background image

8

E6C2-C

 

Incremental Rotary Encoder

Installation

Connection

E6C2-CWZ6C/-CWZ3E/-CWZ5B

E6C2-CWZ1X

Note:

Receiver: AM26LS32 equivalent

Connection Examples

H7ER Self-powered Tachometer

Applicable Model: E6C2-CWZ3E (with a resolution of 10 or 60 P/R)

H7BR Digital Counter

Applicable Model: E6C2-CWZ3E

H7CR-CW Digital Counter

Applicable Model: E6C2-CWZ6C

C200H-CT

@@

 High-speed Counter Unit

Applicable model: E6C2-CWZ6C
Typical model: C200H-CT001-V1

Note:

Apply the following connections if the power supply to the
E6C2-C is 5 or 24 V.
Phase A and Power Supply: 5 V to A19 and 24 V to B20
Phase B and Power Supply: 5 V to A17 and 24 V to B18

Applicable model: E6C2-CWZ5B
Typical model: C200H-CT021

Note:

Apply the following connections if the power supply to the
E6C2-C is 12 or 24 V.
Phase A and Power Supply: 12 V to A8/B8 and 24 V to A9/B9
Phase B and Power Supply: 12 V to A12/B12 and 24 V to A13/
B13
Phase Z and Power Supply: 12 V to A16/B16 and 24 V to A17/
B17

Color

Terminal

Brown

Power supply (+V

CC

)

Black

Output phase A

White

Output phase B

Orange

Output phase Z

Blue

0 V (common)

Color

Terminal

Brown

Power supply (+V

CC

)

Black

Output phase A

White

Output phase B

Orange

Output phase Z

Black/Red stripes

Output phase A

White/Red stripes

Output phase B

Orange/Red stripes

Output phase Z

Blue

0 V (common)

E6C2-CWZ3E

5 to 12 VDC

Brown

Black

Blue

H7ER Digital Tachometer

H7BR Digital Counter

+12 V

0 V

Brown

Black

Blue

White

E6C2-C

Shielded

E6C2-CWZ6C

Black
White

Blue

Brown

12 VDC 
(100 mA)

H7CR-CW

0 V

Encoder at 0 V

+12 V

0 V

Phase A

12-VDC power supply

+12 V

0 V

Phase B

Phase A

Phase B

+12 V

0 V

Phase A

12-VDC power supply

+12 V

0 V

Phase B

Phase Z

Phase Z

Phase Z

0 V

5 to 
24 VDC

Phase B

Phase B

Phase A

Phase A

Encoder at 0 V

Summary of Contents for E6C2-C

Page 1: ...ates a circuit protecting the E6C2 C from dam age resulting from the incorrect wiring of output thus ensuring ease of use 33 Smaller than E6C C The E6C2 C uses a high performance LED indicator custom...

Page 2: ...0 5 to 12 VDC Voltage output 10 20 30 40 50 60 100 200 300 360 400 500 600 E6C2 CWZ3E 720 800 1 000 1 024 1 200 1 500 1 800 2 000 5 VDC Line driver output 10 20 30 40 50 60 100 200 300 360 400 500 600...

Page 3: ...or output Voltage output NPN output Line driver output see note 2 Output capacity Applied voltage 30 VDC max Output current 35 mA max Residual voltage 0 4 V max at sink current of 35 mA Output current...

Page 4: ...20 mA max Black white orange Output signal Black Phase A White Phase B Orange Phase Z Brown Blue Main circuit 0 V 3 3 2 k 5 VDC 5 to 12 VDC 10 Ground Shielded E6C2 CWZ5B AM26LS31 or equivalent Black...

Page 5: ...L H Phase B L H Phase Z L T 360 CW 1 4 1 8T 90 45 H Phase A L H Phase B L H Phase Z L T 360 CCW 1 4 1 8T 90 45 Direction or resolution Clockwise CW As viewed from the end of the shaft Direction or res...

Page 6: ...2 insulator 1 0 dia five conductors and shield eight conductors for line driver use E69 C06B E69 C68B With Ends of Different Diameter Note The coupling is made of glass reinforced PBT 22 5 5 2 8 11 16...

Page 7: ...holes The flange is made of SPCC t 3 2 Four R3 25 2 0 05 0 dia hole Note Material SPCC t 3 2 Three 5 5 screw head holes Mounting Bracket A set of three Brackets provided with the E69 FCA02 Mounting Di...

Page 8: ...12 or 24 V Phase A and Power Supply 12 V to A8 B8 and 24 V to A9 B9 Phase B and Power Supply 12 V to A12 B12 and 24 V to A13 B13 Phase Z and Power Supply 12 V to A16 B16 and 24 V to A17 B17 Color Ter...

Page 9: ...Setup in the DM area Count Mode Applicable Model E6C2 CWZ6C Reset The present count value can be reset with the soft reset function or the AND of soft reset and phase Z input Output Up Down mode Incre...

Page 10: ...haft or coupling Therefore do not hit the shaft or coupling with a hammer when inserting the shaft into the coupling Refer to the following illustrations when using a standard coupling When connecting...

Page 11: ...5 M km min at 20 C The rise time varies with the resistance of the cord and the kind of cord as well as the length of the cord The residual output voltage will increase according to the length of the...

Page 12: ...s or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installa...

Reviews: