Ratings and Specifications

Amplifier Units

* Models with connectors have a dielectric strength of 500 VAC. 

Amplifier Unit Connectors

Type

Digital display and direct key setting

Standard models

Item

Model

E3X-SD

@

Light source (wavelength)

Red LED (620 nm)

Power supply voltage

12 to 24 VDC 

±

10%, ripple (p-p): 10% max.

Current consumption

960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.)

Control output

Open-collector output (NPN or PNP) 
Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.)
Light-ON/Dark-ON mode selector

Response time

Operate or reset: 200 

μ

s max.

Sensitivity adjustment

UP/DOWN direct key setting, teaching

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection

Timer function

ON/OFF-delay timer: 10 ms (each fixed)

Mutual interference 
prevention

Up to 5 Amplifiers (optically synchronized)

Ambient illumination

Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.

Ambient temperature range

Operating: Groups of 1 to 3 Amplifiers: 

25

°

C to 55

°

C

Groups of 4 to 11 Amplifiers: 

25

°

C to 50

°

C

Groups of 12 to 16 Amplifiers:

25

°

C to 45

°

C

Storage: 

30

°

C to 70

°

C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 M

Ω

. min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 minute (*)

Vibration resistance

Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions

Shock resistance

Destruction: 500 m/s

2

, for 3 times each in X, Y and Z directions

Degree of protection

IEC 60529 IP50 (with Protective Cover attached)

Connection method

Pre-wired (standard cable length: 2 m), or connector

Weight (packed state)

Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g

Material

Case

Polybutylene terephthalate (PBT)

Cover

Polycarbonate

Accessories

Instruction manual

Item

Model

E3X-CN11

Rated current

2.5 A

Rated voltage

50 V

Contact resistance

20 m

Ω

 max. (20 mVDC max., 100 mA max.)

(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance 
of the cable.)

Number of insertions

Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)

Material

Housing

Polybutylene terephthalate (PBT)

Contact

Phosphor bronze/gold-plated nickel

Weight (packed state)

Approx. 55 g

Summary of Contents for E3X-CN11

Page 1: ...Stickers for Connectors are included as accessories Item Appear ance Cable length No of conductors Model Master Connector 2 m 3 E3X CN11 Slave Connector 1 E3X CN12 Combining Amplifier Units and Conne...

Page 2: ...o 11 Amplifiers 25 C to 50 C Groups of 12 to 16 Amplifiers 25 C to 45 C Storage 30 C to 70 C with no icing or condensation Ambient humidity range Operating and storage 35 to 85 with no condensation In...

Page 3: ...dels Reflective Fiber Units Size 15 10 3 mm Flat and flexible fiber models are easy to mount and will not break 20 mm Flat View E32 D15ZR Flexible fiber Conventional fiber Cladding Cores No Breaking F...

Page 4: ...0 E39 F1 3000 E32 T11R E39 F1 2100 E32 T11 E39 F1 2000 E32 T14 1800 E32 T11L E32 T12L 700 E32 T11L E39 F2 500 E32 T11R E39 F2 220 E32 T11 E39 F2 360 E32 T21L E32 T22L 200 Ultracompact ultrafine sleeve...

Page 5: ...xial small spot E32 CC200R 75 E32 CC200 150 E32 D32L 80 E32 C31 E32 D32 40 E32 C42 E39 F3A Spot diameter of 0 1 to 0 6 mm at 6 to 15 mm E32 D32 E39 F3A Spot diameter of 0 5 to 1 mm at 6 to 15 mm E32 C...

Page 6: ...eration indicator orange Between brown and black leads Output transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Reset Operation indicator orange Between blue and black lea...

Page 7: ...atmospheres or environments that exceed product ratings 6 Do not wire the product incorrectly such as using incorrect power supply polarity 7 Connect the load properly 8 Do not short circuit both end...

Page 8: ...ection and Disconnection The E3X Amplifier Unit has a lock lever Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures 1 Connection Open the Protective Cove...

Page 9: ...eparated press down on the lever on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Mounting End Plate PFP M Depending on how i...

Page 10: ...s Center of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 T...

Page 11: ...enter of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 Two...

Page 12: ...lator diameter 1 1 mm Edge of amplifier Slave Connector E3X CN12 7 2 000 50 0 E3X CN12 2 6 dia 2 6 dia cable 1 conductor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator...

Page 13: ...Description 999 10 times 110 min Stable incident light 100 90 to 110 Unstable incident light or Unstable interrupted light 0 90 max Stable interrupted light Displays 1 Operation indicator Excess gain...

Page 14: ...MEMO 14...

Page 15: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control sys...

Page 16: ...ed OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V...

Page 17: ...00E E32 T14L E32 CC200 E32 DC200 E32 TC200A E32 C42 E32 D11R E32 D12 E32 D12F E32 D14L E32 D73 E32 DC200B E32 DC200B4 E32 DC200F E32 DC200F4 E32 G14 E32 L25 E32 L25A E32 L25L E32 R21 E32 T11L E32 T14...

Reviews: