E5CSL/E5CWL

7

Safety Precautions

 

!

CAUTION

Precautions for Safe Use

Be sure to observe the following precautions to prevent operation 
failure, malfunction, or adverse affects on the performance and 
functions of the product. Not doing so may occasionally result in 
unexpected events.

1.

The product is designed for indoor use only. Do not use the 
product outdoors or in any of the following locations.

Places directly subject to heat radiated from heating equipment.

Places subject to splashing liquid or oil atmosphere.

Places subject to direct sunlight.

Places subject to dust or corrosive gas (in particular, sulfide gas 
and ammonia gas).

Places subject to intense temperature change.

Places subject to icing and condensation.

Places subject to vibration and large shocks.

2.

Use/store within the rated temperature and humidity ranges.
Provide forced-cooling if required.

3.

To allow heat to escape, do not block the area around the product.
Do not block the ventilation holes on the product.

4.

Be sure to wire properly with correct polarity of terminals.

5.

Use specified size (M3.5, width 7.2 mm or less) crimped terminals 
for wiring. To connect bare wires to the terminal block, use copper 
braided or solid wires with a rated temperature of over 70

°

C and a 

gauge of AWG24 to AWG14 (equal to a cross-sectional area of 
0.205 to 2.081 mm

2

). (The stripping length is 5 to 6 mm.) Up to two 

wires of same size and type, or two crimped terminals can be 
inserted into a single terminal.

6.

Do not wire the terminals which are not used.

7.

Allow as much space as possible between the controller and 
devices that generate a powerful high-frequency or surge.
Separate the high-voltage or large-current power lines from other 
lines, and avoid parallel or common wiring with the power lines 
when you are wiring to the terminals.

8.

Use this product within the rated load and power supply.

9.

Make sure that the rated voltage is attained within two seconds of 
turning ON the power using a switch or relay contact. If the voltage 
is applied gradually, the power may not be reset or output 
malfunctions may occur.

10.

Make sure that the Controller has 30 minutes or more to warm up 
after turning ON the power before starting actual control 
operations to ensure the correct temperature display.

11.

A switch or circuit breaker should be provided close to this unit.
The switch or circuit breaker should be within easy reach of the 
operator, and must be marked as a disconnecting means for this 
unit.

12.

Do not use paint thinner or similar chemical to clean with. Use 
standard grade alcohol.

13.

Design system (control panel, etc) considering the 2 second of 
delay that the controller’s output to be set after power ON.

14.

The output may turn OFF when shifting to certain levels. Take this 
into consideration when performing control.

15.

The number of non-volatile memory write operations is limited.

Do not touch the terminals while power is being 
supplied.
Doing so may occasionally result in minor injury due to 
electric shock.

Do not allow pieces of metal, wire clippings, or fine 
metallic shavings or filings from installation to enter the 
product. Doing so may occasionally result in electric 
shock, fire, or malfunction.

Do not use the product where subject to flammable or 
explosive gas. Otherwise, minor injury from explosion 
may occasionally occur.

Never disassemble, modify, or repair the product or 
touch any of the internal parts. Minor electric shock, fire, 
or malfunction may occasionally occur.

If the output relays are used past their life expectancy, 
contact fusing or burning may occasionally occur. 
Always consider the application conditions and use the 
output relays within their rated load and electrical life 
expectancy.
The life expectancy of output relays varies considerably 
with the output load and switching conditions.

Tighten the terminal screws to between 0.74 and 0.90 
N·m. Loose screws may occasionally result in fire.

Set the parameters of the product so that they are 
suitable for the system being controlled. If they are not
suitable, unexpected operation may occasionally result 
in property damage or accidents.

A malfunction in the Temperature Controller may 
occasionally make control operations impossible or 
prevent alarm outputs, resulting in property damage. To 
maintain safety in the event of malfunction of the 
Temperature Controller, take appropriate safety 
measures, such as installing a monitoring device on a 
separate line.

Summary of Contents for E5CSL

Page 1: ...At the end of this document you will find links to products related to this catalog You can go directly to our shop by clicking HERE HERE ...

Page 2: ... VDC 21 mA 2 Sensor type TC Thermocouple K J T R or S P Platinum resistance thermometer Pt100 Models with Dual Display 1 Control Output R Relay output 250 VAC 3 A Q Voltage output for driving SSR 12 VDC 21 mA 2 Alarm E5CWL only 1 Relay output 250 VAC 1 A resistive load 3 Sensor type TC Thermocouple K J T R or S P Platinum resistance thermometer Pt100 48 48 mm E5CSL 48 48 mm E5CWL Sensor Inputs The...

Page 3: ...E53 COV19 Model E53 COV20 Model Y92F 45 Power supply voltage 100 to 240 VAC 50 60 Hz Operating voltage range 85 to 110 of rated supply voltage Power con sumption E5CSL 3 5 VA E5CWL 3 5 VA Sensor input Models with thermocouple inputs Thermocouple K J T R or S Models with platinum resistance thermometer inputs Platinum resistance thermometer Pt100 Control output Relay output SPST NO 250 VAC 3 A resi...

Page 4: ...0 0 to 400 0 0 0 to 750 0 4 T 200 to 400 300 to 700 5 199 9 to 400 0 199 9 to 700 0 6 R 0 to 1 700 0 to 3 000 7 S 0 to 1 700 0 to 3 000 Model temperature input Set value Input type Range C F Pt input 8 Pt100 200 to 850 300 to 1500 9 199 9 to 500 0 199 9 to 900 0 Setting Alarm type Positive alarm value X Negative alarm value X 0 No alarm Output OFF 1 Deviation upper lower limit Always ON 2 Deviatio...

Page 5: ... input type Sampling period 250 ms Affect of signal source resistance Thermocouple 0 1 C Ω max 100 Ω max See note 2 Platinum resistance thermometer 0 6 C Ω max 10 Ω max Insulation resistance 20 MΩ min at 500 VDC Dielectric strength 2 300 VAC 50 or 60 Hz for 1 min between terminals with different charge Vibration resistance Malfunction 10 to 55 Hz 20 m s2 for 10 min each in X Y and Z directions Des...

Page 6: ...ection 2 These keys are disabled when starting and stopping operation has been disabled with operation control key protection 1 Display No 1 Displays the process value PV or parameter For the E5CSL the set point or parameter setting is also displayed 2 Display No 2 Displays the set point SP or parameter setting 3 Deviation Show the relation between the process value and the set point Indicators Li...

Page 7: ...minal Cover E53 COV19 Note The E53 COV10 cannot be used 48 48 4 8 Front Panel E53 COV20 Note 1 This Front Panel accessory is required to attach the Y92A 48B or Y92A 48D 2 This Front Panel accessory is only the frame It does not include the plastic cover Fixture Accessory 69 6 to 77 6 87 72 72 76 4 7 67 67 Y92F 45 72 x 72 48 x 48 2 7 62 8 78 87 Panel 1to8mm Mounted to E5CWL ...

Page 8: ...ller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 11 A switch or circuit breaker should be provided close to this unit The switch or circuit breaker should be within easy reach of the operator and must be marked as a disconnecting means for this unit 12 Do not use paint thinner or similar chemical t...

Page 9: ...low Sections without any specification on their degree of protection or those with IP 0 are not waterproof Front panel IP50 Rear case IP20 Terminal section IP00 Operating Precautions 1 It takes approximately two seconds for the outputs to turn ON from after the power supply is turned ON Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit 2 ...

Page 10: ...E5CSL E5CWL 9 ...

Page 11: ...E5CSL E5CWL 10 ...

Page 12: ...ED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitabili...

Page 13: ...73 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tow...

Page 14: ...ted delivery time enquiry in real time Logistics systems for the shipment of materials almost anywhere in the world Purchasing management order record and tracking of shipments To access the product click on the green button Product Code Reference Product link Timers hard plastic protective cover 48x48 156312 Y92A 48D Buy on EAN Temperature and Process Terminals cover E5CB 353953 E53 COV19 Buy on ...

Reviews: