background image

1

Simple Fiber Amplifier

E3X-SD

The Standard for Fiber Amplifiers with 
Simple Operation and High Performance

Operation so simple that essentially anyone can use the 

amplifier right way.

Immediately determine operation and amount of light with a 

simple, bright display.

General-purpose capabilities to simply handle a broad range of 

applications.

Ordering Information

Sensor I/O Connectors (Order Separately)

Accessories (Order Separately)

Amplifier Units

Digital Display and Direct Key Setting 

Item

Appearance

Connection 

method

Ratings and 

Specifications

Model

NPN 

output

PNP 

output

Standard 
models

Pre-wired

---

E3X-SD11 E3X-SD41

Wire-saving 
connector

E3X-SD6 E3X-SD8

Amplifier Unit Connectors (Order Separately)   

Note:

 Stickers for Connectors are included as accessories.

Item

Appear-

ance

Cable 

length

No. of 

conductors

Model

Master 
Connector

2 m

3

E3X-CN11

Slave 
Connector

1

E3X-CN12

Combining Amplifier Units and 
Connectors

Amplifier Units

Applicable Connectors (Order Separately)

Type

NPN

PNP

+

Master Connector

Slave Connector

(Basically, Amplifier Units and Connectors are sold 
separately)
Refer to the following tables when placing an order.

Standard

models

E3X-SD6

E3X-SD8

E3X-CN11 (3-wire)

E3X-CN12 (1-wire)

When Using 5 Amplifier Units

5 Amplifier Units

+

1 Master Con 4 Slave Connectors

Size

Cable specifications

Appearance

Cable type

Model

M8

Standard cable

2 m

Four-
conductor
cable

XS3F-M421-402-A

5 m

XS3F-M421-405-A

2 m

XS3F-M422-402-A

5 m

XS3F-M422-405-A

Straight 
connector

L-shaped
connector

Mounting Brackets

Appearance

Applicable models

Model

Quantity

E3X-SD

@

E39-L143

1

End Plate

Appearance

Model

Quantity

PFP-M

1

Summary of Contents for E3X-CN11

Page 1: ...Stickers for Connectors are included as accessories Item Appear ance Cable length No of conductors Model Master Connector 2 m 3 E3X CN11 Slave Connector 1 E3X CN12 Combining Amplifier Units and Conne...

Page 2: ...o 11 Amplifiers 25 C to 50 C Groups of 12 to 16 Amplifiers 25 C to 45 C Storage 30 C to 70 C with no icing or condensation Ambient humidity range Operating and storage 35 to 85 with no condensation In...

Page 3: ...dels Reflective Fiber Units Size 15 10 3 mm Flat and flexible fiber models are easy to mount and will not break 20 mm Flat View E32 D15ZR Flexible fiber Conventional fiber Cladding Cores No Breaking F...

Page 4: ...0 E39 F1 3000 E32 T11R E39 F1 2100 E32 T11 E39 F1 2000 E32 T14 1800 E32 T11L E32 T12L 700 E32 T11L E39 F2 500 E32 T11R E39 F2 220 E32 T11 E39 F2 360 E32 T21L E32 T22L 200 Ultracompact ultrafine sleeve...

Page 5: ...xial small spot E32 CC200R 75 E32 CC200 150 E32 D32L 80 E32 C31 E32 D32 40 E32 C42 E39 F3A Spot diameter of 0 1 to 0 6 mm at 6 to 15 mm E32 D32 E39 F3A Spot diameter of 0 5 to 1 mm at 6 to 15 mm E32 C...

Page 6: ...eration indicator orange Between brown and black leads Output transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Reset Operation indicator orange Between blue and black lea...

Page 7: ...atmospheres or environments that exceed product ratings 6 Do not wire the product incorrectly such as using incorrect power supply polarity 7 Connect the load properly 8 Do not short circuit both end...

Page 8: ...ection and Disconnection The E3X Amplifier Unit has a lock lever Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures 1 Connection Open the Protective Cove...

Page 9: ...eparated press down on the lever on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Mounting End Plate PFP M Depending on how i...

Page 10: ...s Center of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 T...

Page 11: ...enter of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 Two...

Page 12: ...lator diameter 1 1 mm Edge of amplifier Slave Connector E3X CN12 7 2 000 50 0 E3X CN12 2 6 dia 2 6 dia cable 1 conductor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator...

Page 13: ...Description 999 10 times 110 min Stable incident light 100 90 to 110 Unstable incident light or Unstable interrupted light 0 90 max Stable interrupted light Displays 1 Operation indicator Excess gain...

Page 14: ...MEMO 14...

Page 15: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control sys...

Page 16: ...ed OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V...

Page 17: ...00E E32 T14L E32 CC200 E32 DC200 E32 TC200A E32 C42 E32 D11R E32 D12 E32 D12F E32 D14L E32 D73 E32 DC200B E32 DC200B4 E32 DC200F E32 DC200F4 E32 G14 E32 L25 E32 L25A E32 L25L E32 R21 E32 T11L E32 T14...

Reviews: