issued to the consumer by the retailer.

9. Some Useful Information about Blood Pressure

What is Blood Pressure?

Blood pressure is a measure of the force of blood flowing against the walls of the 
arteries. Arterial blood pressure is constantly changing during the course of the 
heart’s cycle.
The highest pressure in the cycle is called the Systolic Blood Pressure; the lowest 
is the Diastolic Blood Pressure. Both pressures, the Systolic and Diastolic, are 
necessary to enable a physician to evaluate the status of a patient’s blood 
pressure.

What is Arrhythmia?

Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in 
the bio-electrical system that drives the heartbeat. Typical symptoms are skipped 
heartbeats, premature contraction, an abnormally rapid (tachycardia) or slow 
(bradycardia) pulse.

Why is it a Good Thing to measure Blood Pressure at Home?

Many factors such as physical activity, 
anxiety, or the time of day, can influence 
your blood pressure. A single measurement 
may not be sufficient for an accurate 
diagnosis.
Thus it is best to try and measure your 
blood pressure at the same time each day, 
to get an accurate indication of any 
changes in blood pressure. Blood pressure is typically low in the morning and 
increases from afternoon to evening. It is lower in the summer and higher in the 
winter.

How is Hypertension related to Stroke?

Hypertension (high blood pressure) is the key risk factor for Stroke.
It is estimated that amongst hypertensive patients, effective treatment would 
prevent 1 in 4 haemorrhagic strokes (bleeding around the brain).
Hypertension guidelines have endorsed the use of Home Blood Pressure 
Monitoring in addition to the measurements in physicians’ offices to help manage 
hypertension effectively.

References to above medical claims are available upon request.

Error Display

Cause

Solution

Irregular heartbeat is 
detected.

Remove the arm cuff. Wait 
2 - 3 minutes and then take 
another measurement. 
Repeat the steps in section 
3.1. If this error continues to 
appear, contact your 
physician.

Movement during 
measurement.

Carefully read and repeat the 
steps in section 3.3.

Arm cuff is applied 
too loosely.

Apply the arm cuff tighter.
Refer to section 3.1.

The batteries are 
low.

Recommend replacement of 
all 4 batteries with new ones.
Refer to section 2.1.

The batteries are 
depleted or battery 
polarities are not 
properly aligned. 

Immediately replace 
4 batteries with new ones.
Refer to section 2.1.

Confirm the batteries are 
properly inserted with 
polarities correctly aligned. 
Refer to section 2.1.

Connection failure. 
Data is not being 
transmitted.

Refer to “Connection failure. 
Data is not being 
transmitted.” in section 4.2.

Arm cuff is applied 
too loosely.

Apply the arm cuff tighter.
Refer to section 3.1.

The arm cuff was 
inflated exceeding 
the maximum 
allowable pressure, 
and then deflated 
automatically.

Do not touch the arm cuff 
while taking a measurement. 
Refer to section 3.3.

Movement during 
measurement.

Repeat measurement. 
Remain still and do not talk 
during measurement.
Refer to section 3.3.

Clothing is interfering 
with the arm cuff.

Remove any clothing 
interfering with the arm cuff.
Refer to section 3.1.

Movement during 
measurement.

Repeat measurement.
Remain still and do not talk 
during measurement.
Refer to section 3.3.

Arm cuff is not 
applied correctly.

Apply the arm cuff correctly.
Refer to section 3.1.

* : “XX” will change to 

display an error 
number, 6 and 
higher.

Device error.

Contact your local OMRON 
representative.

Problem

Cause and Solution

No power.
No display appears on the 
monitor.

Replace all batteries with new ones.
Check the battery installation for proper 
placement of the battery polarities.
Refer to section 2.1.

Measurement values appear 
too high or too low.

Blood pressure varies constantly. Many 
factors including stress, time of day, and how 
you apply the arm cuff, may affect your blood 
pressure. 
Review the section, 3.2 and 3.3.

Connection failure. / 
Data is not being transmitted.

The blood pressure monitor might not be 
properly placed within the smart device's 
transmission range and is too far from the 
smart device. If there are no causes of data 
transmission interference found near the 
blood pressure monitor, move the blood 
pressure monitor within 5 m (16 ft.) of the 
smart device and try again.

The 

Bluetooth

 feature of the smart device 

is turned off. Turn on the 

Bluetooth

 feature 

of the smart device and your monitor, and try 
sending the data again.

The 

Bluetooth

 feature of the blood 

pressure monitor is turned off. 
Refer to “To turn “ON” the 

Bluetooth

” in 

“3.4 Turning “OFF” the 

Bluetooth

”.

The blood pressure monitor did not pair 
successfully to the smart device. Try to pair 
the devices again. 
Refer to “Pairing Your Monitor with a Smart 
Device” in section 2.2.
For more detail, go to “Help” in the “OMRON 
connect” app.

The application on the smart device is not 
ready. Check the application then try sending 
the data again. 
Refer to “Pairing Your Monitor with a Smart 
Device” in section 2.2. If the “Err” symbol still 
displays after checking the application, 
contact your OMRON retail outlet or 
distributor. Confirm your smart device 
compatibility with this monitor at 
omronconnect.com

*

®

®

®

®

®

Product category 

Electronic Sphygmomanometers

Product description

Automatic Upper Arm Blood Pressure Monitor

Model (code)

EVOLV (HEM-7600T-E)

Display

OLED display

Cuff pressure range

Pressure: 0 to 299 mmHg

Measurement range

Pressure: 40 to 260 mmHg
Pulse: 40 to 180 beats / min.

Accuracy

Pressure: ±3 mmHg
Pulse: ±5% of display reading

Inflation

Fuzzy-logic controlled by electric pump

Deflation

Automatic rapid deflation

Measurement method

Oscillometric method

Transmission method

Bluetooth

®

 low energy technology

Wireless communication

Frequency range: 2.4 GHz (2400 - 2483.5 MHz)
Modulation: GFSK
Effective radiated power: <20 dBm

IP classification

IP 22

Power source

4 “AAA” batteries 1.5V

Battery life

Approximately 300 measurements
(using new alkaline batteries)

Rating

DC6V 4W

Durable period (Service life)

Monitor: 5 years

Operating conditions

10°C to 40°C / 15 to 90% RH (non-condensing) / 
800 to 1060 hPa

Storage / Transport 
conditions

-20°C to 60°C / 10 to 90% RH (non-condensing) 

Weight

Monitor: Approximately 240 g

(not including batteries)

Dimensions

Monitor: Approximately 85 mm 

×

 120 mm 

×

 20 mm

(not including the arm cuff)

Arm circumference

22 to 42 cm

Contents

Monitor, battery set, instruction manual, setup instructions, 
storage case

Applied part

Type BF (Cuff)

Protection against electric 
shock 

Internally powered ME equipment 

* Topouchian J et al. 

Vascular Health and Risk Management 
2018:14 189–197

Symbols description

Applied part - Type BF
Degree of protection against electric shock 
(leakage current)
Class II equipment. Protection against 
electric shock
Ingress protection degree provided by 
IEC 60529

CE Marking

Metrology symbol

Symbol of Eurasian Conformity

Serial number

LOT number

Medical device

Temperature limitation

Humidity limitation

Atmospheric pressure limitation

Indication of connector polarity 

For indoor use only 

 or 

OMRON’s trademarked technology for blood 
pressure measurement

Identifier of cuffs compatible for the device

Cuff positioning indicator for the left arm

Marker on the cuff to be positioned above the 
artery

Range pointer and brachial artery alignment 
position

 or 

Manufacturer's quality control mark

Not made with natural rubber latex

Range indicator of arm circumferences to 
help selection of the correct cuff size.
Need for the user to consult this instruction 
manual.

Need for the user to follow this instruction 
manual thoroughly for your safety.

Direct current
Alternating current

Date of manufacture

Technology by OMRON Healthcare in Japan

To indicate generally elevated, potentially 
hazardous, levels of non-ionizing radiation, or 
to indicate equipment or systems e.g. in the 
medical electrical area that include RF 
transmitters or that intentionally apply RF 
electromagnetic energy for diagnosis or 
treatment.

Arm circumference

Wrist circumference

OMRON connect - App for uploading 
measurement data to smart device. 

