80
Reading Sets of Data
Section 2-3
2-3
Reading Sets of Data
Function
A single command block can make it possible to read the contents of all the
memory banks or control points, or the contents of all data codes.
Command
Designate A or AA for the set of memory bank data, control point data, or data
code of the command block to read the set of data. A or AA can be used only
once in the command block.
It is not possible to use A or AA only once in a command block (e.g., if A is
used for the memory bank data, it cannot be used for the control point data
and AA cannot be used for the data code).
Response
Use the following command format so that the contents of all the memory
banks can be read.
Use the following command format so that the contents of all the control
points can be read.
Bank
0 to 7
or A
00 to nn
or AA
Terminator
*
Header
code
@
Data code
Unit
s
00 to 0F
FCS
Control
point
0 to 7
or A
4 or 5 digits
Terminator
Header
code
@
Data of memory
bank 0
Unit
00 to 0F
*
Data of memory
bank 7
s
FCS
Data of memory
bank 1
4 or 5 digits
4 or 5 digits
End
code
4 or 5 digits
Terminator
Header
code
@
Data of control
point 0
Unit
00 to 0F
*
Data of control
point 7
s
FCS
Data of control
point 1
4 or 5 digits
4 or 5 digits
End
code