E3X-NH
E3X-NH
14
Protective cover
Unlocked
Locked
Disconnection
1. Before pulling out the fiber, you MUST first press the lock
button to release (unlock) the fiber, or you may damage
the fiber.
2. Then, pull the fiber from the amplifier.
2.2-mm-dia. Fiber
Thin Fiber with the E39-F9 Attachment
Fiber with Fixed Length
12.6 mm
Fiber Unit
Amplifier Unit
Insert to the portion
from the tip to the
insertion mark of
each fiber into the
Amplifier Unit.
Amplifier Unit
Fiber Unit
12.6 mm
The portion from the tip to
the insertion mark of each
fiber into the Amplifier Unit.
12.6 mm
Amplifier Unit
The portion from the tip to
the insertion mark of each
fiber into the Amplifier Unit.
Procedure for Inserting the Fiber
If the portion from the tip to the insertion mark of the fiber is
not inserted into the Amplifier Unit, the sensing distance will
be reduced.
J
BENDING RADIUS
E39-F11 Sleeve Bender
The bending radius of the stainless tube should be as large as
possible. The smaller the bending radius becomes, the shorter
the sensing distance will be.
Insert the tip of the stainless tube to the Sleeve Bender and bend
the stainless tube slowly along the curve of the Sleeve Bender
(refer to the figure).
Fiber tip position mark
Do not bend here.
1.2 dia.
max.
1.3 dia.
min.
1.2 dia.
max.
R 12.5
R 7.5
R 10
R 5
Stainless tube
90
o
max.
10
10
J
REFLECTOR
Observe the Following Precautions when Using the
Reflector (E39-R3)
Use detergent, etc., to remove any dust or oil from the surfaces
where tape is applied. Adhesive tape will not be attached
properly if oil or dust remains on the surface.
The E39-R3 cannot be used in places where it is exposed to oil
or chemicals.