Important information regarding Electromagnetic Compatibility (EMC)

HEM-7600T-E manufactured by OMRON HEALTHCARE Co., Ltd. conforms 
to EN60601-1-2:2015 Electromagnetic Compatibility (EMC) standard.
Further documentation in accordance with this EMC standard is available at 
OMRON HEALTHCARE EUROPE at the address mentioned in this 
instruction manual or at www.omron-healthcare.com
Refer to the EMC information for HEM-7600T-E on the website.

About a wireless communication interference

This Product operates in the unlicensed ISM band at 2.4GHz. In case this 
Product is used around the other wireless devices including microwave and 
wireless LAN, which operate same frequency band of this Product, there is a 
possibility that interference occurs between this Product and such other 
devices. If such interference occurs, please stop the operation of other 
devices or relocate this Product before using this Product or do not use this 
Product around the other wireless devices.

IP XX

or

or

or

or

or

or

INDEX

Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)

This marking shown on the product or its literature, indicates 
that it should not be disposed of, with other household wastes 
at the end of its working life. To prevent possible harm to the 
environment or human health from uncontrolled waste 
disposal, please separate this product from other types of 
wastes and recycle it responsibly to promote the sustainable reuse of material 
resources.

Household users should contact either the retailer where they purchased this 
product, or their local government office, for details of where and how they 
can return this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and 
conditions of the purchase contract. This product should not be mixed with 
other commercial waste for disposal. 

Example: fluctuation within a day (male, 35 years old)

mmHg

200

150

100

50

6

12

18

24

Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure

Time of day

Manufacturer

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, KYOTO,
617-0002 JAPAN

EU-representative

OMRON HEALTHCARE EUROPE B.V.

Scorpius 33, 2132 LR Hoofddorp, 
THE NETHERLANDS
www.omron-healthcare.com

Importer in EU

Production facility

OMRON HEALTHCARE Co., Ltd.

Matsusaka Factory
1855-370, Kubo-cho, Matsusaka-shi,
Mie, 515-8503 Japan

Subsidiaries

OMRON HEALTHCARE UK LTD.

Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, UK
www.omron-healthcare.com

OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH

Konrad-Zuse-Ring 28, 68163 Mannheim, GERMANY
www.omron-healthcare.com

OMRON SANTÉ FRANCE SAS

3, Parvis de la Gare, 94130 Nogent-sur-Marne, FRANCE
www.omron-healthcare.com

Made in Japan

9545878-0F_IM-HEM-7600T-E-EN-05-04-2021.fm  Page 2  Tuesday, July 6, 2021  12:13 PM

Summary of Contents for EVOLV

Page 1: ...esult in minor or moderate injury to the user or patient or damage to the equipment or other property Stop using this monitor and consult your physician if you experience skin irritation or discomfort...

Page 2: ...25 less or 25 more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure If the irregular heartbeat symbol displays with your measurement results w...

Page 3: ...ordance with the national local regulations for the disposal of batteries 2 2 Pairing Your Monitor with a Smart Device The date and time on your monitor will automatically be set when you pair it with...

Page 4: ...ff Remain still and do not talk while taking a measurement This device will store 100 measurements in the device Stored measurements cannot be viewed on the monitor s display You will need to use the...

Page 5: ...e use of wireless equipment is prohibited On aircraft In hospitals While abroad Your blood pressure monitor comes with the Bluetooth already turned on 1 Turn your monitor power off if it is turned on...

Page 6: ...ent Refer to section 3 3 Arm cuff is not applied correctly Apply the arm cuff correctly Refer to section 3 1 XX will change to display an error number 6 and higher Device error Contact your local OMRO...

Page 7: ...used for continuous operation This blood pressure monitor is designed according to the European Standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary req...

Page 8: ...e Technology by OMRON Healthcare in Japan To indicate generally elevated potentially hazardous levels of non ionizing radiation or to indicate equipment or systems e g in the medical electrical area t...

Page 9: ...sure is constantly changing during the course of the heart s cycle The highest pressure in the cycle is called the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressures the...

Page 10: ...cility OMRON HEALTHCARE Co Ltd Matsusaka Factory 1855 370 Kubo cho Matsusaka shi Mie 515 8503 Japan Subsidiaries OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG UK www omron health...

Reviews: