background image

E9NC-TA0

Model
Control output
Display resolution
Connection method
Power supply voltage
Power consumption

Control output
Protection circuit
Ambient temperature 
range

Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight (packed state/sensor)
Materials

E9NC-TA0
2
Minimum 0.1μm
Communication Unit compatible wire-saving connector
Supplied from the connector through the communications units.
Power supply voltage 24V:Normal mode: 2040mW max.(Power consumption 85mA max.)
Eco function ON: 1800mW max.(Power consumption 75mA max.)
Eco function LO: 1920mW max.(Power consumption 80mA max.)
Please refer to the specification of a communication unit.
Power supply reverse polarity protection, output short-circuit protection
Operating: 1 to 2 amplifiers connected: 0℃ to 55℃, 3 to 10 amplifiers connected: 0℃ to 50℃, 
11 to 16 amplifiers connected: 0℃ to 45℃, 17 to 30 amplifiers connected: 0℃ to 40℃
Storage: -30℃ to 70℃ (with no icing or condensation)
Operating and storage: 35% to 85% RH (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz, 1 minute
10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X and  Y directions
150 m/s

2

, for 3 times each in X, Y and Z directions

Approx. 65 g/Approx. 25 g
Case and cover: Polycarbonate (PC)

10.

11.

12.

13.

Turn off the power supply, check whether the Communication 

Unit compatible wire-saving connector is short circuited or not, 

and then turn on the power supply again.

Enabling 4 to 13

500

Eco function LO

  e c %

  l%

Eco on

The indicators (white digital) turn OFF.

They turn ON for approx. 10 seconds and then turn OFF 

by button operation.
Eco Lo

They turn ON for approx. 10 seconds and then 

the indicators (white digital) turn ON 

with low brightness.

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 

codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 

limitations of use which apply to the Product. This information by itself is not 

sufficient for a complete determination of the suitability of the Product in 

combination with the end product, machine, system, or other application or 

use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

S

ee also Product catalog for Warranty and Limitation of Liability.

Oct, 2014

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.

Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Turn on the power supply again.

If the restoration fails, restart the settings.

If the problem still persists, it indicates a setting memory 

failure. Replace the Unit with a new one.

Reviews: