background image

7

E3X-SD

Amplifier Units with Connectors

E3X-SD7
E3X-SD9

4.

3

 

8

 

10.7 

10

10

3

.4 

22.4 

4.4 

1

3

 

64.

3

64.

3

16 

16 

8

 

10.7 

3

 

12

8

.95

12

8

.95

3

 

12

8

.95

12

8

.95

16 

10

10

L

(9) 

3

.4 

3

1.5 

3

1.5 

(9) 

3

.4 

3

1.5 

3

1.5 

(9.4) 

1

8

9

3

.75 

9

3

.75 

10

10

15 

9

3

.75 

9

3

.75 

1

3

 

12.4 

3

0.4 

64.

3

 

64.

3

 

Oper

a

tion indic

a

tor 

Two,  
2.4 di

a

Two,  
2.4 di

a

Hole for optic

a

l comm

u

nic

a

tion

s

 

Center of DIN tr

a

ck 

DIN tr

a

ck  

(

s

old 

s

ep

a

r

a

tely) 

PFP-

@

Fi

b

er Att

a

chment mo

u

nted (E

3

9-F9) 

End Pl

a

te  

(

s

old 

s

ep

a

r

a

tely) 

PFP-M 

Mo

u

nting Br

a

cket (E

3

9-L14

3

)  

S

U

S3

04 

s

t

a

inle

ss

 

s

teel (

s

old 

s

ep

a

r

a

tely) 

Fi

b

er Att

a

chment mo

u

nted (E

3

9-F9) 

Two, M

3

 

Mountin

g

 Hole

s

 

With Mountin

g

 Bracket Attached 

Multiple connection dia

g

ram

DIN track mountin

g

Two, 

3

.2 di

a

.  hole

s

 

1

8

A di

a

12.95

Hole for optic

a

l comm

u

nic

a

tion

s

 

A di

a

12.95

 Cable Diameters

E3X-CN11 (3 conductors)

4.0 dia.

E3X-CN12 (1 conductor)

2.6 dia.

The number of 

expansion

L (mm)

1

10

2

20

3

30

4

40

5

50

6

60

7

70

8

80

9

90

10

100

Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side.

Summary of Contents for E3X-SD Series

Page 1: ...ion Amplifier Unit Connectors sold separately Note Stickers for Connectors are included as accessories Accessories sold separately Shape Item Order code NPN output PNP output Pre wired E3X SD21 2M E3X...

Page 2: ...thout other E3X series Amplifiers Ambient illumination Receiver side Incandescent lamp 10 000 lux max Sunlight 20 000 lux max Number of gang mounted Amplifiers 16 max The ambient temperature specifica...

Page 3: ...ut Operation indicator orange Photo electric Sensor main circuit Load 12 to 24 VDC 1 4 3 Incident light No incident light ON OFF ON OFF Operate Reset Between brown and black leads Operation indicator...

Page 4: ...caution when performing maintenance and washing Failure to do so may result in burn injury Do not use the product in atmospheres or environments that ex ceed product ratings Amplifier Units Designing...

Page 5: ...required after all the Master and Slave Connectors have been inserted 3 Attach the stickers provided as accessories to the sides of Master and Slave Connectors that are not connected to other Connect...

Page 6: ...DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel sold separately Fiber Attachment mounted E39 F9 Two M3...

Page 7: ...ed E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel sold separately Fiber Attachment mounted E39 F9 Two M3 Mounting Holes With Mounting Bracket Attached Multiple...

Page 8: ...of amplifier Slave Connector E3X CN12 7 2 000 50 0 E3X CN12 2 6 dia 2 6 dia cable 1 conductor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Edge of am...

Page 9: ...n the workpieces cannot be stopped Execute automatic teaching again if the inci dent light level is not automatically set to the optimal value Digital threshold value adjustment UP DOWN Teaching statu...

Page 10: ...e uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energ...

Page 11: ...11 E3X SD...

Page 12: ...interest of product improvement specifications are subject to change without notice Cat No E67E EN 01 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 568 13 00 Fax 31...

Reviews: